High-efficient white blood cell separation from whole blood using cascaded inertial microfluidics

被引:3
|
作者
Cha, Haotian [1 ]
Kang, Xiaoyue [2 ]
Yuan, Dan [2 ]
de Villiers, Belinda [3 ]
Mak, Johnson [3 ]
Nam-Trung Nguyen [1 ]
Zhang, Jun [1 ,4 ]
机构
[1] Griffith Univ, Queensland Micro & Nanotechnol Ctr, Nathan, Qld 4111, Australia
[2] Univ Queensland, Sch Mech & Min Engn, Brisbane, Qld 4072, Australia
[3] Griffith Univ, Inst Glyc, Gold Coast, Australia
[4] Griffith Univ, Sch Engn & Built Environm, Nathan, Qld 4111, Australia
基金
澳大利亚研究理事会;
关键词
HIGH-THROUGHPUT; PLASMA; CLASSIFICATION; EXTRACTION; CHIP;
D O I
10.1016/j.talanta.2024.127200
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
White blood cells (WBCs) are a crucial component of the human immune system. WBCs contain invaluable information about the health status of the human body. Therefore, separating WBCs is indispensable for the diagnosis of many diseases in clinical setting. The low ratio of WBCs to red blood cells in whole blood has made the isolation of WBCs challenging. As the conventional single-stage microfluidic technology cannot provide sufficient separation purity. We used a cascaded inertial microfluidic chip by consecutively connecting two sinusoidal channels to enhance the purity of WBCs after single processing. The improvement was in part due to the diversion of the sample at the end of the first stage separation, resulting in a lower flow rate in the second stage of processing within the cascaded device. We embedded concave micro-obstacles in sinusoidal channels to adjust their effective working flow rate range and enable the proper operation of both channels simultaneously. Using polystyrene beads mixture (5 and 10 mu m) with a primary ratio of 1000 to 1, a single processing step through our cascaded chip improved the purity of 10-mu m particles with more than three orders of magnitude of enrichment (from 0.08 % to 99.83 %) with a flow rate of 560 mu L/min (Re = 77). Using diluted whole blood ( x 1/10), we achieved 307-fold enrichment of WBCs (0.14 %-43.017 %) in a single process which was accompanied with similar to 3 orders of magnitude background removal of RBCs (from 4.8 x 10(8) to 5.7 x 10(5) counts/mL). This cascaded manner chip has the capacity to achieve high-efficiency separation of blood cells for clinical diagnosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] High-Throughput Separation of White Blood Cells From Whole Blood Using Inertial Microfluidics
    Zhang, Jun
    Yuan, Dan
    Sluyter, Ronald
    Yan, Sheng
    Zhao, Qianbin
    Xia, Huanming
    Tan, Say Hwa
    Nam-Trung Nguyen
    Li, Weihua
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2017, 11 (06) : 1422 - 1430
  • [2] Inertial microfluidics combined with selective cell lysis for high throughput separation of nucleated cells from whole blood
    Ramachandraiah, Harisha
    Svahn, Helene A.
    Russom, Aman
    RSC ADVANCES, 2017, 7 (47): : 29505 - 29514
  • [3] High-Throughput White Blood Cell (Leukocyte) Enrichment from Whole Blood Using Hydrodynamic and Inertial Forces
    Lombodorj, Batzorig
    Tseng, Horas Cendana
    Chang, Hwan-You
    Lu, Yen-Wen
    Tumurpurev, Namnan
    Lee, Chun-Wei
    Ganbat, Batdemberel
    Wu, Ren-Guei
    Tseng, Fan-Gang
    MICROMACHINES, 2020, 11 (03)
  • [4] High-throughput rare cell separation from blood samples using steric hindrance and inertial microfluidics
    Shen, Shaofei
    Ma, Chao
    Zhao, Lei
    Wang, Yaolei
    Wang, Jian-Chun
    Xu, Juan
    Li, Tianbao
    Pang, Long
    Wang, Jinyi
    LAB ON A CHIP, 2014, 14 (14) : 2525 - 2538
  • [5] Elasto-inertial microfluidics for bacteria separation from whole blood for sepsis diagnostics
    Muhammad Asim Faridi
    Harisha Ramachandraiah
    Indradumna Banerjee
    Sahar Ardabili
    Sergey Zelenin
    Aman Russom
    Journal of Nanobiotechnology, 15
  • [6] Elasto-inertial microfluidics for bacteria separation from whole blood for sepsis diagnostics
    Faridi, Muhammad Asim
    Ramachandraiah, Harisha
    Banerjee, Indradumna
    Ardabili, Sahar
    Zelenin, Sergey
    Russom, Aman
    JOURNAL OF NANOBIOTECHNOLOGY, 2017, 15
  • [7] Label-Free Cancer Cell Separation from Human Whole Blood Using Inertial Microfluidics at Low Shear Stress
    Lee, Myung Gwon
    Shin, Joong Ho
    Bae, Chae Yun
    Choi, Sungyoung
    Park, Je-Kyun
    ANALYTICAL CHEMISTRY, 2013, 85 (13) : 6213 - 6218
  • [8] High resolution and rapid separation of bacteria from blood using elasto-inertial microfluidics
    Narayana Iyengar, Sharath
    Kumar, Tharagan
    Martensson, Gustaf
    Russom, Aman
    ELECTROPHORESIS, 2021, 42 (23) : 2538 - 2551
  • [9] HIGH-THROUGHPUT WHITE BLOOD CELLS (LEUKOCYTES) SEPARATION AND ENRICHMENT FROM WHOLE BLOOD BY HYDRODYNAMIC AND INERTIAL FORCE
    Tseng, Horas-Cendana
    Wu, Ren-Guei
    Chang, Hwan-You
    Tseng, Fan-Gang
    2012 IEEE 25TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2012,
  • [10] Soft inertial microfluidics for high throughput separation of bacteria from human blood cells
    Wu, Zhigang
    Willing, Ben
    Bjerketorp, Joakim
    Jansson, Janet K.
    Hjort, Klas
    LAB ON A CHIP, 2009, 9 (09) : 1193 - 1199