Sensitive and Facile Detection of Vitamin D Based on Fluorescent Labeled Aptamer Probe and Exonuclease I-Assisted Signal Amplification

被引:0
|
作者
Xu, Xinqiu [1 ,2 ]
Jia, Chaofan [2 ,4 ]
Zhang, Fengjiao [1 ,2 ]
Li, Hao [3 ]
Gong, Weilei [2 ]
Wang, Changqin [2 ]
Wei, Yin [2 ]
机构
[1] Shandong First Med Univ & Shandong Acad Med Sci, Sch Publ Hlth, Jinan, Shandong, Peoples R China
[2] Jining Med Univ, Sch Publ Hlth, Jining, Peoples R China
[3] Jining Med Coll, Sch Publ Hlth, Key Lab Food Nutr & Safety, Jining, Peoples R China
[4] Binzhou Med Univ, Sch Publ Hlth, Yantai, Peoples R China
关键词
Vitamin D3; Aptamer; Fullerenes; Fluorescence; APTASENSOR; QUANTIFICATION; ASSAY; C-60;
D O I
10.1007/s10895-025-04282-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study presents a rapid, simple aptamer-based fluorescence sensor using fullerenes as a quencher for detecting vitamin D3. Fullerenes, with its pi-electron cloud, acts as a powerful electron acceptor, facilitating F & ouml;rster resonance energy transfer (FRET) from carboxyfluorescein (FAM). The aptamer, labeled with 5 ' 6-FAM, adsorbs onto the fullerenes surface through hydrogen bonding and pi-pi stacking interactions, leading to fluorescence quenching. Upon vitamin D3 binding, the aptamer forms a hairpin structure that prevents adsorption onto the fullerenes surface, restoring fluorescence. The fullerenes were characterized using UV-Vis, FT-IR, Raman spectroscopy, SEM, TEM, and zeta potential measurements. The sensor's response to varying vitamin D3 concentrations was analyzed with a fluorescence spectrometer, revealing a linear detection range of 0-600 nM and a detection limit of 200 nM, which improved to 50 nM with exonuclease I. The sensor demonstrated a recovery rate of 88.4%-96.3% for vitamin D3 in water samples, confirming its feasibility for practical applications. In addition, our proposed sensor exhibited good repeatability (3.27%) and stability (90%). The innovative use of fullerenes as a fluorescence quencher, along with the aptamer's specific binding to vitamin D3, provides a novel and highly sensitive avenue for vitamin D3 detection.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Rapid and sensitive detection of NGAL for the prediction of acute kidney injury via a polydopamine nanosphere/aptamer nanocomplex coupled with DNase I-assisted recycling amplification
    Hu, Yiting
    Yu, Xie-An
    Zhang, Ying
    Zhang, Ran
    Bai, Xuefei
    Lu, Mi
    Li, Jiwei
    Gu, Lifei
    Liu, Ji-Hua
    Yu, Bo-Yang
    Tian, Jiangwei
    ANALYST, 2020, 145 (10) : 3620 - 3625
  • [32] Dual-target electrochemical DNA sensor for detection of Pb2+ and Hg2+ simultaneously by exonuclease I-assisted recycling signal amplification
    Wang, Yue
    Zhai, Hongguo
    Yin, Jiaqi
    Guo, Qi
    Zhang, Yuhao
    Yang, Qingqing
    Li, Falan
    Sun, Xia
    Guo, Yemin
    Zhang, Yanyan
    MICROCHIMICA ACTA, 2022, 189 (12)
  • [33] A fluorescent aptasensor based on nitrogen-doped carbon supported palladium and exonuclease III-assisted signal amplification for sensitive detection of AFB1
    Zhao, Luyang
    Suo, Zhiguang
    He, Baoshan
    Huang, Yawei
    Liu, Yong
    Wei, Min
    Jin, Huali
    Analytica Chimica Acta, 2022, 1226
  • [34] A fluorescent aptasensor based on nitrogen-doped carbon supported palladium and exonuclease III-assisted signal amplification for sensitive detection of AFB1
    Zhao, Luyang
    Suo, Zhiguang
    He, Baoshan
    Huang, Yawei
    Liu, Yong
    Wei, Min
    Jin, Huali
    ANALYTICA CHIMICA ACTA, 2022, 1226
  • [35] Sensitive fluorescent detection of exosomal microRNA based on enzymes-assisted dual-signal amplification
    Xia, Yaokun
    Huang, Zening
    Chen, Tingting
    Xu, Lilan
    Zhu, Gengzhen
    Chen, Wenqian
    Chen, Guanyu
    Wu, Shuxiang
    Lan, Jianming
    Lin, Xu
    Chen, Jinghua
    BIOSENSORS & BIOELECTRONICS, 2022, 209
  • [36] Homogeneous electrochemical aptamer-based ATP assay with signal amplification by exonuclease III assisted target recycling
    Liu, Shufeng
    Wang, Ying
    Zhang, Chengxin
    Lin, Ying
    Li, Feng
    CHEMICAL COMMUNICATIONS, 2013, 49 (23) : 2335 - 2337
  • [37] Exonuclease III-assisted multiple cycle amplification for the sensitive detection of DNA with zero background signal
    Liu, Wen-Jing
    Xu, Qinfeng
    Ma, Fei
    Li, Chen-Chen
    Zhang, Chun-Yang
    ANALYST, 2018, 143 (22) : 5461 - 5466
  • [38] Polydopamine Nanotubes as an Effective Fluorescent Quencher for Highly Sensitive and Selective Detection of Biomolecules Assisted with Exonuclease III Amplification
    Fan, Daoqing
    Zhu, Xiaoqing
    Zhai, Qingfeng
    Wang, Erkang
    Dong, Shaojun
    ANALYTICAL CHEMISTRY, 2016, 88 (18) : 9158 - 9165
  • [39] Sensitive and Label-Free Fluorescent Detection of Transcription Factors Based on DNA-Ag Nanoclusters Molecular Beacons and Exonuclease III-Assisted Signal Amplification
    Li, Bingzhi
    Xu, Lei
    Chen, Yue
    Zhu, Wanying
    Shen, Xin
    Zhu, Chunhong
    Luo, Jieping
    Li, Xiaoxu
    Hong, Junli
    Zhou, Xuemin
    ANALYTICAL CHEMISTRY, 2017, 89 (14) : 7316 - 7323
  • [40] Aptamer-Based Fluorescent Assay for Sensitive Detection of Cardiac Troponin I
    Li Y.
    Yang Y.
    Lü X.
    Deng Y.
    Lü, Xuefei (xuefeilv@163.com), 1600, Beijing Institute of Technology (29): : 45 - 51