Human-in-the-loop optimization of wearable device parameters using an EMG-based objective function

被引:0
|
作者
Diaz, Maria Alejandra [1 ,2 ]
De Bock, Sander [2 ]
Beckerle, Philipp [3 ,4 ]
Babic, Jan [5 ,6 ]
Verstraten, Tom [1 ,7 ,8 ]
De Pauw, Kevin [1 ,2 ]
机构
[1] Vrije Univ Brussel, BruBot, B-1050 Brussels, Belgium
[2] Vrije Univ Brussel, Human Physiol & Sports Physiotherapy Res Grp, B-1050 Brussels, Belgium
[3] Friedrich Alexander Univ Erlangen Nurnberg, Inst Autonomous Syst & Mechatron, Dept Elect Engn, D-91052 Erlangen, Germany
[4] Friedrich Alexander Univ Erlangen Nurnberg, Dept Artificial Intelligence Biomed Engn, D-91052 Erlangen, Germany
[5] Jozef Stefan Inst, Dept Automat Biocybernet & Robot, Lab Neuromech & Biorobot, Ljubljana 1000, Slovenia
[6] Univ Ljubljana, Fac Elect Engn, Ljubljana 1000, Slovenia
[7] Vrije Univ Brussel, Robot & Multibody Mech Res Grp, B-1050 Brussels, Belgium
[8] Flanders Make, B-1050 Brussels, Belgium
来源
WEARABLE TECHNOLOGIES | 2024年 / 5卷
关键词
human-robot interaction; optimization; performance augmentation; human-in-the-loop optimization; MUSCLE SYNERGIES; COST; RECRUITMENT;
D O I
10.1017/wtc.2024.9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Advancements in wearable robots aim to improve user motion, motor control, and overall experience by minimizing energetic cost (EC). However, EC is challenging to measure and it is typically indirectly estimated through respiratory gas analysis. This study introduces a novel EMG-based objective function that captures individuals' natural energetic expenditure during walking. The objective function combines information from electromyography (EMG) variables such as intensity and muscle synergies. First, we demonstrate the similarity of the proposed objective function, calculated offline, to the EC during walking. Second, we minimize and validate the EMG-based objective function using an online Bayesian optimization algorithm. The walking step frequency is chosen as the parameter to optimize in both offline and online approaches in order to simplify experiments and facilitate comparisons with related research. Compared to existing studies that use EC as the objective function, results demonstrated that the optimization of the presented objective function reduced the number of iterations and, when compared with gradient descent optimization strategies, also reduced convergence time. Moreover, the algorithm effectively converges toward an optimal step frequency near the user's preferred frequency, positively influencing EC reduction. The good correlation between the estimated objective function and measured EC highlights its consistency and reliability. Thus, the proposed objective function could potentially optimize lower limb exoskeleton assistance and improve user performance and human-robot interaction without the need for challenging respiratory gas measurements.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Human Factors in the Age of Algorithms. Understanding the Human-in-the-loop Using Agent-Based Modeling
    Valdez, Andre Calero
    Ziefle, Martina
    SOCIAL COMPUTING AND SOCIAL MEDIA: TECHNOLOGIES AND ANALYTICS, SCSM 2018, PT II, 2018, 10914 : 357 - 371
  • [42] MULTI OBJECTIVE OPTIMIZATION OF FLUX CORED ARC WELD PARAMETERS USING FUZZY BASED DESIRABILITY FUNCTION
    Satheesh, M.
    Dhas, J. Edwin Raja
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2013, 37 (M2) : 175 - 187
  • [43] Surge Margin Optimization of Centrifugal Compressors Using a New Objective Function Based on Local Flow Parameters
    Ratz, Johannes
    Leichtfuss, Sebastian
    Beck, Maximilian
    Schiffer, Heinz-Peter
    Froehlig, Friedrich
    INTERNATIONAL JOURNAL OF TURBOMACHINERY PROPULSION AND POWER, 2019, 4 (04)
  • [44] Online Replanning With Human-in-the-Loop for Non-Prehensile Manipulation in Clutter - A Trajectory Optimization Based Approach
    Papallas, Rafael
    Cohn, Anthony G.
    Dogar, Mehmet R.
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2020, 5 (04) : 5377 - 5384
  • [45] Embodiment of a virtual prosthesis through training using an EMG-based human-machine interface: Case series
    Rodrigues, Karina Aparecida
    Moreira, Joao Vitor da Silva
    Pinheiro, Daniel Jose Lins Leal
    Dantas, Rodrigo Lantyer Marques
    Santos, Thais Cardoso
    Nepomuceno, Joao Luiz Vieira
    Nogueira, Maria Angelica Ratier Jajah
    Cavalheiro, Esper Abrao
    Faber, Jean
    FRONTIERS IN HUMAN NEUROSCIENCE, 2022, 16
  • [46] A Hybrid Motion Classification Approach for EMG-Based Human-Robot Interfaces Using Bayesian and Neural Networks
    Bu, Nan
    Okamoto, Masaru
    Tsuji, Toshio
    IEEE TRANSACTIONS ON ROBOTICS, 2009, 25 (03) : 502 - 511
  • [47] HUMAN-IN-THE-LOOP AGENT-BASED SIMULATION FOR IMPROVED AUTONOMOUS SURVEILLANCE USING UNMANNED VEHICLES
    Minaeian, Sara
    Yuan, Yifei
    Liu, Jian
    Son, Young-Jun
    2015 WINTER SIMULATION CONFERENCE (WSC), 2015, : 3126 - 3127
  • [48] A time-scale based objective function for EEG signal parameters optimization
    Bouchema, Asma
    Kacha, Abdellah
    Nonclercq, Antoine
    Grenez, Francis
    2015 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2015, : 348 - +
  • [49] Optimization of deep neural network-based human activity recognition for a wearable device
    Suwannarat, K.
    Kurdthongmee, W.
    HELIYON, 2021, 7 (08)
  • [50] Using agent-based modeling and human-in-the-loop simulation to analyze army acquisition programs
    Downes, PM
    Kwinn, MJ
    Brown, DE
    PROCEEDINGS OF THE 2004 WINTER SIMULATION CONFERENCE, VOLS 1 AND 2, 2004, : 994 - 1000