Accuracy of Continuous Glucose Monitoring in People With Type 1 Diabetes Receiving Hemodialysis in Hospital

被引:0
|
作者
Wang, Ray [1 ,2 ,3 ,4 ,5 ]
Kyi, Mervyn [1 ,2 ,3 ]
Krishnamoorthi, Brintha [5 ]
Connell, Ailie [4 ,6 ]
Chiang, Cherie [1 ,2 ,7 ]
Renouf, Debra [5 ]
Barmanray, Rahul [1 ,2 ,3 ]
Dwyer, Karen [8 ]
Fourlanos, Spiros [1 ,2 ,3 ]
机构
[1] Royal Melbourne Hosp, Dept Diabet & Endocrinol, Level 4 West,300 Grattan St, Parkville, Vic 3050, Australia
[2] Univ Melbourne, Royal Melbourne Hosp, Dept Med, Parkville, Vic, Australia
[3] Univ Melbourne, Australian Ctr Accelerating Diabet Innovat, Parkville, Vic, Australia
[4] Eastern Hlth, Dept Endocrinol & Diabet, Box Hill, Vic, Australia
[5] Peninsula Hlth, Dept Diabet & Endocrinol, Frankston, Vic, Australia
[6] Eastern Hlth, Dept Chem Pathol, Box Hill, Vic, Australia
[7] Royal Melbourne Hosp, Dept Pathol, Parkville, Vic, Australia
[8] Royal Melbourne Hosp, Dept Nephrol, Parkville, Vic, Australia
关键词
accuracy; CGM; hemodialysis; hospitalization; inpatient; type; 1; diabetes;
D O I
10.1177/19322968251318758
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Accuracy of Continuous Glucose Monitoring in Hemodialysis Patients With Diabetes
    Narasaki, Yoko
    Kalantar-Zadeh, Kamyar
    Daza, Andrea C.
    You, Amy S.
    Novoa, Alejandra
    Peralta, Renal Amel
    Siu, Man Kit Michael
    Nguyen, Danh V.
    Rhee, Connie M.
    DIABETES CARE, 2024, 47 (11)
  • [2] Putting Continuous Glucose Monitoring to Work for People With Type 1 Diabetes
    Hood, Korey K.
    DiMeglio, Linda A.
    Riddle, Matthew C.
    DIABETES CARE, 2020, 43 (01) : 19 - 21
  • [3] COST EFFECTIVENESS OF CONTINUOUS GLUCOSE MONITORING IN PEOPLE WITH TYPE 1 DIABETES
    Ljaljic, A.
    Yoels, B.
    Villa, Zapata L.
    VALUE IN HEALTH, 2023, 26 (06) : S101 - S101
  • [4] Continuous glucose monitoring in patients with type 2 diabetes on hemodialysis
    Maurizio Gallieni
    Cristina De Salvo
    Maria Elena Lunati
    Antonio Rossi
    Francesca D’Addio
    Ida Pastore
    Gianmarco Sabiu
    Roberta Miglio
    Gian Vincenzo Zuccotti
    Paolo Fiorina
    Acta Diabetologica, 2021, 58 : 975 - 981
  • [5] Continuous glucose monitoring in patients with type 2 diabetes on hemodialysis
    Gallieni, Maurizio
    De Salvo, Cristina
    Lunati, Maria Elena
    Rossi, Antonio
    D'Addio, Francesca
    Pastore, Ida
    Sabiu, Gianmarco
    Miglio, Roberta
    Zuccotti, Gian Vincenzo
    Fiorina, Paolo
    ACTA DIABETOLOGICA, 2021, 58 (08) : 975 - 981
  • [6] Comparison of accuracy between flash glucose monitoring and continuous glucose monitoring in patients with type 2 diabetes mellitus undergoing hemodialysis
    Matoba, Kenta
    Hayashi, Akinori
    Shimizu, Naoya
    Moriguchi, Ibuki
    Kobayashi, Naoyuki
    Shichiri, Masayoshi
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2020, 34 (11)
  • [7] Comparison of Glucose Metrics by Capillary Blood Glucose and Continuous Glucose Monitoring among People with Type 2 Diabetes on Hemodialysis
    Galindo, Rodolfo J.
    Gerges, Amany Y. G.
    Moazzami, Bobak
    Peng, Limin
    Tuttle, Katherine R.
    Umpierrez, Guillermo
    DIABETES, 2023, 72
  • [8] Accuracy of Continuous Glucose Monitoring During Exercise in Type 1 Diabetes Pregnancy
    Kumareswaran, Kavita
    Elleri, Daniela
    Allen, Janet M.
    Caldwell, Karen
    Nodale, Marianna
    Wilinska, Malgorzata E.
    Amiel, Stephanie A.
    Hovorka, Roman
    Murphy, Helen R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (03) : 223 - 229
  • [9] The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1
    Vokounova-Honsova, Sarka
    Navratil, Tomas
    Kohlikova, Eva
    MONATSHEFTE FUR CHEMIE, 2018, 149 (09): : 1659 - 1669
  • [10] Effect of Lipohypertrophy on Accuracy of Continuous Glucose Monitoring in Patients With Type 1 Diabetes
    DeSalvo, Daniel J.
    Maahs, David M.
    Messer, Laurel
    Wadwa, R. Paul
    Payne, Shelby
    Ly, Trang T.
    Buckingham, Bruce A.
    DIABETES CARE, 2015, 38 (10) : E166 - E167