The New Alternative Technique Outcomes: Atlas Lateral Mass Screw and C2-3 Transfacet Screw Fixation for Complex Atlantoaxial Instability in Patients with Thin C2 Pedicle or High-Riding Vertebral Artery

被引:0
|
作者
Cine, Hidayet Safak [1 ]
Avci, Idris [2 ]
Uysal, Ece [3 ]
Unsal, Ulkun Unlu [4 ]
Gunaydin, Mehmet Emre [3 ]
Paksoy, Kemal [5 ]
Senturk, Salim [5 ]
Yaman, Onur [5 ]
机构
[1] Istanbul Medeniyet Univ, Prof Dr Suleyman Yalcin City Hosp, Dept Neurosurg, Istanbul, Turkiye
[2] Uskudar Univ, Dept Neurosurg, Istanbul, Turkiye
[3] Univ Hlth Sci, Prof Dr Cemil Tascioglu City Hosp, Dept Neurosurg, Istanbul, Turkiye
[4] Manisa City Hosp, Dept Neurosurg, Manisa, Turkiye
[5] Mem Bahcelievler Hosp, Spine Ctr, Dept Neurosurg, Istanbul, Turkiye
关键词
Alternative technique; Atlantoaxial instability; C1 lateral mass screw; C2-3 transfacet screw; Odontoid fracture; CERVICAL-SPINE; C1-C2; KINEMATICS; SURGERY; FUSION;
D O I
10.1016/j.wneu.2024.08.100
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: The study aimed to evaluate the safety, feasibility, effect on fusion, and clinical efficacy of atlas lateral mass and C2-3 transfacet screw fixation technique, serves as an alternative method to traditional posterior atlantoaxial fixation. METHODS: Patients with atlantoaxial instability who underwent atlas lateral mass and C2-3 transfacet fixation surgery were included. The duration of the surgery and the quantity of blood lost during the operation were recorded. Patients were monitored via X-ray and computed tomography scans to evaluate the degree of fusion at the 1-month and 12-month follow-up. The Neck Visual Analog Scale and Neck Disability Index were evaluated preoperatively, in the postoperative first week, and at the 12-month follow-up for clinical follow-up. RESULTS: A total of 8 patients with atlantoaxial instability due to odontoid fracture or Arnold- Chiari malformation accompanied by bony or vascular abnormalities were included in the study between 2017 and 2024. All 8 patients underwent successful atlas lateral mass and C2-3 transfacet screw fixation, with no neurovascular injury noted during surgery. All patients with fracture exhibited fusion at the 12-month mark, and both the Neck Visual Analog Scale and Neck Disability Index scores demonstrated significant improvement at both the 1-week and 12-month postoperative periods (P< 0.05). CONCLUSIONS: The atlas lateral mass and C2-3 trans- facet screw fixation technique, an alternative to conventional posterior fixation, has been demonstrated to be an efficacious method for providing adequate stabilization and fusion in patients with atlantoaxial instability, even in the cases of thin C2 pedicle, high-riding vertebral artery, previous failed surgeries, or reoperation.
引用
收藏
页码:E246 / E255
页数:10
相关论文
共 50 条
  • [41] C2 laminar screw and C1-2 transarticular screw combined with C1 laminar hooks for atlantoaxial instability with unilateral vertebral artery injury
    Guo, Qunfeng
    Liu, Jun
    Ni, Bin
    Lu, Xuhua
    Zhou, Fengjin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) : 1207 - 1210
  • [42] Radiographic Evaluation of the Technique for C1 Lateral Mass and C2 Pedicle Screw Fixation in Three Hundred Nineteen Cases
    Wang, Shenglin
    Wang, Chao
    Wood, Kirkham B.
    Yan, Ming
    Zhou, Haitao
    SPINE, 2011, 36 (01) : 3 - 8
  • [43] Safety Issues and Neurological Improvement following C1-C2 Fusion using C1 Lateral Mass and C2 Pedicle Screw in Atlantoaxial Instability
    Kwan, M. K.
    Chan, C. Y. W.
    Kwan, T. C. C.
    Gashi, Y. N.
    Saw, L. B.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2010, 4 (02) : 17 - 22
  • [44] Biomechanical evaluation of two alternative techniques to the Goel-Harms technique for atlantoaxial fixation: C1 lateral mass-C2 bicortical translaminar screw fixation and C1 lateral mass-C2/3 transarticular screw fixation
    Du, Yue-Qi
    Li, Teng
    Ma, Chao
    Qiao, Guang-Yu
    Yin, Yi-Heng
    Yu, Xin-Guang
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 32 (05) : 682 - 688
  • [45] C2 medial pedicle screw: a novel "in-out-in" technique as an alternative option for posterior C2 fixation in cases with a narrow C2 isthmus
    Du, Yue-Qi
    Yin, Yi-Heng
    Qiao, Guang-Yu
    Yu, Xin-Guang
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 33 (03) : 281 - 287
  • [46] Feasibility of C2 Pedicle Screw Fixation With the "in-out-in" Technique for Patients With Basilar Invagination
    Xu, Panjie
    Lin, Junyu
    Xiao, Hang
    Zheng, Jianying
    Ji, Wei
    SPINE, 2024, 49 (11) : 798 - 804
  • [47] Clinical outcome of posterior fixation of the C1 lateral mass and C2 pedicle by polyaxial screw and rod
    Jeon, Sei Woong
    Jeong, Je Noon
    Choi, Gi Hoon
    Moon, Seung Myung
    Hwang, Hyung Sik
    Choi, Sun Kil
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2012, 114 (06) : 539 - 544
  • [48] Pedicle Screw Combined With Lateral Mass Screw Fixation in the Treatment of Basilar Invagination and Congenital C2-C3 Fusion
    Wang, Shenglin
    Wang, Chao
    Leng, Huijie
    Zhao, Weidong
    Yan, Ming
    Zhou, Haitao
    CLINICAL SPINE SURGERY, 2016, 29 (10): : 448 - 453
  • [49] Types of high-riding vertebral artery: a classification system for preoperative planning of C2 instrumentation based on 908 potential screw insertion sites
    Klepinowski, Tomasz
    Zylka, Natalia
    Pettersson, Samuel D.
    Hanaya, Jagoda
    Pala, Bartlomiej
    Latka, Kajetan
    Taterra, Dominik
    Poncyljusz, Wojciech
    Ogilvy, Christopher S.
    Sagan, Leszek
    SPINE JOURNAL, 2025, 25 (01): : 59 - 68
  • [50] Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for C1 Lateral Mass and C2 Pedicle Screw Placement for Atlantoaxial Instability
    Yang, Yong Liang
    Zhou, Dong Sheng
    He, Ji Liang
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (03): : 127 - 134