Magnetic Resonance Acoustic Radiation Force Imaging (MR-ARFI)

被引:0
|
作者
Odeen, Henrik [1 ,2 ]
Payne, Allison H. [2 ]
Parker, Dennis L. [2 ]
机构
[1] Utah Ctr Adv Imaging Res, 729 Arapeen Dr, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT USA
关键词
acoustic radiation force imaging; ARFI; MR-ARFI; focused ultrasound; high intensity focused ultrasound; thermal therapy; FOCUSED ULTRASOUND NEUROMODULATION; IMPULSE DIFFRACTION FIELD; IN-VIVO; TISSUE DISPLACEMENT; THERMOMETRY; TEMPERATURE; ELASTOGRAPHY; FEASIBILITY; CONTRAST; ABLATION;
D O I
10.1002/jmri.29712
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This review covers the theoretical background, pulse sequence considerations, practical implementations, and multitudes of applications of magnetic resonance acoustic radiation force imaging (MR-ARFI) described to date. MR-ARFI is an approach to encode tissue displacement caused by the acoustic radiation force of a focused ultrasound field into the phase of a MR image. The displacement encoding is done with motion encoding gradients (MEG) which have traditionally been added to spin echo-type and gradient recalled echo-type pulse sequences. Many different types of MEG (monopolar, bipolar, tripolar etc.) have been described and pros and cons are discussed. We further review studies investigating the safety of MR-ARFI, as well as approaches to simulate the MR-ARFI displacement. Lastly, MR-ARFI applications such as for focal spot localization, tissue stiffness interrogation following thermal ablation, trans-skull aberration correction, and simultaneous MR-ARFI and MR thermometry are discussed.Evidence LevelN/ATechnical EfficacyStage 1
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Rapid HIFU autofocusing using the entire MR-ARFI image
    Grissom, William A.
    Kaye, Elena
    Pauly, Kim Butts
    Zur, Yuval
    Yeo, Desmond
    Medan, Yoav
    Davis, Cynthia
    12TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2012, 1503 : 162 - 167
  • [22] Evaluation of Neonatal Brain Development Using Acoustic Radiation Force Impulse Imaging (ARFI)
    Su, Y.
    Ma, J.
    Du, L. F.
    Xia, J.
    Wu, Y.
    Jia, X.
    Cai, Y. G.
    Li, Y. H.
    Zhao, J.
    Liu, Q.
    NEUROPHYSIOLOGY, 2015, 47 (04) : 322 - 325
  • [23] Noninvasive Assessment of Liver Fibrosis Using Acoustic Radiation Force Impulse (ARFI) Imaging
    Bajwa, A.
    Wood, C.
    Berggruen, S.
    Miller, F.
    Ganger, D.
    Grant, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [24] Evaluation of Neonatal Brain Development Using Acoustic Radiation Force Impulse Imaging (ARFI)
    Y. Su
    J. Ma
    L. F. Du
    J. Xia
    Y. Wu
    X. Jia
    Y. G. Cai
    Y. H. Li
    J. Zhao
    Q. Liu
    Neurophysiology, 2015, 47 : 322 - 325
  • [25] In vivo demonstration of Acoustic Radiation Force Impulse (ARFI) imaging in the thyroid, abdomen, and breast
    Nightingale, K
    Soo, MS
    Nightingale, R
    Bentley, R
    Trahey, G
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 1633 - 1638
  • [26] Dual-frequency IVUS transducer for acoustic radiation force impulse (ARFI) imaging
    Wang, Zhuochen
    Jiang, Xiaoning
    Czernuszewicz, Tomasz J.
    Gallippi, Caterina M.
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [27] PRELIMINARY RESULTS OF ACOUSTIC RADIATION FORCE IMPULSE (ARFI) ULTRASOUND IMAGING OF BREAST LESIONS
    Meng, Wei
    Zhang, Guangchen
    Wu, Changjun
    Wu, Guozhu
    Song, Yan
    Lu, Zhaoling
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (09): : 1436 - 1443
  • [28] Acoustic Radiation Force Impulse (ARFI) ultrasound imaging of solid focal liver lesions
    Gallotti, A.
    D'Onofrio, M.
    Romanini, L.
    Cantisani, V.
    Mucelli, R. Pozzi
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : 451 - 455
  • [29] Variable ultrasound trigger delay for improved magnetic resonance acoustic radiation force imaging
    Mougenot, Charles
    Waspe, Adam
    Looi, Thomas
    Drake, James M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02): : 712 - 727
  • [30] Magnetic resonance elastography (MRE) outperforms acoustic force radiation impulse (ARFI) in predicting oesophageal varices in obese NAFLD cirrhosis
    Roy, Akash
    Verma, Nipun
    Jajodia, Surabhi
    Goenka, Usha
    Tiwari, Awanish
    Sonthalia, Nikhil
    Goenka, Mahesh
    ABDOMINAL RADIOLOGY, 2024, 49 (09) : 3088 - 3095