An Optimized Liquid Chromatography-Mass Spectrometry Method for Ganglioside Analysis in Cell Lines

被引:0
|
作者
Sanni, Akeem [1 ]
Bennett, Andrew I. [1 ]
Huang, Yifan [1 ]
Gidi, Isabella [1 ]
Adeniyi, Moyinoluwa [1 ]
Nwaiwu, Judith [1 ]
Kang, Min H. [2 ]
Keyel, Michelle E. [2 ]
Gao, ChongFeng [3 ]
Reynolds, C. Patrick [2 ]
Haab, Brian [3 ]
Mechref, Yehia [1 ]
机构
[1] Texas Tech Univ, Chem & Biochem Dept, Lubbock, TX 79409 USA
[2] Texas Tech Univ Hlth Sci Ctr TTUHSC, Canc Ctr, Sch Med, Lubbock, TX 79416 USA
[3] Van Andel Inst, Grand Rapids, MI 49503 USA
基金
美国国家卫生研究院;
关键词
gangliosides; ZIC-HILIC; LC-MS; neuroblastoma; HUNTINGTONS-DISEASE; CEREBROSPINAL-FLUID; GD2; EXPRESSION; BRAIN; GM1; METABOLISM; SEPARATION;
D O I
10.3390/cells13191640
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Gangliosides are glycosphingolipids composed of a sialylated glycan head group and a ceramide backbone. These anionic lipids form lipid rafts and play crucial roles in regulating various proteins involved in signal transduction, adhesion, and cell-cell recognition. Neuroblastoma, a pediatric cancer of the sympathetic nervous system, is treated with intensive chemotherapy, radiation, and an antibody targeting the GD2 ganglioside. Gangliosides are critical in neuroblastoma development and serve as therapeutic targets, making it essential to establish a reliable, rapid, and cost-effective method for profiling gangliosides, particularly one capable of isomeric separation of intact species. In this study, liquid chromatography-mass spectrometry (LC-MS) was optimized using standard gangliosides, followed by the optimization of sphingolipid extraction methods from cell lines by comparing Folch and absolute methanol extraction techniques. Percent recovery and the number of identified sphingolipids were used to evaluate the analytical merits of these methods. A standard gangliosides calibration curve demonstrated excellent linearity (R2 = 0.9961-0.9975). The ZIC-HILIC column provided the best separation of ganglioside GD1 isomers with a 25 min runtime. GD1a elutes before GD1b on the ZIC-HILIC column. Absolute methanol yielded better percent recovery (96 +/- 7) and identified 121 different sphingolipids, the highest number between the two extraction methods. The optimized method was applied to profile gangliosides in neuroblastoma (COG-N-683), pancreatic cancer (PSN1), breast cancer (MDA-MB-231BR), and brain tumor (CRL-1620) cell lines. The ganglioside profile of the neuroblastoma cell line COG-N-683 showed an inverse relationship between GD1 and GD2. Ceramide, Hex1Cer, GM1, and GM3 were highly abundant in CRL-1620, PSN1, and MDA-MB-231BR, respectively. These results suggest that our method provides a sensitive, reliable, and high-throughput workflow for ganglioside profiling across different cell types.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] An optimized electrochemistry-liquid chromatography-mass spectrometry method for studying guanosine oxidation
    Erb, Robert
    Plattner, Sabine
    Pitterl, Florian
    Brouwer, Hendrik-Jan
    Oberacher, Herbert
    ELECTROPHORESIS, 2012, 33 (04) : 614 - 621
  • [2] Analysis of fungicides by liquid chromatography-mass spectrometry
    Raina-Fulton, Renata
    Mohamad, Aisha
    Behdarvandan, Asal
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [3] Liquid chromatography-mass spectrometry analysis of propolis
    Midorikawa, K
    Banskota, AH
    Tezuka, Y
    Nagaoka, T
    Matsushige, K
    Message, D
    Huertas, AAG
    Kadota, S
    PHYTOCHEMICAL ANALYSIS, 2001, 12 (06) : 366 - 373
  • [4] LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
    VESTAL, ML
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 181 (MAR): : 79 - ANYL
  • [5] Analysis of milk with liquid chromatography-mass spectrometry: a review
    Imperiale, Sebastian
    Morozova, Ksenia
    Ferrentino, Giovanna
    Scampicchio, Matteo
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2023, 249 (04) : 861 - 902
  • [6] Analysis of Trichothecenes Using Liquid Chromatography-Mass Spectrometry
    James, Kevin J.
    Frahill, James
    Furey, Ambrose
    FOOD CONTAMINANTS: MYCOTOXINS AND FOOD ALLERGENS, 2008, 1001 : 211 - 240
  • [7] Nanoscale liquid chromatography-mass spectrometry for proteomic analysis
    Neyer, DW
    Hahnenberger, KM
    Bailey, CG
    AMERICAN LABORATORY, 2003, 35 (24) : 11 - +
  • [8] Classification of natural resins by liquid chromatography-mass spectrometry and gas chromatography-mass spectrometry using chemometric analysis
    Rhourrhi-Frih, B.
    West, C.
    Pasquier, L.
    Andre, P.
    Chaimbault, P.
    Lafosse, M.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1256 : 177 - 190
  • [9] Applications of liquid chromatography-mass spectrometry for food analysis
    Di Stefano, Vita
    Avellone, Giuseppe
    Bongiorno, David
    Cunsolo, Vincenzo
    Muccilli, Vera
    Sforza, Stefano
    Dossena, Arnaldo
    Drahos, Laszlo
    Vekey, Karoly
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1259 : 74 - 85
  • [10] Protein glycosylation analysis by liquid chromatography-mass spectrometry
    Wuhrer, M
    Deelder, AM
    Hokke, CH
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 825 (02): : 124 - 133