Quartz Crystal Microbalance Sensor Based onZnO-Graphene Thin Film for Gas Detection

被引:0
|
作者
Boutamine, M. [1 ]
Bakha, Y.
Saidani, H. [2 ]
Hachemi, H. [1 ]
Guerfi, A. D. [1 ]
Sebbah, C. [1 ]
Aberkane, S. [1 ]
Khales, H.
Bellel, A. [3 ]
机构
[1] Cherchell Acad DPHB, Res Lab Elect & Elect Syst Engn, Sci & Technol Res Directorate, Cherchell, Algeria
[2] Univ Bristol, Dept Mech Engn, EEME Sch, Queens Bldg,Univ Walk, Bristol BS8 1TR, England
[3] Univ Constantine 1, Fac Sci & Technol, Lab Elect Mat Med Applicat, Constantine, Algeria
关键词
topics; spray pyrolysis deposition; zinc oxide and graphene; gas sensor; quartz crystal microbalance(QCM); ZNO; COMPOSITE;
D O I
10.12693/APhysPolA.145.265
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Gas detection is vital for safety in important industrial and private sectors. Its major significance lies inits proactive risk mitigation, safeguarding lives and resources. In this paper, the focus is on the devel-opment of a gas sensor based on quartz crystal microbalance coated with a sensitive layer of zinc oxide(ZnO)-graphene nanocomposite for the detection of volatile organic compounds at room temperature.The incorporation of graphene or reduced graphene oxide is preferred in such applications due to theirexcellent electrical conductivity, chemical stability, and high surface area. These nanocomposites weresynthesized using a chemical method via spray pyrolysis. Various techniques were employed to analyzethe coated QCM electrode: contact angle measurements to assess surface wettability, Fourier transforminfrared and energy-dispersive X-ray spectroscopy to investigate the composition of the coated elec-trode, and scanning electron and atomic force microscopies were used to study its surface morphology.These analyses provided valuable insights into the nanocomposite's interaction with the environment,composition, structure, and topography of the sensor's sensitive layer. To evaluate the sensor's sensitiv-ity, the frequency shift (triangle f) of the coated QCM electrode is monitored when exposed to different gasconcentrations of ethanol, toluene, chloroform, humidity, and formamide, ranging from 47 to 142 ppm.The frequency shift indicated the detected gas concentration. The results demonstrate good repeata-bility and reversibility, which are crucial indicators of a sensor's reliability. This reliability is essen-tial for applications in environmental monitoring or industrial safety, where accurate gas detection iscritical.
引用
收藏
页数:74
相关论文
共 50 条
  • [11] Nanoporous Graphene Oxide-Based Quartz Crystal Microbalance Gas Sensor with Dual-Signal Responses for Trimethylamine Detection
    Qi, Guangyu
    Qu, Fangfang
    Zhang, Lu
    Chen, Shihao
    Bai, Mengyuan
    Hu, Mengjiao
    Lv, Xinyan
    Zhang, Jinglei
    Wang, Zhenhe
    Chen, Wei
    SENSORS, 2022, 22 (24)
  • [12] Quartz crystal microbalance dewpoint sensor for natural gas
    Shapiro, AP
    Dean, AJ
    INTERNAL STANDARDIZATION AND CALIBRATION ARCHITECTURES FOR CHEMICAL SENSORS, 1999, 3856 : 148 - 159
  • [13] Quartz Crystal Microbalance Sensor Based on ZnO Nanofilm for Methanol Detection
    Zhou, Yiwen
    Xu, Kaichun
    Zheng, Zichen
    He, Xiaoxi
    Zhang, Chao
    IEEE SENSORS JOURNAL, 2024, 24 (01) : 204 - 214
  • [14] Quartz crystal microbalance based histidine sensor
    Sonmezler, Merve
    Ozgur, Erdogan
    Yavuz, Handan
    Denizli, Adil
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2019, 47 (01) : 221 - 227
  • [15] Quartz Crystal Microbalance Coated with Vanadium Oxide Thin Film for CO2 Gas Sensor at Room Temperature
    Berouaken, Malika
    Talbi, Lamia
    Alkama, Rezak
    Sam, Sabrina
    Menari, Hamid
    Chebout, Katia
    Manseri, Amar
    Boucheham, Abdelghani
    Gabouze, Noureddine
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2018, 43 (11) : 5957 - 5963
  • [16] QUARTZ CRYSTAL MICROBALANCE USED AS SENSOR FOR PESTICIDES DETECTION
    Dulama, Ioana Daniela
    Radulescu, Cristiana
    Bucurica, Ioan Alin
    Teodorescu, Sofia
    Stirbescu, Raluca Maria
    Cimpoca, Gheorghe Valerica
    Let, Dorin Dacian
    Gurgu, Ion Valentin
    JOURNAL OF SCIENCE AND ARTS, 2018, (02): : 445 - 452
  • [17] Volatile organic compounds gas sensor based on quartz crystal microbalance for fruit freshness detection: A review
    Liu, Kewei
    Zhang, Chao
    FOOD CHEMISTRY, 2021, 334
  • [18] Polyaniline-Modified Quartz Crystal Microbalance Sensor for Detection of Formic Acid Gas
    Yan, Ying
    Lu, Dandan
    Zhou, Hao
    Hou, Haiping
    Zhang, Ting
    Wu, Laiming
    Cai, Lankun
    WATER AIR AND SOIL POLLUTION, 2012, 223 (03): : 1275 - 1280
  • [19] Chitosan Coating on Quartz Crystal Microbalance Gas Sensor for Isopropyl Alcohol and Acetone Detection
    Hekiem, Nurul Liyana Lukman
    Ralib, Aliza Aini Md
    Akmal, M. H. Maziati
    Ahmad, Farah B.
    Ab Rahim, Rosminazuin
    Za'bah, Nor Farahidah
    Sugandi, Gandi
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2022, 14 (03): : 241 - 249
  • [20] Polyaniline-Modified Quartz Crystal Microbalance Sensor for Detection of Formic Acid Gas
    Ying Yan
    Dandan Lu
    Hao Zhou
    Haiping Hou
    Ting Zhang
    Laiming Wu
    Lankun Cai
    Water, Air, & Soil Pollution, 2012, 223 : 1275 - 1280