Multi-objective optimization and performance evaluation of a cooling tower assisted ground source heat pump system under different intermittent control strategies

被引:0
|
作者
Liu, Yifei [1 ,2 ]
Zhang, Guozhu [1 ,2 ]
Wang, Zhongtao [3 ]
Ding, Jiayuan [4 ]
Wang, Hao [3 ]
Cao, Ziming [1 ,2 ]
机构
[1] Southeast Univ, Inst Geotech Engn, Nanjing 211189, Peoples R China
[2] Southeast Univ, Jiangsu Key Lab Low Carbon & Sustainable Geotech E, Nanjing 211189, Peoples R China
[3] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[4] Southeast Univ, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Nanjing 211189, Peoples R China
关键词
Multi-objective optimization; Performance evaluation; Ground source heat pump system; Cooling tower; Intermittent control strategies; THERMAL IMBALANCE; TAGUCHI METHOD; OPTIMAL-DESIGN; EXCHANGERS; ALGORITHM; MODEL;
D O I
10.1016/j.enbuild.2024.115268
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ground source heat pump (GHSP) system is widely utilized currently due to its advantages in economy, environment, and energy aspects. However, different building load demands during heating and cooling seasons cause the difference in heat intakes, leading to the ground thermal imbalance, and will further impact the operating performances of the system. Cooling tower (CT) is employed as an assisting method to alleviate the above problems in cooling-dominated areas. Various CT control strategies have been applied and studied nowadays, including fixed running time (FRT) control strategy, fixed entering fluid temperature (FET) control strategy, and fixed temperature difference (FTD) control strategy. In this study, multi-objective optimization (MOO) method is utilized and an optimizing framework is proposed based on NSGA-II. Concerning the economy, environment, and energy performances of cooling tower assisted ground source heat pump (CT-GSHP) system, operating period cost (OPC), operating period environmental performance (OPEP), and total energy consumption (TEC) are used as objective functions. COMSOL Multiphysics is utilized to establish the numerical model and demonstrate the performances of the system during a 10-year period. One representative set of optimized solutions illustrates that FET method has the best OPC with the value of 43.01 x 106 CNY, FTD method gets the best OPEP value of 2674.44 tCO2, and TEC of FRT is the lowest with the value of 2295.24 MWh. What's more, FRT, FET, and FTD methods keep the coefficient of performance (COP) and energy efficiency ratio (EER) at relatively stable ranges, and decrease the imbalance of ground temperature by 72.64 %, 75.03 %, and 76.98 %, respectively. Results of this research can offer references to the operation and enhance the comprehensive performances of CT-GSHP systems.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Model predictive control for a solar assisted ground source heat pump system
    Weeratunge, Hansani
    Narsilio, Guillermo
    de Hoog, Julian
    Dunstall, Simon
    Halgamuge, Saman
    ENERGY, 2018, 152 : 974 - 984
  • [42] Study on Operating and Control Strategies for Hybrid Ground Source Heat Pump System
    Zhang, Qing
    Lv, Nan
    Chen, Shengpeng
    Shi, Hao
    Chen, Zhenqian
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1894 - 1901
  • [43] Exergy Analysis of a Ground Source Heat Pump System Under Cooling and Heating Conditions
    Zhao, Lei
    Yuan, Chen
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 799 - 806
  • [44] Comprehensive performance evaluation method of working fluids for high temperature heat pump based on multi-objective optimization
    Xu, Chang
    Ma, Hongting
    Yu, Xiaohui
    APPLIED THERMAL ENGINEERING, 2024, 247
  • [45] Heating and cooling performance analysis of a ground source heat pump system in Southern Germany
    Luo, Jin
    Rohn, Joachim
    Bayer, Manfred
    Priess, Anna
    Wilkmann, Lucas
    Xiang, Wei
    GEOTHERMICS, 2015, 53 : 57 - 66
  • [46] Experimental investigation and performance analysis on ground source heat pump system for greenhouse cooling
    Chai, Lilong
    Ma, Chengwei
    Zhang, Xiaohui
    Qu, Mei
    Chen, Qingyun
    Yu, Fei
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2008, 24 (12): : 150 - 154
  • [47] Experimental investigation of the cooling performance of a ground source heat pump system in Denizli, Turkey
    Karabacak, Rasim
    Acar, Sengul Guven
    Kumsar, Halil
    Gokgoz, Ali
    Kaya, Mustafa
    Tulek, Yahya
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (02): : 454 - 465
  • [48] Study on intermittent operation strategies of a hybrid ground-source heat pump system with double-cooling towers for hotel buildings
    Yang, Jing
    Xu, Linghong
    Hu, Pingfang
    Zhu, Na
    Chen, Xuepeng
    ENERGY AND BUILDINGS, 2014, 76 : 506 - 512
  • [49] Life Cycle Cost Optimization of a Solar Assisted Ground Source Heat Pump System
    Weeratunge, Hansani
    de Hoog, Julian
    Dunstall, Simon
    Narsilio, Guillermo
    Halgamuge, Saman
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [50] Performance analysis and multi-objective optimization of a poly-generation system based on PEMFC, DCMD and heat pump
    Zhu, Wanchao
    Han, Jitian
    Ge, Yi
    Yang, Jinwen
    Liang, Wenxing
    DESALINATION, 2023, 555