Development and application of solid phase microextraction tips (SPME LC tips) method for therapeutic drug monitoring of gefitinib by LC-MS/MS

被引:0
|
作者
Rodrigues, Leonardo Costalonga [1 ,2 ]
Lima, Lilian de Araujo [1 ,2 ]
Berlinck, Debora Zorron [2 ,3 ]
Morau, Mariana Vieira [3 ]
Perroud Junior, Mauricio Wesley [1 ]
Moriel, Patricia [3 ]
Costa, Jose Luiz [2 ,3 ]
机构
[1] Univ Estadual Campinas UNICAMP, Fac Ciencias Med, BR-13083887 Campinas, SP, Brazil
[2] Univ Estadual Campinas UNICAMP, Ctr Informacao & Assistencia Toxicol Campinas CIAT, BR-13083881 Campinas, SP, Brazil
[3] Univ Estadual Campinas UNICAMP, Fac Ciencias Farmaceut, BR-13083871 Campinas, SP, Brazil
来源
基金
巴西圣保罗研究基金会;
关键词
Solid phase microextraction tips; Gefitinib; Plasma; Therapeutic drug monitoring; Green analytical toxicology; LC-MS/MS; LIQUID-CHROMATOGRAPHY; HUMAN PLASMA; CANCER; METABOLITES; VALIDATION; ERLOTINIB;
D O I
10.1016/j.greeac.2024.100177
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lung cancer can be divided into small cell lung cancer and non-small cell lung cancer (NSCLC). Among the existing therapies for NSCLC, epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKIs) can be mentioned. Gefitinib is one of the first-generation reversible EGFR-TKIs and its main metabolite is O-desmethylgefitinib. The therapeutic range upper limit for gefitinib has not yet been clearly established despite being an indication of its toxicity, and its adverse drug reaction may be unpredictable. Therefore, therapeutic drug monitoring (TDM) can be applied by measuring gefitinib concentration in blood and its fractions. Solid phase microextraction (SPME) is a miniaturized sample preparation technique, and SPME LC tips represent a variation of SPME. This technique utilizes an inert support coated with HPLC-type silica particles, presenting several advantages. Here, we successfully developed, optimized, and validated a green analytical method for the quantification of gefitinib and its metabolite, O-desmethylgefitinib, in plasma samples, by SPME LC tips and LCMS/MS. Linearity was achieved from 20 to 800 ng/mL and LLOQ of 20 ng/mL. No interferences were seen at selectivity tests. Matrix effect was lower than 22.9 % and inaccuracy, intra-, and inter-run imprecision were better than 15.4 %. No carryover was observed and stability study was successfully applied for processed samples maintained in the autosampler at 10 degrees C for 24 h The method was applied for four authentic samples from individuals under gefitinib treatment, detecting gefitinib from 104.6 ng/mL to 777.1 ng/mL and O-desmethylgefitinib from 85.2 ng/mL to 499.2 ng/mL. Finally, the greenness characteristic was evaluated by three tools, achieving satisfactory results that confirm its compliance to GAC principles.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] An automated high-throughput LC/LC-MS/MS platform for the clinical therapeutic drug monitoring of immunosuppressants
    Zhang, YL
    Dai, K
    DeSilva, C
    Armstrong, M
    Bendrick-Peart, J
    Christians, U
    THERAPEUTIC DRUG MONITORING, 2005, 27 (02) : 244 - 245
  • [32] Comparison of LC-MS/MS and Nanoparticle Immunoassay Method for Paclitaxel Determination Applied in Therapeutic Drug Monitoring
    Geng, Chunmei
    Li, Pingli
    Chen, Xuwang
    Gao, Meimei
    Zhang, Rui
    Kan, Zhihui
    Shaikh, Abdul S.
    Bu, Fanlong
    Guo, Ruichen
    LATIN AMERICAN JOURNAL OF PHARMACY, 2017, 36 (07): : 1316 - 1321
  • [33] A Validated LC-MS/MS Method for the Determination of Mezlocillin in Plasma: An Adapted Method for Therapeutic Drug Monitoring in Children
    Tang, Bo-Hao
    Kan, Min
    Yang, Xin-Mei
    Wang, Rong-Hua
    Shi, Hai-Yan
    Zheng, Yi
    Hao, Guo-Xiang
    Song, Lin-Lin
    Zhao, Wei
    CURRENT PHARMACEUTICAL ANALYSIS, 2021, 17 (07) : 853 - 860
  • [34] Development of LC-MS/MS method and application to bioequivalence study of a light sensitive drug montelukast
    Wong, Emily Yii Ling
    Loh, Gabriel Onn Kit
    Tan, Yvonne Tze Fung
    Peh, Kok Khiang
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2021, 47 (02) : 197 - 206
  • [35] Alternative matrices for therapeutic drug monitoring of immunosuppressive agents using LC-MS/MS
    Ghareeb, Mwlod
    Akhlaghi, Fatemeh
    BIOANALYSIS, 2015, 7 (08) : 1037 - 1058
  • [36] Multiplexed therapeutic drug monitoring of antipsychotics in dried plasma spots by LC-MS/MS
    Ruggiero, Carla
    Ramirez, Stefania
    Ramazzotti, Eric
    Mancini, Rita
    Muratori, Roberto
    Raggi, Maria Augusta
    Conti, Matteo
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (08) : 1440 - 1449
  • [37] Validation and application of a LC-MS/MS method for illicit drug determination in wastewater
    Kuloglu, Merve
    Mercan, Selda
    Tekin, Tugba
    Turkmen, Zeynep
    Asicioglu, Faruk
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [38] An LC-MS/MS method for the simultaneous determination of 18 antibacterial drugs in human plasma and its application in therapeutic drug monitoring
    Lu, Wei
    Pan, Meng
    Ke, Hongqin
    Liang, Jun
    Liang, Wenbin
    Yu, Ping
    Zhang, Penghua
    Wang, Qibin
    FRONTIERS IN PHARMACOLOGY, 2022, 13
  • [39] Method development and validation of cabozantinib by LC-MS/MS
    Venkateshwarlu, Punna
    Patel, Mehul M.
    PHARMACIA, 2022, 69 (02) : 407 - 413
  • [40] Quantification of 4 antidepressants and a metabolite by LC-MS for therapeutic drug monitoring
    Choong, Eva
    Rudaz, Serge
    Kottelat, Astrid
    Haldemann, Sophie
    Guillarme, Davy
    Veuthey, Jean-Luc
    Eap, Chin B.