共 50 条
Performance evaluation and optimization of a distributed generation system integrating high-temperature proton exchange membrane fuel cell and recuperative-regenerative Organic Rankine Cycle
被引:0
|作者:
Xu, Shiyi
[1
]
Leng, Shuang
[1
]
Xie, Junen
[1
]
Liu, Zekuan
[1
]
Li, Chengjie
[1
]
Wang, Jingyi
[3
]
Chen, Zhengjian
[4
]
Liao, Mei
[4
]
Qin, Jiang
[1
,2
]
机构:
[1] Harbin Inst Technol, Sch Energy Sci & Engn, Harbin 150001, Peoples R China
[2] Harbin Inst Technol, Chongqing Res Inst, Chongqing 401120, Peoples R China
[3] Harbin Inst Technol, Sch Sci, Shenzhen 518055, Peoples R China
[4] Shenzhen Energy Grp Co Ltd, Shenzhen 518000, Peoples R China
来源:
基金:
中国国家自然科学基金;
关键词:
High-temperature proton exchange membrane fuel cells;
Distributed generation systems;
Recuperative-regenerative Organic Rankine;
Cycle;
Two-objective optimization;
Economic analysis;
WORKING FLUID SELECTION;
HYBRID POWER-SYSTEM;
HEAT;
PEMFC;
ENERGY;
D O I:
10.1016/j.energy.2025.134967
中图分类号:
O414.1 [热力学];
学科分类号:
摘要:
Improving the electrical efficiency of distributed generation systems based on high-temperature proton exchange membrane fuel cells (HT-PEMFC) is essential for its promotion. This paper proposes a distributed generation system that uses the recuperative-regenerative Organic Rankine Cycle (RR-ORC) to recover waste heat from the HT-PEMFC for electricity generation. To further increase the evaporation temperature of the RR-ORC, it innovatively utilizes organic fluid to replace conventional coolants for stack cooling. The energy, exergy, and economic analysis method is adopted to evaluate the system performance comprehensively. The results suggest that toluene is an optimal organic fluid. Under the typical condition, the total cost per hour, the net power, and the energy efficiency of this novel system are 44.86 $/h, 119.66 kW, and 49.48 %, respectively. Compared with the conventional system integrating HT-PEMFC and ORC, the system net power can be improved by 7.55 %. Moreover, the parameterization results suggest that the current density, fuel cell temperature, cathode stoichiometry, and pinch point temperature difference of the condenser can significantly affect the system performance. On this basis, the optimal design parameters under which the total cost per hour and the system exergy efficiency are 44.88 $/h and 53.87 %, respectively, have been obtained through a two-objective optimization.
引用
收藏
页数:15
相关论文