Investigating classical χ2 test methods for high-precision calibration of radiocarbon measurements

被引:0
|
作者
Scifo, Andrea [1 ]
Dee, Michael [1 ]
机构
[1] Univ Groningen, Ctr Isotope Res, Nijenborgh 6, NL-9747 AG Groningen, Netherlands
基金
欧洲研究理事会;
关键词
age estimations; Bayesian analysis; calibration; radiocarbon dating;
D O I
10.1017/RDC.2025.9
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Sudden annual rises in radiocarbon concentration have proven to be valuable assets for achieving exact-year calibration of radiocarbon measurements. These extremely precise calibrations have usually been obtained through the use of classical chi 2 tests in conjunction with a local calibration curve of single-year resolution encompassing a rapid change in radiocarbon levels. As the latest Northern Hemisphere calibration curve, IntCal20, exhibits single-year resolution over the last 5000 years, in this study we investigate the possibility of performing calibration of radiocarbon dates using the classical chi 2 test and achieving high-precision dating more extensively, examining scenarios without the aid of such abrupt changes in radiocarbon concentration. In order to perform a broad analysis, we simulated 171 sets of radiocarbon measurements over the last two millennia, with different set lengths and sample spacings, and tested the effectiveness of the chi 2 test compared to the most commonly used Bayesian wiggle-matching technique for temporally ordered sequences of samples such as tree-rings sequences, the OxCal D_Sequence. The D_Sequence always produces a date range, albeit in certain cases very narrow; the chi 2 test proves to be a viable alternative to Bayesian wiggle-matching, as it achieves calibrations of comparable precision, providing also a highest-likelihood estimate within the uncertainty range.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] MICADAS: ROUTINE AND HIGH-PRECISION RADIOCARBON DATING
    Wacker, L.
    Bonani, G.
    Friedrich, M.
    Hajdas, I.
    Kromer, B.
    Nemec, M.
    Ruff', M.
    Suter, M.
    Synal, H-A
    Vockenhuber, C.
    RADIOCARBON, 2010, 52 (02) : 252 - 262
  • [22] Calibration and self-validation of thermistors for high-precision temperature measurements
    Rudtsch, Steffen
    von Rohden, Christoph
    MEASUREMENT, 2015, 76 : 1 - 6
  • [23] HIGH-PRECISION DECADAL CALIBRATION OF THE RADIOCARBON TIME SCALE, AD 1950-2500 BC
    STUIVER, M
    BECKER, B
    RADIOCARBON, 1986, 28 (2B) : 863 - 910
  • [24] HIGH-PRECISION DECADAL CALIBRATION OF THE RADIOCARBON TIME SCALE, AD 1950-6000 BC
    STUIVER, M
    BECKER, B
    RADIOCARBON, 1993, 35 (01) : 35 - 65
  • [25] HIGH-PRECISION AMS RADIOCARBON MEASUREMENTS OF CENTRAL ARCTIC-OCEAN SEA WATERS
    JONES, GA
    GAGNON, AR
    VONREDEN, KF
    MCNICHOL, AP
    SCHNEIDER, RJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 92 (1-4): : 426 - 430
  • [26] High-precision atomic mass measurements for a CKM unitarity test
    Eronen, Tommi
    Jokinen, Ari
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 349 : 69 - 73
  • [27] High-Precision Assessment and Calibration of Polarimetric RADARSAT-2 SAR Using Transponder Measurements
    Touzi, Ridha
    Hawkins, R. K.
    Cote, Stephane
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (01): : 487 - 503
  • [28] A High-Precision Calibration Method for Spectrometers
    Perret, Edith
    Balmer, Tobias E.
    AMERICAN LABORATORY, 2011, 43 (05) : 44 - 45
  • [29] High-Precision Calibration Scheme for RIMU
    Cheng, Jianhua
    Liu, Ping
    Gao, Peng
    Zou, Mingfeng
    Fu, Wenhuan
    IEEE ACCESS, 2019, 7 : 72376 - 72386
  • [30] High-precision measurements of reflectance
    Voarino, Philippe
    Petitrenaud, Sebastien
    Piombini, Herve
    Sabary, Frederic
    Marteau, Daniel
    INTERNATIONAL OPTICAL DESIGN CONFERENCE 2006, PTS 1 AND 2, 2006, 6342