Visual and refractive outcomes of trocar-assisted intrascleral three-piece intraocular lens fixation

被引:0
|
作者
Pellegrini, Marco [1 ,2 ,3 ]
Adamo, Ginevra [1 ,2 ]
Nardella, Michele [1 ,2 ]
Sarti, Laura [1 ,2 ]
Talli, Pietro Maria [1 ]
Nasini, Francesco [1 ]
Mura, Marco [1 ,4 ]
机构
[1] Univ Ferrara, St Anna Univ Hosp, Ferrara, Italy
[2] Osped Privati Forli Villa Igea, Dept Ophthalmol, Forli, Italy
[3] Ist Int Ric & Formaz Oftalmol IRFO, Forli, Italy
[4] King Khalid Eye Specialist Hosp, Riyadh, Saudi Arabia
关键词
Intrascleral fixation; scleral fixation; secondary IOL implant; IOL power calculation; SCLERAL FIXATION; ACCURACY;
D O I
10.1177/11206721241304156
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To report the visual and refractive outcomes of trocar-assisted sutureless intrascleral three-piece intraocular lens (IOL) fixation, and to compare the accuracy of different IOL power formulas in this setting. Methods Twenty eyes of 20 patients who underwent trocar-assisted sutureless three-piece IOL scleral fixation were included. Two trocar-cannula systems were placed at 3 and 9 o'clock position creating 2.5 mm scleral tunnels. The haptics of a three-piece IOL were grasped with serrated retinal forceps, externalized through the scleral tunnels and fixed by making a flange. Prediction error (PE) was calculated as the actual postoperative spherical equivalent (SE) refraction minus the SE predicted refraction. The predicted SE was calculated using the Barret Universal II, Emmetropia Verifying Optical (EVO), Hoffer Q, Holladay 1, Holladay II, and SRK/T. Results At 6 months after surgery, corrected distance visual acuity improved from 0.66 +/- 0.36 to 0.17 +/- 0.13 logMAR (p < .001). The lowest median absolute PE was obtained by the Barrett formula (0.73D), followed by the EVO (0.81D), Holladay 1 (0.94D), SRK/T (0.98D), Hoffer Q (1.05D) and Haigis (1.64D) formulas. The highest percentage of eyes within +/- 1.00 D were obtained with the Barrett (60.0%), and EVO (55.0%) formulas. Conclusion Although trocar-assisted intrascleral three-piece IOL fixation yields good visual results, the predictability of refractive outcomes is lower than in standard cataract surgery. All formulas showed a slight tendency towards a hyperopic refractive surprise.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Refractive Outcomes AfterScleral Fixation of the Carlevale Intraocular Lens
    Courat, Nathan
    Gobert, Frederic
    Naudin, Thibault
    Ducloux, Alexandre
    Alleyrat, Camille
    Leveziel, Nicolas
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (08)
  • [42] Adjustment of intraocular lens tilt during intrascleral fixation assisted by intraoperative OCT
    Fukumoto, Ryuki
    Inoue, Makoto
    Ishida, Tomoka
    Koto, Takashi
    Hirakata, Akito
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (10): : 1308 - 1313
  • [43] Sutureless Intrascleral Intraocular Lens Fixation Using a Microtube-Assisted Technique
    Yuda, Kentaro
    Shimizu, Toshiki
    Hayashi, Takahiko
    Yuda, Kenji
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 : 39 - 43
  • [44] Modified Intrascleral Fixation for Repositioning the Dislocated Single-Piece, Rigid PMMA Intraocular Lens
    Zong, Yuan
    Wu, Kaicheng
    Fang, Wangyi
    Yu, Jian
    Jiang, Chunhui
    Xu, Gezhi
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (06): : 1019 - 1023
  • [45] Peripheral Intravascular Catheter-Assisted Sutureless Scleral Fixation of Three-Piece Intraocular Lenses: A Novel Technique
    Radice, Paolo
    Carini, Elisa
    Matteucci, Martina
    Ranno, Stefano
    Lucchini, Sara
    Govetto, Andrea
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (12): : 2096 - 2100
  • [46] The effects of three-piece or single-piece acrylic intraocular lens implantation on posterior capsule opacification
    Bilge, AH
    Aykan, Ü
    Akin, T
    Ünsal, U
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2004, 14 (05) : 375 - 380
  • [47] Intraocular Lens Position Following In-the-Bag Implantation of Single-Piece Versus Three-Piece Acrylic Intraocular Lenses
    Robert, Marie-Claude
    Harasymowycz, Paul
    OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (06) : 472 - 478
  • [48] Late-Onset Spontaneous Haptic Disinsertion from a Three-Piece Intraocular Lens
    Chuang, Chih-Chun
    Lee, Jiahn-Shing
    Lin, Ken-Kuo
    Hsiao, Ching-Hsi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2010, 54 (05) : 500 - 502
  • [49] Late-onset spontaneous haptic disinsertion from a three-piece intraocular lens
    Chih-Chun Chuang
    Jiahn-Shing Lee
    Ken-Kuo Lin
    Ching-Hsi Hsiao
    Japanese Journal of Ophthalmology, 2010, 54 : 500 - 502
  • [50] Iris suture fixation of out-of-the-bag dislocated three-piece intraocular lenses
    Armonaite, Laura
    Lofgren, Stefan
    Behndig, Anders
    ACTA OPHTHALMOLOGICA, 2019, 97 (06) : 583 - 588