Objective Isometric muscle strength testing is easier to apply, but isokinetic test results are deemed to offer a better transfer for training purposes. This systematic review aims to elucidate differences in terms of validity and reliability, if any, between isometric and isokinetic approaches. Material and Methods In January 2024, the PubMed database was searched for studies reporting reliability or validity measures for healthy adults for both isokinetic and isometric strength testing devices. Investigations of certain handheld types of dynamometers or publications older than 30 years were excluded. Results Thirteen studies met the inclusion criteria. Isometric maximal strength testing tended to demonstrate higher short-term reliability coefficients (ICC: 0.87-0.96) compared to isokinetic approaches (ICC: 0.69-0.99), while absolute measures for reproducibility were somehow similar for isometric (CV: 6.9-9.4%, SEM: 4.5-11.0%) and isokinetic testing (CV: 2.3-12.4%,SEM: 4.8-14.0%). Validity was confirmed for both isometric and isokinetic testing, but correlation coefficients varied markedly depending on the external criteria (EMG r>0.9, 5-10-RM r>0.8, Cross Sectional Area r>0.7, specific isokinetic comparisons r>0.5). Conclusions Confirming general validity for both, existing evidence suggests negligible advantages for isometric compared to isokinetic devices in terms of reproducibility measures. Future research should address comparisons seeking for side-effect properties of novel isometric and isokinetic devices such as accessibility of normative data for certain populations or time economy.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Reliability of Isokinetic Assessment of Shoulder-Rotator Strength: A Systematic Review of the Effect of Position
    Edouard, Pascal
    Samozino, Pierre
    Julia, Marc
    Cervera, Sophie Gleizes
    Vanbiervliet, William
    Calmels, Paul
    Gremeaux, Vincent
    JOURNAL OF SPORT REHABILITATION, 2011, 20 (03) : 367 - 383
  • [22] Validity and reliability of Squegg device in measuring isometric handgrip strength
    Bairapareddy, K. C.
    Khaleel, A.
    Akbar, S.
    Maherban, H.
    Mehdiyeva, F.
    Rasti, F.
    Tamim, M.
    Abdelbasset, W. K.
    Ezzat, W.
    Reddy, R. S.
    Tedla, J. S.
    Ramakrshnan, S.
    Hussein, R. S.
    Alaparthi, G. K.
    Elsayed, S. H.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (21) : 10247 - 10254
  • [23] ISOKINETIC, ISOMETRIC AND ISOTONIC STRENGTH RELATIONSHIPS
    KNAPIK, JJ
    WRIGHT, JE
    MAWDSLEY, RH
    BRAUN, JM
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1983, 64 (02): : 77 - 80
  • [24] Reliability of isometric subtalar pronator and supinator strength testing
    Hagen, Marco
    Lahner, Matthias
    Winhuysen, Martin
    Maiwald, Christian
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2015, 8
  • [25] Reliability of isometric subtalar pronator and supinator strength testing
    Marco Hagen
    Matthias Lahner
    Martin Winhuysen
    Christian Maiwald
    Journal of Foot and Ankle Research, 8
  • [26] An Isometric Strength Testing Device for Use with the Elderly: Validation Compared with Isokinetic Measures
    Hutchison, Alexander
    Clarke, Mark
    PHYSICAL & OCCUPATIONAL THERAPY IN GERIATRICS, 2006, 25 (02) : 1 - 12
  • [27] RELIABILITY OF ISOKINETIC TESTING OF HIP MUSCLE STRENGTH IN YOUNG BOYS
    BURNETT, CN
    FILUSCH, EM
    KING, WM
    PHYSICAL THERAPY, 1987, 67 (05): : 746 - 747
  • [28] Reliability of lower extremity isokinetic strength testing in adults with stroke
    Pohl, PS
    Startzell, JD
    Duncan, PW
    Wallace, D
    CLINICAL REHABILITATION, 2000, 14 (06) : 601 - 607
  • [29] MYOTEST - AN ISOKINETIC AND ISOMETRIC TESTING DEVICE
    MOHADJER, S
    DITTMAR, A
    MAZET, J
    MACHETPIETROPAOLI, H
    DEJOUR, H
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (03) : 264 - 268
  • [30] FUNCTIONAL PERFORMANCE TESTING OF THE HIP IN ATHLETES: A SYSTEMATIC REVIEW FOR RELIABILITY AND VALIDITY
    Kivlan, Benjamin R.
    Martin, RobRoy L.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2012, 7 (04): : 402 - 412