Low-Intensity Ultrasound Tibial Nerve Stimulation Suppresses Bladder Activity in Rats

被引:0
|
作者
He, Zitian [1 ,2 ,3 ]
Liu, Qinggang [2 ,4 ,5 ]
Yang, Ruiyao [2 ]
Zhou, Yongheng [2 ,4 ,5 ]
Liu, Xin [2 ,4 ,5 ]
Deng, Han [2 ,6 ]
Cong, Huiling [2 ,6 ]
Liu, Yixi [2 ,6 ]
Liao, Limin [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Wenzhou Med Univ, Yuying Childrens Hosp, Affiliated Hosp 2, Dept Rehabil, Wenzhou, Zhejiang, Peoples R China
[2] China Rehabil Res Ctr, Dept Urol, Beijing, Peoples R China
[3] Wenzhou Med Univ, Clin Med Coll 2, Wenzhou, Zhejiang, Peoples R China
[4] Shandong Univ, Cheeloo Coll Med, Jinan, Shandong, Peoples R China
[5] Univ Hlth & Rehabil Sci, Qingdao, Shandong, Peoples R China
[6] Capital Med Univ, Sch Rehabil, Beijing, Peoples R China
来源
NEUROMODULATION | 2025年 / 28卷 / 01期
基金
中国国家自然科学基金;
关键词
Bladder activity; cystometry; low-intensity ultrasound; rats; tibial nerve stimulation; OVERACTIVE BLADDER; MICTURITION REFLEX; NEUROMODULATION; THERAPY;
D O I
10.1016/j.neurom.2024.06.005
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background and Objective: Noninvasive neuromodulation, particularly through low-intensity ultrasound, holds promise in the fields of neuroscience and neuro-engineering. Ultrasound can stimulate the central nervous system to treat neurologic disorders of the brain and activate peripheral nerve activity. The aim of this study is to investigate the inhibitory effect of low-intensity ultrasonic tibial nerve stimulation on both the physiological state and the overactive bladder (OAB) model in rats. Materials and Methods: A total of 28 female Sprague-Dawley rats were used in this study. Continuous transurethral instillation of 0.9% normal saline into the bladder was initially performed to stimulate physiological bladder activity. Subsequently, a solution containing 0.3% acetic acid dissolved in saline was instilled to induce rat models of OAB. The study comprised two phases: initial observation of bladder response to low-intensity ultrasound (1 MHz, 1 W/cm2, 50% duty cycle) in seven rats; subsequent exploration of ultrasound frequency (3 MHz) and intensity (2 W/cm2 and 3 W/cm2) effects in 21 rats. The intercontraction intervals (ICIs) were the primary outcome measure. Histologic analysis of tibial nerves and surrounding muscle tissues determined safe ultrasound parameters. Results: Low-intensity ultrasound tibial nerve stimulation significantly inhibited normal and OAB activity. Ultrasound stimulation at 1 MHz, 1 W/cm2, with a 50% duty cycle significantly prolonged the ICI in both normal (p < 0.0001) and OAB rats (p < 0.01), as did transitioning to a 3 MHz frequency (p = 0.001 for normal rats; p < 0.01 for OAB rats). Similarly, at an intensity of 2 W/cm2 and 1 MHz frequency with a 50% duty cycle, ultrasound stimulation significantly prolonged the ICI in both normal (p < 0.01) and OAB rats (p < 0.005). Furthermore, switching to a 3 W/cm2 ultrasound intensity also significantly extended the ICI in both normal (p < 0.05) and OAB rats (p = 0.01). However, after different ultrasound intensities and frequencies, there was no statistical difference in ICI ratios (preultrasound stimulation vs postultrasound stimulation/preultrasound stimulation * 100%) in all rats (p > 0.05). Lowintensity ultrasound tibial nerve stimulation did not influence baseline pressure, threshold pressure, or maximum pressure. In addition, a latency period in bladder reflex inhibition was induced by low-intensity ultrasound tibial nerve stimulation in some rats. Histologic analysis indicated no evident nerve or muscle tissue damage or abnormalities. Conclusions: This study confirmed the potential of transcutaneous ultrasound tibial nerve stimulation to improve bladder function. According to the findings, the ultrasonic intensities ranging from 1 to 3 W/cm2 and frequencies of 1 MHz and 3 MHz are both feasible and safe treatment parameters. This study portended the promise of low-intensity ultrasound tibial nerve stimulation as a treatment for OAB and provides a basis and reference for future clinical applications.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 50 条
  • [21] Low-intensity ultrasound stimulation to enhance the recellularization of corneal stroma
    Melchor, J.
    Bochud, N.
    Peralta, L. M.
    Rus, G.
    Gonzalez Andrades, M.
    Alaminos, M.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2012, 6 : 138 - 138
  • [22] Neuroprotective Effect of Low-Intensity Transcranial Ultrasound Stimulation in Moderate Traumatic Brain Injury Rats
    Zheng, Tao
    Du, Juan
    Yuan, Yi
    Wu, Shuo
    Jin, Yinglan
    Wang, Zhanqiu
    Liu, Defeng
    Shi, Qinglei
    Wang, Xiaohan
    Liu, Lanxiang
    FRONTIERS IN NEUROSCIENCE, 2020, 14
  • [23] In vitro effects of low-intensity ultrasound stimulation on the bone cells
    Sun, JS
    Hong, RC
    Chang, WHS
    Chen, LT
    Lin, FH
    Liu, HC
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 57 (03): : 449 - 456
  • [24] Low-Intensity Focused Ultrasound Stimulation Treatment Decreases Blood Pressure in Spontaneously Hypertensive Rats
    Li, Dapeng
    Cui, Zhiwei
    Xu, Shanshan
    Xu, Tianqi
    Wu, Shan
    Bouakaz, Ayache
    Wan, Mingxi
    Zhang, Siyuan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (11) : 3048 - 3056
  • [25] Improvement of the activity of anaerobic sludge by low-intensity ultrasound
    Xie, Beizhen
    Liu, Hong
    Yan, Yixin
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2009, 90 (01) : 260 - 264
  • [26] Blood Pressure Modulation With Low-Intensity Focused Ultrasound Stimulation to the Vagus Nerve: A Pilot Animal Study
    Ji, Ning
    Lin, Wan-Hua
    Chen, Fei
    Xu, Lisheng
    Huang, Jianping
    Li, Guanglin
    FRONTIERS IN NEUROSCIENCE, 2020, 14
  • [27] Low-intensity pulsed ultrasound shortens the treatment time in tibial distraction osteogenesis
    Khaled Hamed Salem
    Andreas Schmelz
    International Orthopaedics, 2014, 38 : 1477 - 1482
  • [28] The effect of low-intensity pulsed ultrasound on callus maturation in tibial distraction osteogenesis
    Hani El-Mowafi
    Mona Mohsen
    International Orthopaedics, 2005, 29 : 121 - 124
  • [29] No effect of low-intensity ultrasound on healing time of intramedullary fixed tibial fractures
    Emami, A
    Petrén-Mallmin, M
    Larsson, S
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (04) : 252 - 257
  • [30] Complex tibial fracture outcomes following treatment with low-intensity pulsed ultrasound
    Leung, KS
    Lee, WS
    Tsui, HF
    Liu, PPL
    Cheung, WH
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (03): : 389 - 395