Verification of the Vitek Reveal System for Direct Antimicrobial Susceptibility Testing in Gram-Negative Positive Blood Cultures

被引:1
|
作者
Menchinelli, Giulia [1 ]
Squitieri, Damiano [2 ]
Magri, Carlotta [2 ]
De Maio, Flavio [1 ]
D'Inzeo, Tiziana [1 ,2 ]
Cacaci, Margherita [2 ]
De Angelis, Giulia [1 ,2 ]
Sanguinetti, Maurizio [1 ,2 ]
Posteraro, Brunella [2 ,3 ]
机构
[1] Fdn Policlin Univ A Gemelli IRCCS, Dipartimento Sci Lab Ematolog, I-00168 Rome, Italy
[2] Univ Cattolica Sacro Cuore, Dipartimento Sci Biotecnol Base, Clin Intensivol & Perioperatorie, I-00168 Rome, Italy
[3] Fdn Policlin Univ A Gemelli IRCCS, Unita Operativa Med Precis Microbiol Clin, Direz Sci, I-00168 Rome, Italy
来源
ANTIBIOTICS-BASEL | 2024年 / 13卷 / 11期
关键词
antimicrobial susceptibility testing; blood cultures; international standard for organization; verification; Vitek Reveal assay; PSEUDOMONAS-AERUGINOSA; ENTEROBACTERIACEAE;
D O I
10.3390/antibiotics13111058
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background/Objectives: The International Organization for Standardization (ISO) 20776-2:2021, which replaces ISO 20776-2:2007, focuses solely on the performance of antimicrobial susceptibility testing (AST) assays, emphasizing the ISO 20776-1 broth microdilution method as the reference standard. Consequently, categorical agreement (CA) and associated errors should not be applied. We verified the Vitek Reveal AST assay according to both ISO 20776-2:2021 and ISO 20776-2:2007 criteria. Methods: Samples from 100 simulated and clinical Gram-negative (GN) positive blood cultures (PBCs) were tested at a large teaching hospital. The simulated GN-PBCs were obtained from a hospital collection of isolates selected to represent diverse antimicrobial resistance profiles. The Reveal assay results were compared with those from the reference assay, and the time to result (TTR) for the Reveal assay was calculated. Results: The essential agreement rates were 96.1% (816/849) for simulated and 98.8% (929/940) for clinical GN-PBC samples. The bias values were -3.1 for simulated and -11.0 for clinical samples. The CA rates were 97.7% (808/827) for simulated and 99.2% (924/931) for clinical samples. The mean TTR +/- SD (hours) for resistant organisms was significantly lower (4.40 +/- 1.15) than that for susceptible, increased exposure (5.52 +/- 0.48) and susceptible (5.54 +/- 0.49) organisms. Conclusions: Our findings reinforce the potential of the Reveal assay as a valuable tool and support its implementation in clinical microbiology laboratories.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Performance of the Reveal Rapid Antibiotic Susceptibility Testing System on Gram-Negative Blood Cultures at a Large Urban Hospital
    Tibbetts, Robert
    George, Sheeja
    Burwell, Reece
    Rajeev, Lara
    Rhodes, Paul A.
    Singh, Pragya
    Samuel, Linoj
    JOURNAL OF CLINICAL MICROBIOLOGY, 2022, 60 (06)
  • [22] Pilot study evaluation of the eQUANTTM system for accelerated antimicrobial susceptibility testing of gram-negative organisms directly from positive blood cultures
    Abdelhamed, Ayman M.
    Alkins, Brenda R.
    Deak, Eszter
    Rajan, Nitin
    Good, Caryn E.
    Hoyos-Urias, Adrian
    Kimball, Simon R.
    Putney, Suzanne
    Moreno, Angel
    Knopfmacher, Oren
    Banaei, Niaz
    Herget, Meike
    Granato, Paul A.
    Jacobs, Michael R.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2025, 111 (03)
  • [23] Direct antimicrobial susceptibility testing of positive blood cultures: a comparison of the Accelerate Pheno™ and VITEK® 2 systems
    Schneider, Jack G.
    Wood, James B.
    Smith, Nathan W.
    Emery, Christopher L.
    Davis, Thomas E.
    Manaloor, John J.
    Bocian, Brittany
    Schmitt, Bryan H.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2019, 95 (03)
  • [24] Accuracy of Direct Antimicrobial Susceptibility Testing of Gram-Negative Bacteria from Positive Blood Cultures Using MicroScan System and Value of Using Expert Rules for β-Lactam Agents
    Jacobs, Michael R.
    Good, Caryn E.
    Abdelhamed, Ayman M.
    Bonomo, Robert A.
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2022, 66 (03)
  • [25] Rapid identification and antimicrobial susceptibility profiling of Gram-positive cocci in blood cultures with the Vitek 2 system
    Lupetti, A.
    Barnini, S.
    Castagna, B.
    Capria, A. -L.
    Nibbering, P. H.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2010, 29 (01) : 89 - 95
  • [26] Rapid identification and antimicrobial susceptibility profiling of Gram-positive cocci in blood cultures with the Vitek 2 system
    A. Lupetti
    S. Barnini
    B. Castagna
    A.-L. Capria
    P. H. Nibbering
    European Journal of Clinical Microbiology & Infectious Diseases, 2010, 29 : 89 - 95
  • [27] Performance of the LifeScale automated rapid phenotypic antimicrobial susceptibility testing on Gram-negative rods directly from positive blood cultures
    Snyder, James W.
    Chaudhry, Nadia
    Hoffmann, Wesley
    JOURNAL OF CLINICAL MICROBIOLOGY, 2024, 62 (12)
  • [28] Rapid identification and susceptibility testing of Gram-positive cocci in BacT/ALERT blood cultures by direct inoculation into the Vitek 2 system
    Barreales Fonseca, Alicia
    Lara Perez, Magdalena
    Hernandez Caceres, Isabel
    Diez Gil, Oscar
    REVISTA ESPANOLA DE QUIMIOTERAPIA, 2011, 24 (03) : 131 - 135
  • [29] Evaluation of the Accelerate Pheno System for Fast Identification and Antimicrobial Susceptibility Testing from Positive Blood Cultures in Bloodstream Infections Caused by Gram-Negative Pathogens
    Marschal, Matthias
    Bachmaier, Johanna
    Autenrieth, Ingo
    Oberhettinger, Philipp
    Willmann, Matthias
    Peter, Silke
    JOURNAL OF CLINICAL MICROBIOLOGY, 2017, 55 (07) : 2116 - 2126
  • [30] Evaluation of the VITEK® 2 system for testing of Gram-negative bacilli directly from BacT/Alert Fan blood cultures
    Ullberg, M.
    Bergstrom, J.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S487 - S487