Effects of wire rope isolators on seismic life-cycle cost of UHV bypass switch

被引:1
|
作者
He, Chang [1 ,2 ,3 ]
He, Kunning [2 ]
Jiang, Liqiang [1 ,3 ]
Xie, Qiang [2 ]
Yang, Zhenyu [4 ]
机构
[1] Cent South Univ, Sch Civil Engn, Changsha, Peoples R China
[2] Tongji Univ, Coll Civil Engn, 1239 Siping St, Shanghai 200092, Peoples R China
[3] Natl Engn Res Ctr High Speed Railway Construct Tec, Changsha, Peoples R China
[4] Guangzhou Univ, Earthquake Engn Res & Test Ctr, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
UHV bypass switch; Seismic life-cycle cost; Seismic cost risk; Seismic cost vulnerability; DESIGN CRITERIA; BASE-ISOLATION; BUILDINGS; OPTIMIZATION; PERFORMANCE; MODEL;
D O I
10.1016/j.ijdrr.2024.104917
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
The seismic isolation devices reduce the seismic vulnerability of the electrical equipment. Accurately assessing the seismic life-cycle cost (SLCC) of the electrical equipment is beneficial in guiding the design and enhancing the seismic resilience of electrical substations and converter stations. To evaluate the effects of the isolator devices on the seismic life-cycle cost of electrical equipment, a SLCC evaluation model was proposed in this study, and the evaluation was conducted on an ultra-high voltage (UHV) bypass switch (BPS) with wire rope isolators (WRI). The model takes into account equipment purchase, maintenance, transportation and installation costs and indirect losses caused by power outages. Afterward, the SLCC and break-even time of the UHV BPS with and without WRIs in different regions were analyzed. The results indicate that beyond the break-even time, the BPS with WRIs becomes more economically viable. Moreover, its economic viability increases as the service life extends. Therefore, in high seismic cost risk areas, it is recommended to adopt seismic isolation devices to ensure the secure and economically efficient operation of electrical equipment.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Numerical investigation of the seismic response of a UHV composite bypass switch retrofitted with wire rope isolators
    Yang, Zhenyu
    Xie, Qiang
    He, Chang
    Xue, Songtao
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2021, 20 (01) : 275 - 290
  • [2] Numerical investigation of the seismic response of a UHV composite bypass switch retrofitted with wire rope isolators
    Zhenyu Yang
    Qiang Xie
    Chang He
    Songtao Xue
    Earthquake Engineering and Engineering Vibration, 2021, 20 : 275 - 290
  • [3] Numerical investigation of the seismic response of a UHV composite bypass switch retrofitted with wire rope isolators
    Yang Zhenyu
    Xie Qiang
    He Chang
    Xue Songtao
    EarthquakeEngineeringandEngineeringVibration, 2021, 20 (01) : 275 - 290
  • [4] Wire Rope Isolators for Seismic Base Isolation
    Prost, Claude
    Abdelnour, Bruno
    SOUND AND VIBRATION, 2018, 52 (05): : 2 - 5
  • [5] Using Wire Rope Isolators for Seismic Protection
    Prost, Claude
    Partyka, Joshua
    SOUND AND VIBRATION, 2016, 50 (05): : 8 - 11
  • [6] Life-cycle cost based design of bridge lead-rubber isolators in seismic regions
    Asadi, Payam
    Nikfar, Davood
    Hajirasouliha, Iman
    STRUCTURES, 2020, 27 : 383 - 395
  • [7] Optimal seismic design based on life-cycle cost
    Wen, YK
    Kang, YJ
    OPTIMAL PERFORMANCE OF CIVIL INFRASTRUCTURE SYSTEMS, 1998, : 194 - 210
  • [8] Seismic performance assessment of buildings based on life-cycle cost
    Dang, Yu, 1600, Chinese Society of Civil Engineering (47):
  • [9] Life-cycle seismic repair cost assessment and sensitivity analysis
    Taflanidis, A. A.
    APPLICATIONS OF STATISTICS AND PROBABILITY IN CIVIL ENGINEERING, 2011, : 943 - 951
  • [10] Life-cycle cost analysis for an incremental seismic rehabilitation project
    Loa, Gustavo
    Munoz, Alejandro
    Santa-Cruz, Sandra
    EARTHQUAKE SPECTRA, 2021, 37 (04) : 2840 - 2856