Observational Analysis of Point-of-Care Lactate Plus™ Meter in Preclinical Trauma Models

被引:0
|
作者
Gaeth, Catharina [1 ]
Duarte, Jamila [1 ]
Rodriguez, Alvaro [1 ]
Powers, Amber [1 ]
Stone II, Randolph [1 ]
机构
[1] United States Army Inst Surg Res, Combat Wound Care, 3698 Chambers Pass,JBSA Ft Sam Houston, Houston, TX 78234 USA
关键词
point of care; lactate; prehospital; preclinical trauma models; swine; whole blood; PREHOSPITAL SERUM LACTATE; SYSTOLIC BLOOD-PRESSURE; MORTALITY; ACCURACY; PREDICTOR; OUTCOMES;
D O I
10.3390/diagnostics14232641
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Blood lactate concentration is often used to assess systemic hypoperfusion, tissue hypoxia, and sepsis in trauma patients and serves as a prognostic indicator and marker of response to therapy. Point-of-care (POC) devices provide rapid lactate measurements with a single drop of blood. In this study, lactate values from whole blood, measured with two POC devices, Abbott i-STAT (R) and the Nova Biomedical Lactate (LA) Plus (TM) meter, are compared. Methods: An observational analysis of 760 blood samples from four preclinical trauma animal models was performed. Lactate was measured simultaneously with two POC devices (i-STAT (R) and the Lactate Plus (TM) meter). The evaluation in the form of a Bland-Altman diagram showed the agreement of the tests. Results: The Spearman correlation was 0.9180 (95% CI 0.9056 to 0.9288) for i-STAT (R) vs. the LA Plus (TM) meter. Both tests showed a significant increase in lactate after injury (p < 0.05). The i-STAT (R) showed a small bias compared to the LA Plus (TM) meter (-0.0227 +/- 0.4542 with 95% limits of agreement from -0.09129 to 0.8675). The LA Plus (TM) meter showed slightly higher values overall (0.0227 mmol/L), but the i-STAT (R) showed higher results at lactate levels above 2.5 mmol/L. Conclusions: The observed similarity in performance between the two devices suggests that both are capable of reliably measuring lactate levels in a trauma situation. The LA Plus (TM) meter provides fast results with only one drop of blood. This study supports the prehospital use of POC devices.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] New automated analysis to monitor neutrophil function point-of-care in the intensive care unit after trauma
    Lillian Hesselink
    Roy Spijkerman
    Emma de Fraiture
    Suzanne Bongers
    Karlijn J. P. Van Wessem
    Nienke Vrisekoop
    Leo Koenderman
    Luke P. H. Leenen
    Falco Hietbrink
    Intensive Care Medicine Experimental, 8
  • [42] New automated analysis to monitor neutrophil function point-of-care in the intensive care unit after trauma
    Hesselink, Lillian
    Spijkerman, Roy
    de Fraiture, Emma
    Bongers, Suzanne
    Van Wessem, Karlijn J. P.
    Vrisekoop, Nienke
    Koenderman, Leo
    Leenen, Luke P. H.
    Hietbrink, Falco
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2020, 8 (01)
  • [43] Prospective observational study of point-of-care ultrasound for diagnosing pneumonia
    Lissaman, Claire
    Kanjanauptom, Panida
    Ong, Cyril
    Tessaro, Mark
    Long, Elliot
    O'Brien, Adam
    ARCHIVES OF DISEASE IN CHILDHOOD, 2019, 104 (01) : 12 - 18
  • [44] Evaluation of point-of-care maternal venous lactate testing in normal pregnancy
    Maguire, Patrick J.
    Finlay, Janna
    Power, Karen A.
    Harley, Ruth
    Mhurchu, Muireann Ni
    Sheehan, Sharon R.
    Fanning, Rebecca A.
    Turner, Michael J.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2016, 29 (16): : 2607 - 2610
  • [45] Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
    Walther, Louise Houlberg
    Zegers, Floor
    Nybo, Mads
    Mogensen, Christian Backer
    Christensen, Erika Frischknecht
    Lassen, Annmarie Touborg
    Mikkelsen, Soren
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (06) : 1679 - 1687
  • [46] Point-of-Care Synovial Lactate to Distinguish Between Septic and Aseptic Arthritis
    Farshidpour, L.
    Tallman, Ives C.
    Shu, E.
    Darracq, M.
    Young, M.
    ANNALS OF EMERGENCY MEDICINE, 2018, 72 (04) : S73 - S73
  • [47] Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
    Louise Houlberg Walther
    Floor Zegers
    Mads Nybo
    Christian Backer Mogensen
    Erika Frischknecht Christensen
    Annmarie Touborg Lassen
    Søren Mikkelsen
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1679 - 1687
  • [48] Pediatric Malaria with Respiratory Distress: Prognostic Significance of Point-of-Care Lactate
    Mitran, Catherine
    Opoka, Robert O.
    Conroy, Andrea L.
    Namasopo, Sophie
    Kain, Kevin C.
    Hawkes, Michael T.
    MICROORGANISMS, 2023, 11 (04)
  • [49] Comparison of lactate values between point-of-care and central laboratory analyzers
    Karon, Brad S.
    Scott, Renee
    Burritt, Mary F.
    Santrach, Paula J.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2007, 128 (01) : 168 - 171
  • [50] Accuracy of prehospital point-of-care lactate in early in-hospital mortality
    Martin-Rodriguez, Francisco
    Lopez-Izquierdo, Raul
    Medina-Lozano, Elena
    Ortega Rabbione, Guillermo
    del Pozo Vegas, Carlos
    Carbajosa Rodriguez, Virginia
    Castro Villamor, Miguel Angel
    Sanchez-Soberon, Irene
    Sanz-Garcia, Ancor
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2020, 50 (12)