Observational Analysis of Point-of-Care Lactate Plus™ Meter in Preclinical Trauma Models

被引:0
|
作者
Gaeth, Catharina [1 ]
Duarte, Jamila [1 ]
Rodriguez, Alvaro [1 ]
Powers, Amber [1 ]
Stone II, Randolph [1 ]
机构
[1] United States Army Inst Surg Res, Combat Wound Care, 3698 Chambers Pass,JBSA Ft Sam Houston, Houston, TX 78234 USA
关键词
point of care; lactate; prehospital; preclinical trauma models; swine; whole blood; PREHOSPITAL SERUM LACTATE; SYSTOLIC BLOOD-PRESSURE; MORTALITY; ACCURACY; PREDICTOR; OUTCOMES;
D O I
10.3390/diagnostics14232641
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Blood lactate concentration is often used to assess systemic hypoperfusion, tissue hypoxia, and sepsis in trauma patients and serves as a prognostic indicator and marker of response to therapy. Point-of-care (POC) devices provide rapid lactate measurements with a single drop of blood. In this study, lactate values from whole blood, measured with two POC devices, Abbott i-STAT (R) and the Nova Biomedical Lactate (LA) Plus (TM) meter, are compared. Methods: An observational analysis of 760 blood samples from four preclinical trauma animal models was performed. Lactate was measured simultaneously with two POC devices (i-STAT (R) and the Lactate Plus (TM) meter). The evaluation in the form of a Bland-Altman diagram showed the agreement of the tests. Results: The Spearman correlation was 0.9180 (95% CI 0.9056 to 0.9288) for i-STAT (R) vs. the LA Plus (TM) meter. Both tests showed a significant increase in lactate after injury (p < 0.05). The i-STAT (R) showed a small bias compared to the LA Plus (TM) meter (-0.0227 +/- 0.4542 with 95% limits of agreement from -0.09129 to 0.8675). The LA Plus (TM) meter showed slightly higher values overall (0.0227 mmol/L), but the i-STAT (R) showed higher results at lactate levels above 2.5 mmol/L. Conclusions: The observed similarity in performance between the two devices suggests that both are capable of reliably measuring lactate levels in a trauma situation. The LA Plus (TM) meter provides fast results with only one drop of blood. This study supports the prehospital use of POC devices.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Prehospital point-of-care lactate following trauma: A systematic review
    Lewis, Christopher T.
    Naumann, David N.
    Crombie, Nick
    Midwinter, Mark J.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2016, 81 (04): : 748 - 755
  • [2] Lactate and point-of-care testing
    Mizock, BA
    CRITICAL CARE MEDICINE, 1998, 26 (09) : 1474 - 1476
  • [3] EVALUATION OF SERIAL BLOOD LACTATE AND THE USE OF A POINT-OF-CARE LACTATE METER IN LIVE-STRANDED PINNIPEDS
    Marinkovich, Matt
    Wack, Raymund F.
    Field, Cara L.
    Whoriskey, Sophie T.
    Kass, Philip H.
    Gjeltema, Jenessa
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2019, 50 (01) : 137 - 146
  • [4] Point-of-Care Ultrasound in Trauma
    Gleeson, Timothy
    Blehar, David
    SEMINARS IN ULTRASOUND CT AND MRI, 2018, 39 (04) : 374 - 383
  • [5] Agreement of point-of-care and laboratory lactate levels among trauma patients and association with transfusion
    Mitra, Biswadev
    Essery, Madison
    Somesh, Abha
    Talarico, Carly
    Olaussen, Alexander
    Anderson, David
    Meadley, Benjamin
    VOX SANGUINIS, 2025, 120 (02) : 188 - 192
  • [6] Point-of-Care Ultrasound for the Trauma Anesthesiologist
    Heinz, Eric R.
    Vincent, Anita
    CURRENT ANESTHESIOLOGY REPORTS, 2022, 12 (02) : 217 - 225
  • [7] Point-of-Care Thoracic Ultrasound in Trauma
    Cook, Justin O.
    CURRENT RESPIRATORY MEDICINE REVIEWS, 2015, 11 (01) : 8 - 16
  • [8] Point-of-care detection of lactate in cerebrospinal fluid
    Stephani, C.
    Choi, A. H. K.
    Moerer, O.
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2021, 9 (01)
  • [9] Point-of-care detection of lactate in cerebrospinal fluid
    C. Stephani
    A. H. K. Choi
    O. Moerer
    Intensive Care Medicine Experimental, 9
  • [10] Point-of-Care Ultrasound for the Trauma Anesthesiologist
    Eric R. Heinz
    Anita Vincent
    Current Anesthesiology Reports, 2022, 12 : 217 - 225