Accuracy of a Novel High-Throughput "Car Blood Pressure" Measurement Protocol
被引:1
|
作者:
Lima, Neiberg de Alcantara
论文数: 0引用数: 0
h-index: 0
机构:
Wayne State Univ, Dept Internal Med, Div Cardiovasc Dis, Detroit, MI 48202 USA
Hartford Hosp, Hartford HealthCare Heart & Vasc Inst, Hartford, CT 06106 USAWayne State Univ, Dept Internal Med, Div Cardiovasc Dis, Detroit, MI 48202 USA
Lima, Neiberg de Alcantara
[1
,2
]
论文数: 引用数:
h-index:
机构:
Cardozo, Shaun
[1
]
Johnson, Andrew
论文数: 0引用数: 0
h-index: 0
机构:
Wayne State Univ, Integrated Biosci Ctr, Detroit, MI USAWayne State Univ, Dept Internal Med, Div Cardiovasc Dis, Detroit, MI 48202 USA
Johnson, Andrew
[3
]
Reed, Brian
论文数: 0引用数: 0
h-index: 0
机构:
Wayne State Univ, Integrated Biosci Ctr, Detroit, MI USAWayne State Univ, Dept Internal Med, Div Cardiovasc Dis, Detroit, MI 48202 USA
Reed, Brian
[3
]
Korzeniewski, Steven
论文数: 0引用数: 0
h-index: 0
机构:
Wayne State Univ, Integrated Biosci Ctr, Detroit, MI USA
Wayne State Univ, Dept Emergency Med, Detroit, MI USAWayne State Univ, Dept Internal Med, Div Cardiovasc Dis, Detroit, MI 48202 USA
Korzeniewski, Steven
[3
,4
]
Levy, Phillip D.
论文数: 0引用数: 0
h-index: 0
机构:
Wayne State Univ, Integrated Biosci Ctr, Detroit, MI USA
Wayne State Univ, Dept Emergency Med, Detroit, MI USAWayne State Univ, Dept Internal Med, Div Cardiovasc Dis, Detroit, MI 48202 USA
Levy, Phillip D.
[3
,4
]
Brook, Robert D.
论文数: 0引用数: 0
h-index: 0
机构:
Wayne State Univ, Dept Internal Med, Div Cardiovasc Dis, Detroit, MI 48202 USAWayne State Univ, Dept Internal Med, Div Cardiovasc Dis, Detroit, MI 48202 USA
Brook, Robert D.
[1
]
机构:
[1] Wayne State Univ, Dept Internal Med, Div Cardiovasc Dis, Detroit, MI 48202 USA
blood pressure measurement;
hypertension;
public health;
screening;
D O I:
10.1093/ajh/hpaf016
中图分类号:
R6 [外科学];
学科分类号:
1002 ;
100210 ;
摘要:
Background More than one in three adults with hypertension in the United States are unaware of their condition, highlighting the importance of large-scale screening campaigns. Currently, the identification of hypertension is largely limited to medical settings. To help overcome this barrier, we developed a novel high-throughput screening protocol that measures blood pressure (BP) while patients remain seated in an automobile ("car-BP"). The aim of this study was to provide an initial assessment of the accuracy of car-BP.Methods Three BP readings were determined in a clinic exam room before and after three BP readings were taken while patients were seated in a parked car outside (n = 100 participants). The same validated device model (Omron HEM-907XL) and BP measurement methods adhering to guidelines were used in both scenarios. The average of all 6 clinic readings was compared to the average of the 3 car-BP readings in each individual.Results Mean clinic and car-BP readings were 120.9 +/- 16.2/78.0 +/- 9.9 and 118.9 +/- 15.2/76.0 +/- 10.0 mm Hg, respectively. The paired mean and absolute mean differences in systolic BP levels between methods were -1.92 mm Hg (95% confidence interval (CI) -3.2 to -0.7 mm Hg) and 4.8 mm Hg (95%CI 3.8 to 5.6 mm Hg), respectively. A total of 85% of participants had both systolic and diastolic BP levels <= 10 mm Hg different between measurement scenarios (meeting the a priori determined study primary outcome).Conclusions Car-BP represents an innovative and accessible approach for potential large-scale hypertension screening campaigns.