Improved Detection Accuracy of Chronic Vertebral Compression Fractures by Integrating Height Loss Ratio and Deep Learning Approaches

被引:1
|
作者
Lee, Jemyoung [1 ,2 ]
Park, Heejun [3 ]
Yang, Zepa [3 ]
Woo, Ok Hee [3 ]
Kang, Woo Young [3 ]
Kim, Jong Hyo [1 ,2 ,4 ,5 ,6 ]
机构
[1] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Appl Bioengn, Seoul 08826, South Korea
[2] ClariPi Inc, ClariPi Res, Seoul 03088, South Korea
[3] Korea Univ, Dept Radiol, Guro Hosp, Seoul 08308, South Korea
[4] Seoul Natl Univ, Dept Radiol, Coll Med, Seoul 03080, South Korea
[5] Seoul Natl Univ Hosp, Dept Radiol, Seoul 03080, South Korea
[6] Adv Inst Convergence Technol, Ctr Med IT Convergence Technol Res, Suwon 16229, South Korea
关键词
vertebral compression fracture; height loss ratio; deep learning; spine; computed tomography;
D O I
10.3390/diagnostics14222477
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This study aims to assess the limitations of the height loss ratio (HLR) method and introduce a new approach that integrates a deep learning (DL) model to enhance vertebral compression fracture (VCF) detection performance. Methods: We conducted a retrospective study on 589 patients with chronic VCFs. We compared four different methods: HLR-only, DL-only, a combination of HLR and DL for positive VCF, and a combination of HLR and DL for negative VCF. The models were evaluated using dice similarity coefficient, sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC). Results: The combined method (HLR + DL, positive) demonstrated the best performance with an AUROC of 0.968, sensitivity (94.95%), and specificity (90.59%). The HLR-only and the HLR + DL (negative) also showed strong discriminatory power, with AUROCs of 0.948 and 0.947, respectively. The DL-only model achieved the highest specificity (95.92%) but exhibited lower sensitivity (82.83%). Conclusions: Our study highlights the limitations of the HLR method in detecting chronic VCFs and demonstrates the improved performance of combining HLR with DL models.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Deep learning application of vertebral compression fracture detection using mask R-CNN
    Paik, Seungyoon
    Park, Jiwon
    Hong, Jae Young
    Han, Sung Won
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [22] Deep learning-based automated high-accuracy location and identification of fresh vertebral compression fractures from spinal radiographs: a multicenter cohort study
    Zhang, Hao
    Xu, Ruixiang
    Guo, Xiang
    Zhou, Dan
    Xu, Tongshuai
    Zhong, Xin
    Kong, Meng
    Zhang, Zhimin
    Wang, Yan
    Ma, Xuexiao
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [23] Deep learning-based artificial intelligence model for classification of vertebral compression fractures: A multicenter diagnostic study
    Xu, Fan
    Xiong, Yuchao
    Ye, Guoxi
    Liang, Yingying
    Guo, Wei
    Deng, Qiuping
    Wu, Li
    Jia, Wuyi
    Wu, Dilang
    Chen, Song
    Liang, Zhiping
    Zeng, Xuwen
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [24] Differentiation of acute and chronic vertebral compression fractures using conventional CT based on deep transfer learning features and hand-crafted radiomics features
    Zhang, Jun
    Liu, Jiayi
    Liang, Zhipeng
    Xia, Liang
    Zhang, Weixiao
    Xing, Yanfen
    Zhang, Xueli
    Tang, Guangyu
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [25] Differentiation of acute and chronic vertebral compression fractures using conventional CT based on deep transfer learning features and hand-crafted radiomics features
    Jun Zhang
    Jiayi Liu
    Zhipeng Liang
    Liang Xia
    Weixiao Zhang
    Yanfen Xing
    Xueli Zhang
    Guangyu Tang
    BMC Musculoskeletal Disorders, 24
  • [26] Enhanced Detection Performance of Acute Vertebral Compression Fractures Using a Hybrid Deep Learning and Traditional Quantitative Measurement Approach: Beyond the Limitations of Genant Classification
    Lee, Jemyoung
    Kim, Minbeom
    Park, Heejun
    Yang, Zepa
    Woo, Ok Hee
    Kang, Woo Young
    Kim, Jong Hyo
    BIOENGINEERING-BASEL, 2025, 12 (01):
  • [27] Association between bone turnover markers, BMD and height loss of cemented vertebrae after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures
    Shangjin Lin
    Xiaoxi Cai
    Qun Cheng
    Cong Chen
    Xuhai Cao
    Fengjian Yang
    Yongqian Fan
    Journal of Orthopaedic Surgery and Research, 17
  • [28] Association between bone turnover markers, BMD and height loss of cemented vertebrae after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures
    Lin, Shangjin
    Cai, Xiaoxi
    Cheng, Qun
    Chen, Cong
    Cao, Xuhai
    Yang, Fengjian
    Fan, Yongqian
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [29] Diagnostic Accuracy and Failure Mode Analysis of a Deep Learning Algorithm for the Detection of Cervical Spine Fractures
    Voter, A. F.
    Larson, M. E.
    Garrett, J. W.
    Yu, J. -P. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (08) : 1550 - 1556
  • [30] Enhancing Smishing Detection: A Deep Learning Approach for Improved Accuracy and Reduced False Positives
    Mehmood, Muhammad Khalid
    Arshad, Humaira
    Alawida, Moatsum
    Mehmood, Abid
    IEEE ACCESS, 2024, 12 : 137176 - 137193