Functional MRI study with conductivity signal changes during visual stimulation

被引:1
|
作者
Kim, Hyug-Gi [1 ]
Yoon, Youngeun [2 ]
Lee, Mun Bae [3 ]
Jeong, Jeongin [2 ]
Lee, Jiyoon [2 ]
Kwon, Oh In [3 ]
Jahng, Geon-Ho [4 ]
机构
[1] Kyung Hee Univ Hosp, Dept Radiol, Seoul, South Korea
[2] Kyung Hee Univ, Coll Elect & Informat, Undergraduate Sch, Dept Biomed Engn, Yongin, Gyeonggi Do, South Korea
[3] Konkuk Univ, Coll Basic Sci, Dept Math, Seoul, South Korea
[4] Kyung Hee Univ, Kyung Hee Univ Hosp Gangdong, Dept Radiol, Coll Med, 892 Dongnam Ro, Seoul 05278, South Korea
基金
新加坡国家研究基金会;
关键词
Functional MRI; Conductivity signal; MREPT; Visual stimulation; Cerebrospinal fluid (CSF); ELECTRICAL-IMPEDANCE TOMOGRAPHY; HUMAN BRAIN; TISSUE; ACTIVATION; CURRENTS; FIELDS; MODEL;
D O I
10.1016/j.jneumeth.2024.110288
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Although blood oxygen level-dependent (BOLD) functional MRI (fMRI) is a standard method, major BOLD signals primarily originate from intravascular sources. Magnetic resonance electrical properties tomography (MREPT)-based fMRI signals may provide additional insights into electrical activity caused by alterations in ion concentrations and mobilities. Purpose: This study aimed to investigate the neuronal response of conductivity during visual stimulation and compare it with BOLD. Materials and methods: A total of 30 young, healthy volunteers participated in two independent experiments using BOLD and MREPT techniques with a visual stimulation paradigm at 3 T MRI. The first set of MREPT fMRI data was obtained using a multi-echo spin-echo (SE) echo planar imaging (EPI) sequence from 14 participants. The second set of MREPT fMRI data was collected from 16 participants using both a single-echo SE-EPI and a singleecho three-dimensional (3D) balanced fast-field-echo (bFFE) sequence. We reconstructed the time-course Larmor frequency conductivity to evaluate hemodynamics. Results: Conductivity values slightly increased during visual stimulation. Activation strengths were consistently stronger with BOLD than with conductivity for both SE-EPI MREPT and bFFE MREPT. Additionally, the activated areas were always larger with BOLD than MREPT. Some participants also exhibited decreased conductivity values during visual stimulations. In Experiment 1, conductivity showed significant differences between the fixation and visual stimulation blocks in the secondary visual cortex (SVC) and cuneus, with conductivity differences of 0.43 % and 0.47 %, respectively. No significant differences in conductivity were found in the cerebrospinal fluid (CSF) areas between the two blocks. In Experiment 2, significant conductivity differences were observed between the two blocks in the SVC, cuneus, and lingual gyrus for SE-EPI MREPT, with differences of 0.90 %, 0.67%, and 0.24 %, respectively. Again, no significant differences were found in the CSF areas. Conclusion: Conductivity values increased slightly during visual stimulation in the visual cortex areas but were much weaker than BOLD responses. The conductivity change during visual stimulation was less than 1 % compared to the fixation block. No significant differences in conductivity were observed between the primary visual cortex (PVC)-CSF and SVC-CSF during fixation and visual stimulations, suggesting that the observed conductivity changes may not be related to CSF changes in the visual cortex but rather to diffusion changes. Future research should explore the potential of MREPT to detect neuronal electrical activity and hemodynamic changes, with further optimization of the MREPT technique.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Variation of functional MRI signal in response to frequency of somatosensory stimulation in α-chloralose anesthetized rats
    Max-Planck-Inst. F. Neurologische F., Abt. F. Experimentelle Neurologie, Köln, Germany
    不详
    MAGN. RESON. MED., 1 (13-15):
  • [42] Simultaneous detection of metabolite concentration changes, water BOLD signal and pH changes during visual stimulation in the human brain at 9.4T
    Dorst, Johanna
    Borbath, Tamas
    Landheer, Karl
    Avdievich, Nikolai
    Henning, Anke
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2022, 42 (06): : 1104 - 1119
  • [43] A functional MRI study of somatotopic representation of somatosensory stimulation in the cerebellum
    M. Takanashi
    K. Abe
    T. Yanagihara
    S. Sakoda
    H. Tanaka
    N. Hirabuki
    H. Nakamura
    N. Fujita
    Neuroradiology, 2003, 45 : 149 - 152
  • [44] A functional MRI study of somatotopic representation of somatosensory stimulation in the cerebellum
    Takanashi, M
    Abe, K
    Yanagihara, T
    Sakoda, S
    Tanaka, H
    Hirabuki, N
    Nakamura, H
    Fujita, N
    NEURORADIOLOGY, 2003, 45 (03) : 149 - 152
  • [45] The effects of anaesthesia on cortical stimulation in rats: A functional MRI study
    Dashti M.
    Geso M.
    Williams J.
    Australasian Physics & Engineering Sciences in Medicine, 2005, 28 (1): : 21 - 25
  • [46] Functional MRI during sleep:: BOLD signal decreases and their electrophysiological correlates
    Czisch, M
    Wehrle, R
    Kaufmann, C
    Wetter, TC
    Holsboer, F
    Pollmächer, T
    Auer, DP
    EUROPEAN JOURNAL OF NEUROSCIENCE, 2004, 20 (02) : 566 - 574
  • [47] Visual memory and functional MRI
    Angioi-Duprez, K
    Braun, M
    Jonveaux, T
    Picard, L
    George, JL
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2000, 23 (01): : 19 - 26
  • [48] Development of a new binocular visual stimulation device using image guides for functional MRI
    Nishida, Y
    Hayashi, O
    Iwami, T
    Kimura, M
    Kani, K
    Ito, R
    NEURO-OPHTHALMOLOGY, 2000, 24 (02) : 343 - 348
  • [49] Comparison of auditory and visual stimulation functional MRI paradigms for language lateralization in pediatric patients
    Strawsburg, RH
    Byars, A
    Holland, SK
    Schmidhorst, V
    Dunn, S
    Ball, W
    NEUROLOGY, 2002, 58 (07) : A152 - A152
  • [50] False-positive analysis of functional MRI during simulated deep brain stimulation: A phantom study
    Liu, Ho-Ling
    Chen, Hsin-Mei
    Wu, Yu-Chien
    Lim, Siew-Na
    Huang, Chih-Mao
    Hsu, Yuan-Yu
    Wai, Yau-Yau
    Wu, Tony
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1439 - 1442