Optimizing data center energy consumption via energy complementarity scheduling

被引:0
|
作者
Liu, Xuehui [1 ]
Hou, Guisheng [1 ]
Yang, Lei [1 ]
机构
[1] Shandong Univ Sci & Technol, Coll Econ & Management, Qingdao, Peoples R China
关键词
Data center; Multi-energy interaction; Multi-objective optimization; NSGA-III algorithm; OPTIMIZATION; ALGORITHM;
D O I
10.1016/j.egyr.2024.11.032
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Considering the degree of flexible energy supply and demand matching, four types of energy sources were combined and a dynamic multi-energy combination optimization scheduling model was established for data centers to realize the optimal scheduling of multiple energy sources to meet the minimum overall energy consumption of data centers. Model construction and simulation analysis were used to conduct the research. To maximize the use of wind power and photovoltaic renewable energy, a multi-objective optimization scheduling model was constructed with the objectives of maximum flexibility of supply and demand matching in a single day, minimum penalty for predicted photovoltaic power consumption, minimum average service time of data centers, and minimum overall energy consumption of data centers. The NSGA-III framework was used to solve the constructed model. The results showed that even in areas rich in renewable energy, because of the limited power of renewable energy generation, the purchase of electric energy and natural gas as the main energy source remained necessary to ensure the stable operation of data centers. Data centers can use the complementarity of photovoltaic and wind power generation times to achieve basic complementarity of power generation. In terms of cooling energy consumption, natural gas waste heat-driven absorption refrigerator output accounted for a significant proportion, approximately twice that of the electric refrigerator and could effectively reduce the energy consumption of electric refrigeration. The simulation results of energy scheduling model show that it is necessary to increase the proportion of natural gas and green energy in data center energy supply, maximize the use of renewable energy such as wind power and photovoltaic power generation, give full play to the characteristics of wind power and photovoltaic power generation time complementarity, and build a green energy complementary data center energy supply mode.
引用
收藏
页码:5990 / 5997
页数:8
相关论文
共 50 条
  • [31] Modeling on Energy Consumption of Cloud Computing Based on Data Center
    Yang, Yu
    Wei, Jiang
    Wei, Guan
    Ping, Li
    Zhou Yongmin
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLIED SCIENCE AND ENGINEERING INNOVATION, 2015, 12 : 594 - 601
  • [32] A Generic Simulation Framework for Energy Consumption in Data Center Networks
    Zhao, Chang
    Ge, Bowen
    Tian, Xiaohua
    2013 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS (ICC), 2013, : 1678 - 1682
  • [33] Research and practice of energy saving and consumption reducing in Data center
    Yue, Yu
    Cao, Kejian
    Shen, Bin
    Cao, Yuan
    Zhang, Dakun
    PROCEEDINGS OF THE 2015 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER ENGINEERING AND ELECTRONICS (ICECEE 2015), 2015, 24 : 404 - 409
  • [34] On energy consumption of switch-centric data center networks
    Popoola, Olusogo
    Pranggono, Bernardi
    JOURNAL OF SUPERCOMPUTING, 2018, 74 (01): : 334 - 369
  • [36] On energy consumption of switch-centric data center networks
    Olusogo Popoola
    Bernardi Pranggono
    The Journal of Supercomputing, 2018, 74 : 334 - 369
  • [37] Regression Cloud Models and Their Applications in Energy Consumption of Data Center
    Zhou, Yanshuang
    Li, Na
    Li, Hong
    Zhang, Yongqiang
    JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING, 2015, 2015 (2015)
  • [38] Data center service pricing strategies for energy consumption optimization
    Yu, Xiao
    Wu, Jianzhang
    Wang, Wei
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2012, 42 (06): : 1080 - 1084
  • [39] Optimization on air distribution and energy consumption of a small data center
    Zhang, Jie
    Zhou, Hao
    Feng, Zhuangbo
    Sun, Chao
    Jin, Zhou
    Long, Zhengwei
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2014, 47 (07): : 647 - 652
  • [40] Investigation into the energy consumption of a data center with a thermosyphon heat exchanger
    Zhou Feng
    Tian Xin
    Ma GuoYuan
    CHINESE SCIENCE BULLETIN, 2011, 56 (20): : 2185 - 2190