TUBE PLUGGING INDUCED TEMPERATURE NON-UNIFORMITY IN ONCE THROUGH STEAM GENERATOR

被引:0
|
作者
Luo, Yunhao [1 ]
Xie, Xiaoyang [1 ]
Li, Xiaowei [1 ]
Wu, Xinxin [1 ]
机构
[1] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
temperature non-uniformity; porous media; thermal-hydraulics code; HTR-PM;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Multi-layered helically coiled tube bundles are used as heat-transfer area of High Temperature Gas-cooled Reactor-Pebble Module (HTR-PM) Once Through Steam Generators (OTSGs). Tube plugging is very common in Pressurized Water Reactor (PWR) steam generators. Though the corrosion in HTGR OTSG is not so severe as that in PWR SG, it has large possibility to plug tube. However, plugged tubes will lead to temperature non-uniformity in the shell side helium in the steam generator. Large temperature non-uniformity will raise the tube working temperature. Excessive temperature non-uniformity will also lead to high thermal stress of the tube sheet. Thus, a precise prediction of temperature distribution after tube plugging is essential for the safety and efficiency of HTGR OTSG. An in-house code for tube and shell side coupled thermal analysis of HTGR SG was developed based on porous media assumption. This code is used to simulate the tube and shell side temperature distributions after plugging 1 or 2 tubes. The effect of molecular diffusion, turbulent diffusion and the dispersion are considered using the effective thermal diffusivity, which is normalized as the Peclet number (Pe). However, Pe of cross flow over tube bundles varies a lot in previous investigations. Thus, in the current investigation, a large range of Peclet number values are used for simulation. When Pe increases, outlet steam temperature non-uniformity become more severe. Numerical simulation shows that plugging one tube of inner layer will lead to more severe temperature non-uniformity than that of outer layers. The temperature non-uniformity will become obvious when the number of plugged tube increases. The code is validated using experiments carried out on the Engineering Test Facility for Steam Generator (ETF-SG) of HTR-PM. Experiments were performed for cases with 1 or 2 tubes plugged. Comparison shows that the present code can predict the experimental measurements well.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Simulation analysis of static and dynamic characteristics of once-through steam generator in concentric annuli tube
    Wei Zhang
    Xin-qian Bian
    Guo-qing Xia
    Journal of Marine Science and Application, 2006, 5 (3) : 36 - 40
  • [42] Temperature non-uniformity detection on dPCR chips and temperature sensor calibration
    Ganova, Martina
    Wang, Xinlu
    Yan, Zhiqiang
    Zhang, Haoqing
    Lednicky, Tomas
    Korabecna, Marie
    Neuzil, Pavel
    RSC ADVANCES, 2022, 12 (04) : 2375 - 2382
  • [43] Experiment and verification test of the once-through steam generator of the 10 MW High-temperature Gas-Cooled Reactor flow stability of the once-through steam generator
    Ju, HM
    Yu, Y
    Huang, ZY
    Zhang, YJ
    Liu, ZY
    Li, J
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2004, 41 (04) : 524 - 528
  • [44] Develoment of plugging criterion of steam generator tube based on coalescence model of collinear axial through-wall cracks
    Lee, J.H.
    Park, Y.W.
    Song, M.H.
    Kim, Y.J.
    Moon, S.I.
    2000, American Society of Mechanical Engineers (409):
  • [45] ANALYSIS OF STEAM GENERATOR TUBE PLUGGING IN A PWR. INFLUENCE IN THE EMERGENCY OPERATING PROCEDURES
    Pla, Patricia
    Reventos, Francesc
    Martin Ramos, Manuel
    Sol, Ismael
    22ND INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE, (NENE 2013), 2013,
  • [46] MANAGEMENT OF PWR STEAM GENERATOR TUBE PLUGGING AND PRIMARY FLOW-RATE PREDICTIONS
    Brunin, Olivier
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE (PVP-2011), VOL 7, 2012, : 193 - 200
  • [47] Dean instability of nanofluids with radial temperature and concentration non-uniformity
    Avramenko, A. A.
    Tyrinov, A. I.
    Shevchuk, I. V.
    Dmitrenko, N. P.
    PHYSICS OF FLUIDS, 2016, 28 (03)
  • [48] Local wafer temperature non-uniformity correction with laser irradiation
    Rao, Preetham P.
    2015 26TH ANNUAL SEMI ADVANCED SEMICONDUCTOR MANUFACTURING CONFERENCE (ASMC), 2015, : 179 - 184
  • [49] Experimental investigation of surface temperature non-uniformity in spray cooling
    Zhao, Xiao
    Yin, Zhichao
    Zhang, Bo
    Yang, Zhuqiang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 146
  • [50] Temperature Dependence of Non-uniformity in Energy of Systems with Holonomic Constraints
    Konishi, Tetsuro
    Yanagita, Tatsuo
    JOURNAL OF STATISTICAL PHYSICS, 2023, 190 (01)