Solar background radiation temperature calibration of a pure rotational Raman lidar

被引:0
|
作者
Jayaweera, Vasura [1 ]
Sica, Robert J. [1 ]
Martucci, Giovanni [2 ]
Haefele, Alexander [1 ,2 ]
机构
[1] Univ Western Ontario, Dept Phys & Astron, London, ON N6A 3K7, Canada
[2] MeteoSwiss, Fed Off Meteorol & Climatol, CH-1530 Payerne, Switzerland
基金
加拿大自然科学与工程研究理事会;
关键词
METEOROLOGICAL OBSERVATIONS; VAISALA RS92; RETRIEVAL; RALMO; RADIOSONDES; VALIDATION; GRUAN; RS41;
D O I
10.5194/amt-18-1461-2025
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Raman lidars are an important tool for measuring important atmospheric parameters including water vapour content and temperature in the troposphere and stratosphere. These measurements enable climatology studies and trend analyses to be performed. To detect long-term trends it is critical that the calibration of the system and the monitoring of its associated uncertainties are as reliable and continuous as possible. Here we demonstrate a new methodology to derive calibration coefficients for a rotational Raman temperature lidar. We use solar background measurements taken by the rotational Raman channels of the Raman Lidar for Meteorological Observations (RALMO) located at the Federal Office of Meteorology and Climatology (MeteoSwiss) in Payerne, Switzerland, to calculate a relative calibration as a function of time, which is made an absolute calibration by requiring only a single external calibration, in our case with an ensemble of radiosonde flights. This approach was verified using an external time series of coincident radiosonde measurements. We employed the calibration technique on historical measurements that used a Licel data acquisition system and established a calibration time series spanning 2011 to 2015 using both the radiosonde-based external and solar-background-based internal methods. Our results show that using the background calibration technique reduces the mean bias of the calibration by an average of 0.5 K across the troposphere compared to using the local radiosoundings. Furthermore, it demonstrates the background calibration's ability to adjust and maintain continuous calibration values even amidst sudden changes in the system, which sporadic external calibration could miss. This approach ensures that climatological averages and trends remain unaffected by the drift effects commonly associated with using daily operational radiosondes. It also allows a lidar not co-located with a routine external source to be continuously calibrated once an initial external calibration is done. Furthermore, the technique works for temperature retrievals using both the optimal estimation method and the traditional temperature algorithms.
引用
收藏
页码:1461 / 1469
页数:9
相关论文
共 50 条
  • [31] Saturation correction near the ground for pure rotational Raman lidar
    Wang, Zhongkun
    Zhang, Yinchao
    Chen, He
    Chen, Siying
    Guo, Pan
    OPTICAL ENGINEERING, 2015, 54 (01)
  • [32] Collision broadening effect upon tropospheric temperature calibration functions for pure rotational Raman lidars
    Gerasimov, V. V.
    Zuev, V. V.
    Pravdin, V. L.
    Nakhtigalova, D. P.
    Pavlinskiy, A. V.
    21ST INTERNATIONAL SYMPOSIUM ON ATMOSPHERIC AND OCEAN OPTICS: ATMOSPHERIC PHYSICS, 2015, 9680
  • [33] Rotational Raman Lidar measurements of atmospheric temperature in the UV
    Di Girolamo, P
    Marchese, R
    Whiteman, DN
    Demoz, BB
    GEOPHYSICAL RESEARCH LETTERS, 2004, 31 (01) : L011061 - 5
  • [34] Cloud temperature measurement using rotational Raman lidar
    Su, Jia
    McCormick, M. Patrick
    Wu, Yonghua
    Lee, Robert B., III
    Lei, Liqiao
    Liu, Zhaoyan
    Leavor, Kevin R.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2013, 125 : 45 - 50
  • [35] Multichannel Pure Rotational Raman Spectroscopic System for Absolute-Probing Temperature Lidar Throughout a Day
    Li Shichin
    Wang Xu
    Zhang Penghui
    Xin Wenhui
    Hua DengXin
    Hu Xianglong
    Song Yuehui
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2022, 49 (13):
  • [36] Airborne compact rotational Raman lidar for temperature measurement
    Wu, Decheng
    Wang, Zhien
    Wechsler, Perry
    Mahon, Nick
    Deng, Min
    Glover, Brent
    Burkhart, Matthew
    Kuestner, William
    Heesen, Ben
    OPTICS EXPRESS, 2016, 24 (18): : A1210 - A1223
  • [37] Accurate inversion of tropospheric bottom temperature using pure rotational Raman lidar in polluted air condition
    He, Jingxi
    Chen, Siying
    Zhang, Yinchao
    Guo, Pan
    Chen, He
    OPTICS COMMUNICATIONS, 2019, 452 : 88 - 94
  • [38] Single-line-extracted pure rotational Raman lidar to measure atmospheric temperature and aerosol profiles
    Weng, Miao
    Yi, Fan
    Liu, Fuchao
    Zhang, Yunpeng
    Pan, Xiangliang
    OPTICS EXPRESS, 2018, 26 (21): : 27555 - 27571
  • [39] The Double Grating Monochromator's Design for Pure Rotational Raman lidar
    Ge Xian-ying
    Chen He
    Zhang Yin-chao
    Chen Si-ying
    Guo Pan
    Mu Tao-tao
    Bu Zhi-chao
    Yang Jian
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: LASER SENSING AND IMAGING AND APPLICATIONS, 2013, 8905
  • [40] A simulation comparison of calibration functions for different sets of spectral filter passbands in the traditional pure rotational Raman lidar technique
    Gerasimov, Vladislav V.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2020, 126 (11):