Solar background radiation temperature calibration of a pure rotational Raman lidar

被引:0
|
作者
Jayaweera, Vasura [1 ]
Sica, Robert J. [1 ]
Martucci, Giovanni [2 ]
Haefele, Alexander [1 ,2 ]
机构
[1] Univ Western Ontario, Dept Phys & Astron, London, ON N6A 3K7, Canada
[2] MeteoSwiss, Fed Off Meteorol & Climatol, CH-1530 Payerne, Switzerland
基金
加拿大自然科学与工程研究理事会;
关键词
METEOROLOGICAL OBSERVATIONS; VAISALA RS92; RETRIEVAL; RALMO; RADIOSONDES; VALIDATION; GRUAN; RS41;
D O I
10.5194/amt-18-1461-2025
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Raman lidars are an important tool for measuring important atmospheric parameters including water vapour content and temperature in the troposphere and stratosphere. These measurements enable climatology studies and trend analyses to be performed. To detect long-term trends it is critical that the calibration of the system and the monitoring of its associated uncertainties are as reliable and continuous as possible. Here we demonstrate a new methodology to derive calibration coefficients for a rotational Raman temperature lidar. We use solar background measurements taken by the rotational Raman channels of the Raman Lidar for Meteorological Observations (RALMO) located at the Federal Office of Meteorology and Climatology (MeteoSwiss) in Payerne, Switzerland, to calculate a relative calibration as a function of time, which is made an absolute calibration by requiring only a single external calibration, in our case with an ensemble of radiosonde flights. This approach was verified using an external time series of coincident radiosonde measurements. We employed the calibration technique on historical measurements that used a Licel data acquisition system and established a calibration time series spanning 2011 to 2015 using both the radiosonde-based external and solar-background-based internal methods. Our results show that using the background calibration technique reduces the mean bias of the calibration by an average of 0.5 K across the troposphere compared to using the local radiosoundings. Furthermore, it demonstrates the background calibration's ability to adjust and maintain continuous calibration values even amidst sudden changes in the system, which sporadic external calibration could miss. This approach ensures that climatological averages and trends remain unaffected by the drift effects commonly associated with using daily operational radiosondes. It also allows a lidar not co-located with a routine external source to be continuously calibrated once an initial external calibration is done. Furthermore, the technique works for temperature retrievals using both the optimal estimation method and the traditional temperature algorithms.
引用
收藏
页码:1461 / 1469
页数:9
相关论文
共 50 条
  • [1] A Novel Calibration Method for Pure Rotational Raman Lidar Temperature Profiling
    He, Jingxi
    Chen, Siying
    Zhang, Yinchao
    Guo, Pan
    Chen, He
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2018, 123 (19) : 10925 - 10934
  • [2] Robust calibration method for pure rotational Raman lidar temperature measurement
    Chen, Hao
    Chen, Siying
    Zhang, Yinchao
    Guo, Pan
    Chen, He
    Chen, Binglong
    OPTICS EXPRESS, 2015, 23 (16): : 21232 - 21242
  • [3] Analytical calibration functions for the pure rotational Raman lidar technique
    Gerasimov, Vladislav V.
    Zuev, Vladimir V.
    OPTICS EXPRESS, 2016, 24 (05): : 5136 - 5151
  • [4] Pure rotational Raman lidar for atmospheric temperature measurements
    Kim, DY
    Cha, HK
    Lee, JM
    Bobronikov, S
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2001, 39 (05) : 838 - 841
  • [5] Tropospheric temperature measurements with the pure rotational Raman lidar technique using nonlinear calibration functions
    Zuev, Vladimir V.
    Gerasimov, Vladislav V.
    Pravdin, Vladimir L.
    Pavlinskiy, Aleksei V.
    Nakhtigalova, Daria P.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2017, 10 (01) : 315 - 332
  • [6] Comparative analysis of calibration functions in the pure rotational Raman lidar technique
    Vladislav V. Gerasimov
    Applied Physics B, 2018, 124
  • [7] Comparative analysis of calibration functions in the pure rotational Raman lidar technique
    Gerasimov, Vladislav V.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2018, 124 (07):
  • [8] Pure rotational Raman lidar for absolute detection of atmospheric temperature
    Li Shi-Chun
    Wang Da-Long
    Li Qi-Meng
    Song Yue-Hui
    Liu Li-Juan
    Hua Deng-Xin
    ACTA PHYSICA SINICA, 2016, 65 (14)
  • [9] Temperature measurement error simulation of the pure rotational Raman lidar
    Jia, Jingyu
    Huang, Yong
    Wang, Zhirui
    Yi, Fan
    Shen, Jianglin
    Jia, Xiaoxing
    Chen, Huabin
    Yang, Chuan
    Zhang, Mingyang
    SELECTED PAPERS OF THE PHOTOELECTRONIC TECHNOLOGY COMMITTEE CONFERENCES, 2015, 9795
  • [10] Temporal stability of calibration functions in the traditional pure rotational Raman lidar technique
    Gerasimov, Vladislav V.
    OSA CONTINUUM, 2021, 4 (02) : 299 - 314