A Pragmatic Approach to Handling Censored Data Below the Lower Limit of Quantification in Pharmacokinetic Modeling

被引:0
|
作者
Wijk, Marie [1 ]
Wasmann, Roeland E. [1 ]
Jacobson, Karen R. [2 ,3 ]
Svensson, Elin M. [4 ,5 ]
Denti, Paolo [1 ]
机构
[1] Univ Cape Town, Dept Med, Div Clin Pharmacol, Cape Town, South Africa
[2] Boston Univ, Sch Med, Sect Infect Dis, Boston, MA USA
[3] Boston Med Ctr, Boston, MA USA
[4] Uppsala Univ, Dept Pharm, Uppsala, Sweden
[5] Radboud Univ Nijmegen, Med Ctr, Dept Pharm, Nijmegen, Netherlands
关键词
censoring; likelihood; NONMEM; parameter estimation; population pharmacokinetics; IMPACT; REPLACEMENT; NONMEM;
D O I
10.1002/psp4.70015
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Proper handling of data below the lower limit of quantification (BLQ) is crucial for accurate pharmacokinetic parameter estimation. The M3 method proposed by Beal uses a likelihood-based approach that is precise but has been reported to suffer from numerical issues in converging. Common alternatives include ignoring the BLQs (M1), imputing half of the lower limit of quantification and ignoring trailing BLQs (M6) or imputing zero (M7). The imputation methods fail to account for the additional uncertainty affecting imputed observations. We used NONMEM with FOCE-I/Laplace to compare the stability, bias, and precision of methods M1, M3, M6, M7, and modified versions M6+ and M7+ that inflate the additive residual error for BLQs. Real and simulated datasets with a two-compartment model were used to assess stability through parallel retries with perturbed initial estimates. The resulting differences in objective function values (OFV) were compared. Bias and precision were evaluated on simulated data using stochastic simulations and estimations. M3 yielded different OFV across retries (+/- 14.7), though the parameter estimates were similar. All other methods, except M7 (+/- 130), were stable. M3 demonstrated the best bias and precision (average rRMSE 18.7%), but M6+ and M7+ performed comparably (26.0% and 23.3%, respectively). The unstable OFV produced by M3 represents a challenge when used to guide model development. Imputation methods showed superior stability, and including inflated additive error improved bias and precision to levels comparable with M3. For these reasons, M7+ (of simpler implementation than M6+) is an attractive alternative to M3, especially during model development.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A Bayesian approach for estimating hexabromocyclododecane (HBCD) diastereomer compositions in water using data below limit of quantification
    Makiko Ichihara
    Atsushi Yamamoto
    Naoya Kakutani
    Miki Sudo
    Koh-ichi Takakura
    Environmental Science and Pollution Research, 2017, 24 : 2667 - 2674
  • [22] Likelihood based approaches to handling data below the quantification limit using NONMEM VI (vol 35, pg 401, 2008)
    Ahn, Jae Eun
    Karlsson, Mats O.
    Dunne, Adrian
    Ludden, Thomas M.
    JOURNAL OF PHARMACOKINETICS AND PHARMACODYNAMICS, 2010, 37 (03) : 305 - 308
  • [23] Ways to fit a PK model with some data below the quantification limit
    Beal, SL
    JOURNAL OF PHARMACOKINETICS AND PHARMACODYNAMICS, 2001, 28 (05) : 481 - 504
  • [24] Ways to Fit a PK Model with Some Data Below the Quantification Limit
    Stuart L. Beal
    Journal of Pharmacokinetics and Pharmacodynamics, 2001, 28 : 481 - 504
  • [25] Analysis of Toxicokinetic Data Using NONMEM: Impact of Quantification Limit and Replacement Strategies for Censored Data
    Jeremy P. Hing
    Steven G. Woolfrey
    Dennis Greenslade
    Peter M. C. Wright
    Journal of Pharmacokinetics and Pharmacodynamics, 2001, 28 : 465 - 479
  • [26] Analysis of toxicokinetic data using NONMEM: Impact of quantification limit and replacement strategies for censored data
    Hing, JP
    Woolfrey, SG
    Greenslade, D
    Wright, PMC
    JOURNAL OF PHARMACOKINETICS AND PHARMACODYNAMICS, 2001, 28 (05) : 465 - 479
  • [27] Impact of censoring data below an arbitrary quantification limit on structural model misspecification
    Byon, Wonkyung
    Fletcher, Courtney V.
    Brundage, Richard C.
    JOURNAL OF PHARMACOKINETICS AND PHARMACODYNAMICS, 2008, 35 (01) : 101 - 116
  • [28] Impact of censoring data below an arbitrary quantification limit on structural model misspecification
    Wonkyung Byon
    Courtney V. Fletcher
    Richard C. Brundage
    Journal of Pharmacokinetics and Pharmacodynamics, 2008, 35 : 101 - 116
  • [29] Comparison of Model Based and Model Independent Approaches for Handling Data Below the Limit of Quantitation
    Goti, V.
    Burns, R.
    Chaturvedula, A.
    Ette, E.
    JOURNAL OF PHARMACOKINETICS AND PHARMACODYNAMICS, 2015, 42 : S88 - S89
  • [30] Evaluation of bias in weighted residual calculations when handling below the limit of quantification data using Beal's M3 method
    Jaber, Mutaz M.
    Cheng, Shen
    Brundage, Richard C.
    CPT-PHARMACOMETRICS & SYSTEMS PHARMACOLOGY, 2021, 10 (04): : 275 - 278