Initial Experience with the 4D Mini-TEE Probe in the Adult Population

被引:0
|
作者
Papadopoulos, Konstantinos [1 ]
Ikonomidis, Ignatios [2 ]
Coisne, Augustin [3 ,4 ]
Kayhan, Ozge Ozden [5 ]
Tzikas, Apostolos [6 ,7 ]
Fragakis, Nikolaos [7 ]
Antoniadis, Antonios P. [7 ]
Vannan, Mani A. [8 ]
Donal, Erwan [9 ]
机构
[1] European Interbalkan Med Ctr, Echocardiog Lab, Thessaloniki 57001, Greece
[2] Natl & Kapodistrian Univ Athens, Attikon Univ Hosp, Med Sch, Echocardiog Lab,Cardiol Dept 2, Athens 12462, Greece
[3] Univ Lille, Inst Pasteur Lille, European Genom Inst Diabet EGID, INSERM,CHU Lille,U1011, F-59000 Lille, France
[4] Cardiovasc Res Fdn, New York, NY 10019 USA
[5] Mem Bahcelievler Hosp, Cardiol Dept, TR-34180 Istanbul, Turkiye
[6] European Interbalkan Med Ctr, Cardiol Dept, Thessaloniki 57001, Greece
[7] Aristotle Univ Thessaloniki, Gen Hosp Hippokration, Fac Hlth Sci, Dept Cardiol 2,Sch Med, Thessaloniki 54642, Greece
[8] Piedmont Heart Inst, Struct & Valvular Ctr Excellence, Marcus Heart Valve Ctr, Atlanta, GA 30309 USA
[9] Univ Rennes, CHU Rennes, INSERM, LTSI UMR 1099, F-35000 Rennes, France
关键词
transesophageal echocardiography; mini-TEE probe; three-dimensional echocardiography; transcatheter interventions; 3-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY; ATRIAL APPENDAGE OCCLUSION; HEART-DISEASE; AMERICAN SOCIETY; 1ST EXPERIENCE; GUIDANCE; MITRACLIP; FEASIBILITY; GUIDELINES;
D O I
10.3390/jcm13216450
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transesophageal echocardiography (TEE) is a vital diagnostic tool in clinical practice, particularly in transcatheter interventions where it aids in both pre-operative planning and intra-operative guidance. Traditional TEE probes often require general anesthesia due to patient discomfort. However, the development of miniaturized TEE probes presents a promising alternative, enabling routine examinations and interventions with minimal sedation. This study evaluates the feasibility of performing a complete 2D/4D TEE protocol with the new 4D mini-TEE probe in the echocardiography department and its application in transcatheter interventions. Methods: This is a retrospective study that included 30 consecutive patients from two high-volume European hospitals (Interbalkan Medical Center, Thessaloniki, Greece, and Rennes University, France) that underwent TEE or transcatheter interventions. The new 4D mini-TEE 9VT-D probe (GE Healthcare) was utilized. The quality of the images and the tolerance of the probe were assessed in the cath lab during interventions and in the echocardiography department during routine TEE examinations. Results: Direct comparison of the 4D mini-TEE probe with the standard 6VT-D probe confirmed the excellent image quality of this new pediatric probe. Most of the patients required minimal sedation or local oropharyngeal anesthesia, with satisfactory tolerance reported. Most of the transcatheter procedures did not require general anesthesia and intubation, resulting in shorter procedural time. Both 2D and 4D imaging modalities offered adequate intra-operative guidance for transcatheter procedures. Conclusions: The 4D mini-TEE probe delivers exceptional imaging capabilities for routine examinations and transcatheter interventions without needing sedation. Its use reduces esophageal trauma and the need for general anesthesia, enhancing patient comfort and safety.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Initial evaluation of a direct 4D PET parametric image reconstruction method
    Yan, Jianhua
    Planeta-Wilson, Beata
    Carson, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [32] A phosphodiesterase 4D polymorphism is not associated with ischaemic stroke in the Korean population
    Kim, M. K.
    Shon, E. J.
    JOURNAL OF NEUROLOGY, 2006, 253 : 88 - 89
  • [33] Association of phosphodiesterase 4D gene with ischemic stroke in a Pakistani population
    Saleheen, D
    Bukhari, S
    Haider, SR
    Nazir, A
    Khanum, S
    Shafqat, S
    Anis, K
    Frossard, P
    STROKE, 2005, 36 (10) : 2275 - 2277
  • [34] Combining position-based dynamics and gradient vector flow for 4D mitral valve segmentation in TEE sequences
    Lennart Tautz
    Lars Walczak
    Joachim Georgii
    Amer Jazaerli
    Katharina Vellguth
    Isaac Wamala
    Simon Sündermann
    Volkmar Falk
    Anja Hennemuth
    International Journal of Computer Assisted Radiology and Surgery, 2020, 15 : 119 - 128
  • [35] Combining position-based dynamics and gradient vector flow for 4D mitral valve segmentation in TEE sequences
    Tautz, Lennart
    Walczak, Lars
    Georgii, Joachim
    Jazaerli, Amer
    Vellguth, Katharina
    Wamala, Isaac
    Suendermann, Simon
    Falk, Volkmar
    Hennemuth, Anja
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2020, 15 (01) : 119 - 128
  • [36] PHOTOIONIZATION CROSS-SECTIONS AS A PROBE OF 4D HYBRIDIZATION IN DILUTE AG ALLOYS
    COLE, RJ
    WEIGHTMAN, P
    JENNISON, DR
    STECHEL, EB
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1994, 68 : 139 - 143
  • [37] Non-contrast myocardial perfusion using a novel 4D magnetic resonance arterial spin labeling technique: Initial experience
    Miyazaki, Mitsue
    Zhou, Xiangzhi
    Hoshino, Tsutomu
    Yokoyama, Kenichi
    Ishimura, Rieko
    Nitatori, Toshiaki
    MICROVASCULAR RESEARCH, 2015, 98 : 94 - 101
  • [38] 4D visualization of the left ventricle, using a rotating ultrasound probe during 4 cardiac cycles
    LESI , Université d'Orléans, 12, rue de Blois BP 6744, Orléans Cedex 2
    45067, France
    不详
    Journal of Computing and Information Technology, 1998, 6 (04): : 463 - 476
  • [39] Phosphodiesterase 4D (PDE4D) Gene Variants and Risk of Ischemic Stroke in the Taiwanese Population
    Hsieh, Ming-Song
    Yu, Shu-Chuan
    Chung, Wing-Ten
    Hsueh, Yu-Mei
    Chen, Feng-Chia
    Chiu, Wen-Ta
    Lee, Horng-Mo
    LABMEDICINE, 2009, 40 (02): : 87 - 90
  • [40] 2D:4D RATIO DIFFERS IN ISCHEMIC STROKE: A SINGLE CENTER EXPERIENCE
    Yang, Ke
    Ding, XianHui
    Zhou, ZhiMing
    Shi, XiaoLei
    TRANSLATIONAL NEUROSCIENCE, 2018, 9 (01) : 142 - 146