POINT-OF-CARE POTASSIUM MEASUREMENT VS ARTIFICIAL INTELLIGENCE-ENABLED ELECTROCARDIOGRAPHY FOR HYPERKALEMIA DETECTION

被引:0
|
作者
Lin, Chin [1 ]
Chen, Chien-Chou [2 ]
Lin, Chin-Sheng [2 ]
Shang, Hung-Sheng [3 ]
Lee, Chia-Cheng [4 ,5 ]
Chau, Tom [6 ]
Lin, Shih-Hua [2 ]
机构
[1] Natl Def Med Ctr, Sch Med, Taipei, Taiwan
[2] Triserv Gen Hosp, Natl Def Med Ctr, Dept Med, Div Nephrol, Taipei, Taiwan
[3] Triserv Gen Hosp, Natl Def Med Ctr, Dept Pathol, Div Clin Pathol, Taipei, Taiwan
[4] Triserv Gen Hosp, Natl Def Med Ctr, Dept Med Informat, Taipei, Taiwan
[5] Triserv Gen Hosp, Dept Surg, Natl Def Med Ctr, Div Colorectal Surg, Taipei, Taiwan
[6] Providence St Vincent Med Ctr, Dept Med, Portland, OR USA
关键词
KIDNEY-DISEASE;
D O I
10.4037/ajcc2025597
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Hyperkalemia can be detected by point-of- care (POC) blood testing and by artificial intelligence- enabled electrocardiography (ECG).These 2 methods of detecting hyperkalemia have not been compared. Objective To determine the accuracy of POC and ECG potassium measurements for hyperkalemia detection in patients with critical illness. Methods This retrospective study involved intensive care patients in an academic medical center from October 2020 to September 2021. Patients who had 12-lead ECG, POC potassium measurement, and central laboratory potassium measurement within 1 hour were included.The POC potassium measurements were obtained from arterial blood gas analysis; ECG potassium measurements were calculated by a previously developed deep learning model. Hyperkalemia was defined as a central laboratory potassium measurement of 5.5 mEq/L or greater. Results Fifteen patients with hyperkalemia and 252 patients without hyperkalemia were included.The POC and ECG potassium measurements were available about 35 minutes earlier than central laboratory results. Correlation with central laboratory potassium measurement was better for POC testing than for ECG (mean absolute errors of 0.211 mEq/L and 0.684 mEq/L, respectively). For POC potassium measurement, area under the receiver operating characteristic curve (AUC) to detect hyperkalemia was 0.933, sensitivity was 73.3%, and specificity was 98.4%. For ECG potassium measurement, AUC was 0.884, sensitivity was 93.3%, and specificity was 63.5%. Conclusions The ECG potassium measurement, with its high sensitivity and coverage rate, may be used initially and followed by POC potassium measurement for rapid detection of life-threatening hyperkalemia. ( American Journal of Critical Care. 2025;34:41-51)
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Improving detection of obstructive coronary artery disease with an artificial intelligence-enabled electrocardiogram algorithm
    Lee, Yin-Hao
    Hsieh, Ming-Tsung
    Chang, Chun-Chin
    Tsai, Yi-Lin
    Chou, Ruey-Hsing
    Lu, Henry Hong-Shing
    Huang, Po-Hsun
    ATHEROSCLEROSIS, 2023, 381
  • [42] Artificial intelligence-enabled coconut tree disease detection and classification model for smart agriculture
    Maray, Mohammed
    Albraikan, Amani Abdulrahman
    Alotaibi, Saud S.
    Alabdan, Rana
    Al Duhayyim, Mesfer
    Al-Azzawi, Waleed Khaild
    Alkhayyat, Ahmed
    COMPUTERS & ELECTRICAL ENGINEERING, 2022, 104
  • [43] Artificial Intelligence-Enabled Smartwatch Used for the Detection of Idiopathic Ventricular Tachycardia: A Case Report
    Kumar, Sumit
    Banerjee, Arijita
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [44] Artificial Intelligence-Enabled Electrocardiogram in the Detection of Patients at Risk of Atrial Secondary Mitral Regurgitation
    Naser, Jwan A.
    Lee, Eunjung
    Michelena, Hector I.
    Lin, Grace
    Pellikka, Patricia A.
    Nkomo, Vuyisile T.
    Noseworthy, Peter A.
    Friedman, Paul A.
    Attia, Zachi I.
    Pislaru, Sorin V.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2023, 16 (09): : 552 - 554
  • [45] Artificial Intelligence-Enabled DDoS Detection for Blockchain-Based Smart Transport Systems
    Liu, Tong
    Sabrina, Fariza
    Jang-Jaccard, Julian
    Xu, Wen
    Wei, Yuanyuan
    SENSORS, 2022, 22 (01)
  • [46] Artificial intelligence-enabled fully automated detection of cardiac amyloidosis using electrocardiograms and echocardiograms
    Goto, Shinichi
    Mahara, Keitaro
    Beussink-Nelson, Lauren
    Ikura, Hidehiko
    Katsumata, Yoshinori
    Endo, Jin
    Gaggin, Hanna K.
    Shah, Sanjiv J.
    Itabashi, Yuji
    MacRae, Calum A.
    Deo, Rahul C.
    NATURE COMMUNICATIONS, 2021, 12 (01)
  • [47] Artificial intelligence-enabled fully automated detection of cardiac amyloidosis using electrocardiograms and echocardiograms
    Shinichi Goto
    Keitaro Mahara
    Lauren Beussink-Nelson
    Hidehiko Ikura
    Yoshinori Katsumata
    Jin Endo
    Hanna K. Gaggin
    Sanjiv J. Shah
    Yuji Itabashi
    Calum A. MacRae
    Rahul C. Deo
    Nature Communications, 12
  • [48] Acoustofluidic Micromixing Enabled Hybrid Integrated Colorimetric Sensing, for Rapid Point-of-Care Measurement of Salivary Potassium
    Surendran, Vikram
    Chiulli, Thomas
    Manoharan, Swetha
    Knisley, Stephen
    Packirisamy, Muthukumaran
    Chandrasekaran, Arvind
    BIOSENSORS-BASEL, 2019, 9 (02):
  • [49] Using artificial intelligence to classify point-of-care ultrasound images
    Anderson, Owen
    Reagan, Garrett
    Hugenberg, Nicholas
    Mandale, Deepa
    Wen, Songnan
    Naqvi, Tasneem
    Adusei, Shaheeda
    Holmes, David, III
    IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, MEDICAL IMAGING 2024, 2024, 12928
  • [50] Artificial Intelligence-Enabled Acoustic Analysis Technology for Accurate Detection and Interpretation of Breath Sounds in Children
    Cheng, Z. R.
    Zhang, H. Y.
    Thomas, B.
    Tan, Y. H.
    Teoh, O. H.
    Pugalenthi, A.
    PEDIATRIC PULMONOLOGY, 2019, 54 : S79 - S80