POINT-OF-CARE POTASSIUM MEASUREMENT VS ARTIFICIAL INTELLIGENCE-ENABLED ELECTROCARDIOGRAPHY FOR HYPERKALEMIA DETECTION

被引:0
|
作者
Lin, Chin [1 ]
Chen, Chien-Chou [2 ]
Lin, Chin-Sheng [2 ]
Shang, Hung-Sheng [3 ]
Lee, Chia-Cheng [4 ,5 ]
Chau, Tom [6 ]
Lin, Shih-Hua [2 ]
机构
[1] Natl Def Med Ctr, Sch Med, Taipei, Taiwan
[2] Triserv Gen Hosp, Natl Def Med Ctr, Dept Med, Div Nephrol, Taipei, Taiwan
[3] Triserv Gen Hosp, Natl Def Med Ctr, Dept Pathol, Div Clin Pathol, Taipei, Taiwan
[4] Triserv Gen Hosp, Natl Def Med Ctr, Dept Med Informat, Taipei, Taiwan
[5] Triserv Gen Hosp, Dept Surg, Natl Def Med Ctr, Div Colorectal Surg, Taipei, Taiwan
[6] Providence St Vincent Med Ctr, Dept Med, Portland, OR USA
关键词
KIDNEY-DISEASE;
D O I
10.4037/ajcc2025597
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Hyperkalemia can be detected by point-of- care (POC) blood testing and by artificial intelligence- enabled electrocardiography (ECG).These 2 methods of detecting hyperkalemia have not been compared. Objective To determine the accuracy of POC and ECG potassium measurements for hyperkalemia detection in patients with critical illness. Methods This retrospective study involved intensive care patients in an academic medical center from October 2020 to September 2021. Patients who had 12-lead ECG, POC potassium measurement, and central laboratory potassium measurement within 1 hour were included.The POC potassium measurements were obtained from arterial blood gas analysis; ECG potassium measurements were calculated by a previously developed deep learning model. Hyperkalemia was defined as a central laboratory potassium measurement of 5.5 mEq/L or greater. Results Fifteen patients with hyperkalemia and 252 patients without hyperkalemia were included.The POC and ECG potassium measurements were available about 35 minutes earlier than central laboratory results. Correlation with central laboratory potassium measurement was better for POC testing than for ECG (mean absolute errors of 0.211 mEq/L and 0.684 mEq/L, respectively). For POC potassium measurement, area under the receiver operating characteristic curve (AUC) to detect hyperkalemia was 0.933, sensitivity was 73.3%, and specificity was 98.4%. For ECG potassium measurement, AUC was 0.884, sensitivity was 93.3%, and specificity was 63.5%. Conclusions The ECG potassium measurement, with its high sensitivity and coverage rate, may be used initially and followed by POC potassium measurement for rapid detection of life-threatening hyperkalemia. ( American Journal of Critical Care. 2025;34:41-51)
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Role of Artificial Intelligence-Enabled Electrocardiography in the Management and Outcome Prediction of Coexisting Hyperkalemia and Bradycardia
    Chen Chien-Chou
    Lin Chin
    Shih Chi Wei
    Lu Ang
    Lin, Shih-Hua P.
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2024, 35 (10):
  • [2] Prediction of certainty in artificial intelligence-enabled electrocardiography
    Demolder, Anthony
    Nauwynck, Maxime
    De Pauw, Michel
    De Buyzere, Marc
    Duytschaever, Mattias
    Timmermans, Frank
    De Pooter, Jan
    JOURNAL OF ELECTROCARDIOLOGY, 2024, 83 : 71 - 79
  • [3] Detection of Left Atrial Myopathy Using Artificial Intelligence-Enabled Electrocardiography
    Verbrugge, Frederik H.
    Reddy, Yogesh N. V.
    Attia, Zachi I.
    Friedman, Paul A.
    Noseworthy, Peter A.
    Lopez-Jimenez, Francisco
    Kapa, Suraj
    Borlaug, Barry A.
    CIRCULATION-HEART FAILURE, 2022, 15 (01) : E008176
  • [4] DETECTION OF HYPERTROPHIC CARDIOMYOPATHY BY ARTIFICIAL INTELLIGENCE-ENABLED ELECTROCARDIOGRAPHY IN CHILDREN AND ADOLESCENTS
    Siontis, Konstantinos
    Liu, Kan
    Bos, J. Martijn
    Attia, Zachi Itzhak
    Arruda-Olson, Adelaide
    Farahani, Nasibeh Z.
    Friedman, Paul
    Noseworthy, Peter
    Ackerman, Michael
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 3247 - 3247
  • [5] Artificial intelligence-enabled electrocardiography contributes to hyperthyroidism detection and outcome prediction
    Chin Lin
    Feng-Chih Kuo
    Tom Chau
    Jui-Hu Shih
    Chin-Sheng Lin
    Chien-Chou Chen
    Chia-Cheng Lee
    Shih-Hua Lin
    Communications Medicine, 4 (1):
  • [6] Artificial Intelligence-Enabled Electrocardiography to Screen Patients with Dilated Cardiomyopathy
    Shrivastava, Sanskriti
    Cohen-Shelly, Michal
    Attia, Zachi I.
    Rosenbaum, Andrew N.
    Wang, Liwei
    Giudicessi, John R.
    Redfield, Margaret
    Bailey, Kent
    Lopez-Jimenez, Francisco
    Lin, Grace
    Kapa, Suraj
    Friedman, Paul A.
    Pereira, Naveen L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2021, 155 : 121 - 127
  • [7] APPLICATION OF ARTIFICIAL INTELLIGENCE-ENABLED ELECTROCARDIOGRAPHY IN FAMILIAL DILATED CARDIOMYOPATHY
    Shrivastava, Sanskriti
    Shelly, Michal
    Attia, Zachi Itzhak
    Rosenbaum, Andrew
    Lopez-Jimenez, Francisco
    Bailey, Kent
    Kapa, Suraj
    Friedman, Paul
    Pereira, Naveen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 3471 - 3471
  • [8] Point-of-care artificial intelligence-enabled ECG for dyskalemia: a retrospective cohort analysis for accuracy and outcome prediction
    Lin, Chin
    Chau, Tom
    Lin, Chin-Sheng
    Shang, Hung-Sheng
    Fang, Wen-Hui
    Lee, Ding-Jie
    Lee, Chia-Cheng
    Tsai, Shi-Hung
    Wang, Chih-Hung
    Lin, Shih-Hua
    NPJ DIGITAL MEDICINE, 2022, 5 (01)
  • [9] Point-of-care artificial intelligence-enabled ECG for dyskalemia: a retrospective cohort analysis for accuracy and outcome prediction
    Chin Lin
    Tom Chau
    Chin-Sheng Lin
    Hung-Sheng Shang
    Wen-Hui Fang
    Ding-Jie Lee
    Chia-Cheng Lee
    Shi-Hung Tsai
    Chih-Hung Wang
    Shih-Hua Lin
    npj Digital Medicine, 5
  • [10] Performance of a point-of-care ultrasound platform for artificial intelligence-enabled assessment of pulmonary B-lines
    Labaf, Ashkan
    ahman-Persson, Linda
    Husu, Leo Silven
    Smith, J. Gustav
    Ingvarsson, Annika
    Evaldsson, Anna Werther
    CARDIOVASCULAR ULTRASOUND, 2025, 23 (01)