AAPM Task Group Report 274: Fluence rate dosimetry for photodynamic therapy (PDT)

被引:0
|
作者
Zhu, Timothy C. [1 ]
Pogue, Brian W. [2 ]
Dimofte, Andreea [1 ]
Finlay, Jarod C. [1 ]
Lilge, Lothar [3 ,4 ]
Sunar, Ulas [5 ]
Simone II, Charles B. [6 ]
van Veen, Robert L. P. [7 ]
机构
[1] Univ Penn, Philadelphia, PA USA
[2] Univ Wisconsin, Madison, WI USA
[3] Univ Toronto, Toronto, ON, Canada
[4] Univ Hlth Network, Toronto, ON, Canada
[5] SUNY Stony Brook, Stony Brook, NY USA
[6] New York Proton Ctr, New York, NY USA
[7] Antoni van Leeuwenhoek Hosp, NKI AvL, Netherlands Canc Inst, Amsterdam, Netherlands
关键词
in vivo dosimetry; light fluence; photodynamic therapy; TG274; VIVO LIGHT DOSIMETRY; OPTICAL-FIBER PROBES; IN-VIVO; SCATTERING BULBS; HUMAN PROSTATE; CALIBRATION; HEAD; DETECTORS; TISSUES; CANCER;
D O I
10.1002/mp.17613
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Photodynamic therapy (PDT) is a treatment modality clinically approved for several oncologic indications, including esophageal and endobronchial cancers, precancerous conditions including Barrett's esophagus and actinic keratosis, and benign conditions like age-related macular degeneration. While it is currently clinically underused, PDT is an area of significant research interest. Because PDT relies on the absorption of light energy by intrinsic or administered absorbers, the dosimetric quantity of interest is the absorbed energy per unit mass of tissue, proportional to the fluence rate of light in tissue. It has been demonstrated that the fluence rate at the tissue surface may differ significantly from the incident irradiance of light because of multiple scattering and absorption, both of which may vary among patients and tissue types. This report will review the current state-of-the-art fluence rate dosimetry technology. It will describe the two types of detectors currently available for fluence rate measurement, scattering-tip and fluorescence-based detectors, and review their principles of operation. The report will recommend strategies to establish calibration and quality assurance procedures for clinical fluence rate dosimetry equipment, and it will establish guidelines for clinical implementation of fluence rate dosimetry.
引用
收藏
页码:1354 / 1371
页数:18
相关论文
共 50 条
  • [21] AAPM task group report 314: Fault recovery in external beam radiation therapy
    Sutlief, Steven
    Buckey, Courtney
    Ibbott, Geoffrey
    Hadley, Scott
    Curran, Bruce
    Siochi, Ramon Alfredo
    Tripathi, Sugata
    Perrin, David
    Young, Cheryl
    Negrut, Cristina
    Robertson, Ian
    Koehl, Susan
    Shi, Jie
    MEDICAL PHYSICS, 2025, 52 (01) : 21 - 44
  • [22] Refinements to the geometry factor used in the AAPM Task Group Report No. 43 necessary for brachytherapy dosimetry calculations
    Rivard, MJ
    MEDICAL PHYSICS, 1999, 26 (11) : 2445 - 2450
  • [23] Effects of fluence rate on cytotoxicity during photodynamic therapy
    Sitnik, TM
    Henderson, BW
    OPTICAL METHODS FOR TUMOR TREATMENT AND DETECTION: MECHANISMS AND TECHNIQUES IN PHOTODYNAMIC THERAPY VI, PROCEEDINGS OF, 1997, 2972 : 95 - 102
  • [24] Photoacoustic visualization of the fluence rate dependence of photodynamic therapy
    Gao, Rongkang
    Xu, Hao
    Liu, Liangjian
    Zhang, Ying
    Yin, Ting
    Zhou, Huichao
    Sun, Mingjian
    Chen, Ningbo
    Ren, Yaguang
    Chen, Tao
    Pan, Yinhao
    Zheng, Mingbin
    Ohulchanskyy, Tymish Y.
    Zheng, Rongqin
    Cai, Lintao
    Song, Liang
    Qu, Junle
    Liu, Chengbo
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (08) : 4203 - 4223
  • [25] Recommendations on the practice of calibration, dosimetry, and quality assurance for gamma stereotactic radiosurgery: Report of AAPM Task Group 178
    Petti, Paula L.
    Rivard, Mark J.
    Alvarez, Paola E.
    Bednarz, Greg
    Daniel Bourland, J.
    DeWerd, Larry A.
    Drzymala, Robert E.
    Johansson, Jonas
    Kunugi, Keith
    Ma, Lijun
    Meltsner, Sheridan G.
    Neyman, Gennady
    Seuntjens, Jan P.
    Shiu, Almon S.
    Goetsch, Steven J.
    MEDICAL PHYSICS, 2021, 48 (07) : E733 - E770
  • [26] Functional fitting of interstitial brachytherapy dosimetry data recommended by the AAPM Radiation Therapy Committee Task Group 43
    Furhang, EE
    Anderson, LL
    MEDICAL PHYSICS, 1999, 26 (02) : 153 - 160
  • [27] High dose-rate brachytherapy treatment delivery: Report of the AAPM Radiation Therapy Committee Task Group No. 59
    Kubo, HD
    Glasgow, GP
    Pethel, TD
    Thomadsen, BR
    Williamson, JF
    MEDICAL PHYSICS, 1998, 25 (04) : 375 - 403
  • [28] PDT dose dosimetry for Photofrin-mediated pleural photodynamic therapy (pPDT)
    Ong, Yi Hong
    Kim, Michele M.
    Finlay, Jarod C.
    Dimofte, Andreea
    Singhal, Sunil
    Glatstein, Eli
    Cengel, Keith A.
    Zhu, Timothy C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (01):
  • [29] Stereotactic body radiation therapy: (1) Highlights of the AAPM task group report 101 on SBRT
    Benedict, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2176 - 2176
  • [30] Clinical PDT dose dosimetry for pleural Photofrin-mediated photodynamic therapy
    Sun, Hongjing
    Ong, Yihong
    Yang, Weibing
    Sourvanos, Dennis
    Dimofte, Andreea
    Busch, Theresa M.
    Singhal, Sunil
    Cengel, Keith A.
    Zhu, Timothy C.
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29 (01)