Creation and Improvement Principles of the Pneumatic Manual Impulse Devices

被引:2
|
作者
Vorobiov, Iurii [1 ]
Maiorova, Kateryna [1 ]
Voronko, Iryna [1 ]
Boiko, Maksym [1 ]
Komisarov, Oleh [2 ]
机构
[1] Natl Aerosp Univ, Kharkiv Aviat Inst, 17 Chkalova St, UA-61070 Kharkiv, Ukraine
[2] Motor Sich JSC, 15 Motorostroiteley Ave, UA-69068 Zaporozhe, Ukraine
关键词
Pneumatic manual impulse device; ANSYS CFX system; Blow energy; Striker; Finite element method;
D O I
10.1007/978-3-030-94259-5_17
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The aircraft structures complexity and the inaccessibility of rivets setting areas create the need for manual rivet hammers. Many developments in this area provide a wide range of tools for the assembly work. During the assembly work, the multiple-hitting pneumatic impulse hammers are used. Such kind of tools create noise and vibrations that affect a fitter. Moreover, such equipment can be used only by a highly qualified specialist. The purpose of the study is to determine the pneumatic manual impulse devices (PMID) blow energy required to auto-mate the devices design process, taking into account their design features. The engineering process of the PMID operation is simulated using the ANSYS CFX Software. For the numerical study of the problem, a system of Navier-Stokes equations is used. To determine the optimal configuration of the devices gas tracts, energy losses and stress-stain state of structural elements in their interaction, the finite element method is used. As a result of the study, the simulation with various geometry of computational domain has been carried out. The results of different approaches to reduce the calculation time when using 2D geometry are compared. Using the results of gas-dynamic calculations of the devices energy parameters, the task of designing the PMID with the required blow energy has been solved. The comparison of the simulation results made in the ANSYS CFX software with the theoretical data revealed the insignificant error, the maximum value of which is 12%. It may be caused by using many simplifications during the theoretical calculations.
引用
收藏
页码:178 / 191
页数:14
相关论文
共 50 条
  • [41] Improvement of vibration control of a pneumatic shaker
    Men, Shouqiang
    Xu, Jingwen
    Zhou, Jun
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON MECHATRONICS, CONTROL AND ELECTRONIC ENGINEERING, 2014, 113 : 746 - 749
  • [42] Improvement of manual plasmocytapheresis technology
    Voenno-Meditsinskaya Akad, Sankt-Peterburg, Russia
    Meditsinskaya Tekhnika, 1998, (03): : 34 - 36
  • [43] IMPROVEMENT OF GOLAY PNEUMATIC INFRARED RECEPTOR
    MUNIER, JM
    HADNI, A
    REVUE DE PHYSIQUE APPLIQUEE, 1970, 5 (06): : 845 - &
  • [44] Improvement in survival after mechanical circulatory support with pneumatic pulsatile ventricular assist devices in small infants and children
    Hetzer, R.
    Potapov, E., V
    Stiller, B.
    Weng, Y.
    Huebler, M.
    Lemmer, J.
    Alexi-Meskishvili, V
    Redlin, M.
    Merkle, F.
    Kaufmann, F.
    Hennig, E.
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2005, 19 (05): : 193 - 201
  • [45] Improvement of manual plasmacytapheresis technology
    Zhiburt E.B.
    Popova N.N.
    Baratashvili G.G.
    Sidorkevich S.V.
    Svintsova O.V.
    Biomedical Engineering, 1998, 32 (3) : 159 - 161
  • [46] Manual riveting process improvement
    Bahr, B.
    Xiao, X.
    Aerospace Engineering (Warrendale, Pennsylvania), 1995, 15 (09): : 16 - 18
  • [48] ADVANCED PNEUMATIC IMPULSE ICE PROTECTION SYSTEM (PIIP) FOR AIRCRAFT
    MARTIN, CA
    PUTT, JC
    JOURNAL OF AIRCRAFT, 1992, 29 (04): : 714 - 716
  • [49] THE ROLE OF IMPULSE VARIABILITY IN MANUAL-AIMING ASYMMETRIES
    CARSON, RG
    ELLIOTT, D
    GOODMAN, D
    THYER, L
    CHUA, R
    ROY, EA
    PSYCHOLOGICAL RESEARCH-PSYCHOLOGISCHE FORSCHUNG, 1993, 55 (04): : 291 - 298
  • [50] AN ISOTHERMAL CALORIMETER WITH PNEUMATIC COMPENSATION - PRINCIPLES AND APPLICATION
    TERMINASSIAN, L
    MILLIOU, F
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (05): : 450 - 455