An improved method for evaluating fracture density using pulsed neutron capture logging

被引:0
|
作者
Zhang, Feng [1 ,2 ,3 ]
Xie, Bing [3 ,4 ]
Chen, Qian [5 ]
Zhang, Xiaoyang [3 ]
ABuLaHai, YiMula [3 ]
Lu, Baoping [6 ]
Zhang, Hui [3 ]
Fan, Jilin [3 ]
机构
[1] State Key Lab Deep Oil & Gas, Qingdao, Peoples R China
[2] Laoshan Lab, Qingdao, Peoples R China
[3] China Univ Petr, Qingdao, Peoples R China
[4] China Petr & Chem Corp, Beijing, Peoples R China
[5] Sinopec Matrix Corp, Qingdao, Peoples R China
[6] China Natl Logging Corp, Xian, Peoples R China
基金
中国国家自然科学基金;
关键词
GAMMA DENSITY; GEANT4; PROPAGATION;
D O I
10.1190/GEO2023-0206.1
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Fracture density is a critical fracture evaluation parameter for the optimization and production prediction of hydraulic fracturing models. Nonradioactive tracer (NRT) techniques have successfully used a quantitative fracture density method based on neutron-induced gamma rays from formation elements. Furthermore, fracture density can be calculated using the formation capture cross section before and after hydraulic fracturing based on pulsed neutron capture logging. However, the response sensitivity of the macroscopic scattering cross section to the fractures decreases when the fracture density is high due to the neutron self-shielding phenomenon. Therefore, an improved fracture density evaluation method is applied, which combines the macroscopic capture cross section and the neutron self-shielding correction factor. In the new method, the peak area of titanium from the captured gamma spectrum is used to obtain a neutron self-shielding correction factor to improve the sensitivity of fracture density determination. Furthermore, the response of capture cross-section variation to fracture density at various tagged proppant concentrations and formation backgrounds is investigated. The findings indicate that the tagged proppant concentration influences the detection limit of fracture density and the sensitivity of fracture density identification. The accurate calculation range of fracture density using the new method has been extended from 5% to 10% under the condition that the tagged proppant concentration is 0.2%. Meanwhile, whereas water salinity significantly impacts capture cross-section variation, the effects of porosity, lithology, and fluid type on capture cross-section variation are negligible. A simulated fracturing example demonstrates the method's applicability in various measurement environments. The results show that fracture density and height are consistent with the model settings after correcting for water salinity, and the fracture density calculation error is less than 3%. Therefore, our evaluation method for fracture density corrected for the neutron self-shielding effect improves response sensitivity and fracture density calculation accuracy.
引用
收藏
页码:D275 / D285
页数:11
相关论文
共 50 条
  • [41] A method of monitoring gas saturation in carbon dioxide injection heavy oil reservoirs by pulsed neutron logging technology
    Fan J.
    Zhang F.
    Tian L.
    Liang Q.
    Zhang X.
    Fang Q.
    Lu B.
    Li X.
    Shiyou Kantan Yu Kaifa/Petroleum Exploration and Development, 2021, 48 (06): : 1232 - 1240
  • [42] AN APPROXIMATE METHOD FOR EVALUATING NEUTRON CAPTURE IN 240PU RESONANCE AT 1EV
    GRIGGS, CF
    JOURNAL OF NUCLEAR ENERGY PARTS A AND B-REACTOR SCIENCE AND TECHNOLOGY, 1965, 19 (11PA): : 891 - &
  • [43] MAXIMUM DENSITY AND CAPTURE RATE OF NEUTRON MODERATED FROM A PULSED SOURCE IMPLICATIONS FOR GAMMA-RAY LASERS
    BALDWIN, GC
    SOLEM, JC
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (04): : 596 - 596
  • [44] Improving the pulsed neutron-gamma density method with machine learning regression algorithms
    Dong, Duo
    Wu, Wensheng
    Yue, Wenzheng
    Ge, Yunlong
    Xiong, Shitao
    Zhao, Wenqi
    Wang, Ruifeng
    Journal of Petroleum Science and Engineering, 2022, 218
  • [45] An improved method of using traction in the treatment of fracture of the femur
    Stimson, LA
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1910, 54 : 462 - 463
  • [46] Improving the pulsed neutron-gamma density method with machine learning regression algorithms
    Dong, Duo
    Wu, Wensheng
    Yue, Wenzheng
    Ge, Yunlong
    Xiong, Shitao
    Zhao, Wenqi
    Wang, Ruifeng
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2022, 218
  • [47] URANIUM ASSAY LOGGING USING A PULSED 14-MEV NEUTRON SOURCE AND DETECTION OF DELAYED FISSION NEUTRONS
    GIVENS, WW
    MILLS, WR
    DENNIS, CL
    CALDWELL, RL
    GEOPHYSICS, 1976, 41 (02) : 353 - 353
  • [48] URANIUM ASSAY LOGGING USING A PULSED 14-MEV NEUTRON SOURCE AND DETECTION OF DELAYED FISSION NEUTRONS
    GIVENS, WW
    MILLS, WR
    DENNIS, CL
    CALDWELL, RL
    GEOPHYSICS, 1976, 41 (03) : 468 - 490
  • [49] COMPLETE COMPOSITION AND DENSITY CORRELATED SAMPLING IN THE SPECIFIC PURPOSE MONTE-CARLO CODES MCPNL AND MCDNL FOR SIMULATING PULSED NEUTRON AND NEUTRON POROSITY LOGGING TOOLS
    GARDNER, RP
    MICKAEL, MW
    VERGHESE, K
    NUCLEAR GEOPHYSICS, 1989, 3 (03): : 157 - 165
  • [50] A method for identifying the thin layer using the wavelet transform of density logging data
    Zhang, Quanying
    Zhang, Feng
    Liu, Juntao
    Wang, Xinguang
    Chen, Qian
    Zhao, Liang
    Tian, Lili
    Wang, Yang
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2018, 160 : 433 - 441