Fluid responsiveness of ambulatory paediatric patients with a Fontan circulation by passive leg raising

被引:0
|
作者
Harteveld, Lisette M. [1 ,2 ]
Blom, Nico A. [1 ,2 ,3 ]
van Dijk, J. Gert [4 ]
Reijntjes, Robert H. A. M. [4 ]
van Someren, Paul J. [4 ]
Kerkhof, Fabian I. [4 ]
Kuipers, Irene M. [1 ,3 ]
Rammeloo, Lukas A. J. [1 ,3 ]
ten Harkel, Arend D. J. [1 ,2 ]
机构
[1] Ctr Congenital Heart Dis Amsterdam Leiden, Leiden, Netherlands
[2] Leiden Univ, Willem Alexander Childrens Hosp, Dept Paediat, Div Paediat Cardiol,Med Ctr, Leiden, Netherlands
[3] Univ Amsterdam, Dept Paediat Cardiol, Med Ctr, Amsterdam, Netherlands
[4] Leiden Univ, Dept Neurol & Clin Neurophysiol, Med Ctr, Leiden, Netherlands
关键词
Fontan physiology; single ventricle; passive leg raising; fluid responsiveness; haemodynamics;
D O I
10.1017/S1047951125001209
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Passive leg raising is used to predict who will benefit from fluid therapy in critically ill patients, including children. Patients with a Fontan circulation may have a different haemodynamic response to a fluid challenge by passive leg raising.Methods: The haemodynamic response of 31 paediatric patients with a Fontan circulation from the outpatient clinic (median age 14.0 years) and 35 healthy controls (median age 12.8 years) to passive leg raising was evaluated non-invasively by echocardiography for the assessment of, e.g., velocity time integral across the (neo)aortic valve, blood pressure measurements, and respiration. Participants were considered responders when the velocity time integral increased >= 10.0%.Results: Overall, patients and controls did not differ in the haemodynamic response. Twelve patients (38.7%) and 8 controls (22.9%) were responders, which was not statistically different (P = 0.22). Responders in the patient and control group also had a similar echo-estimated velocity time integral increase of + 18.9% and + 15.2%, respectively (P = 0.91). There was no difference in echo-estimated velocity time integral change between patient and control non-responders with a decrease of -1.4% and -6.4%, respectively (P = 0.70) and no difference in the amount of patients who were negatively affected by passive leg raising, ith a decrease of <=-10.0% in 7 patients (22.6%) and 9 controls (25.7%)(P = 0.77).Conclusion: The haemodynamic response of ambulatory paediatric patients with a Fontan circulation to passive leg raising is like that of healthy controls. Patients who did not respond were similarly affected as healthy controls. Whether the haemodynamic response is different in critically ill patients warrants further investigation.Trail registration: The Netherlands National Trial Register (NTR), Trial: NL6415; date of registration 20-07-2017; Trial information: https://www.trialregister.nl/trial/6415.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis
    Preau, Sebastien
    Saulnier, Fabienne
    Dewavrin, Florent
    Durocher, Alain
    Chagnon, Jean-Luc
    CRITICAL CARE MEDICINE, 2010, 38 (03) : 819 - 825
  • [22] Bioreactance-based passive leg raising test can predict fluid responsiveness in patients with sepsis
    C Hu
    H Tong
    G Cai
    J Teboul
    J Yan
    X Lv
    Q Xu
    J Chen
    Q Rao
    M Yan
    Critical Care, 19 (Suppl 1):
  • [23] PASSIVE LEG RAISING CAN PREDICT FLUID RESPONSIVENESS IN PATIENTS PLACED ON VENO-VENOUS EXTRA
    Zogheib, E.
    Guinot, P. G.
    Detave, M.
    Hubert, V.
    Badoux, L.
    Bernard, B.
    Urbina, B.
    Akinbusoye, O.
    Dupont, H.
    INTENSIVE CARE MEDICINE, 2011, 37 : S92 - S92
  • [24] Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis
    X Monnet
    J-L Teboul
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [25] Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis
    Xavier Monnet
    Paul Marik
    Jean-Louis Teboul
    Intensive Care Medicine, 2016, 42 : 1935 - 1947
  • [26] Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis
    Monnet, Xavier
    Marik, Paul
    Teboul, Jean-Louis
    INTENSIVE CARE MEDICINE, 2016, 42 (12) : 1935 - 1947
  • [27] Passive leg raising for assessment of volume responsiveness: a review
    Mesquida, Jaume
    Gruartmoner, Guillem
    Ferrer, Ricard
    CURRENT OPINION IN CRITICAL CARE, 2017, 23 (03) : 237 - 243
  • [28] Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients
    A Lafanechère
    F Pène
    C Goulenok
    A Delahaye
    V Mallet
    G Choukroun
    JD Chiche
    JP Mira
    A Cariou
    Critical Care, 10
  • [29] Does Fluid Administration Based on Fluid Responsiveness Tests such as Passive Leg Raising Improve Outcomes in Sepsis?
    Nugent, Kenneth
    Berdine, Gilbert
    Pena, Camilo
    CURRENT CARDIOLOGY REVIEWS, 2022, 18 (05) : 18 - 23
  • [30] Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients
    Lafanechere, A.
    Pene, F.
    Goulenok, C.
    Delahaye, A.
    Mallet, V.
    Choukroun, G.
    Chiche, J. D.
    Mira, J. P.
    Cariou, A.
    CRITICAL CARE, 2006, 10 (05):