Diagnostic Performance and Clinical Impact of Photon-Counting Detector Computed Tomography in Coronary Artery Disease

被引:0
|
作者
Sakai, Koshiro [1 ,2 ,3 ,4 ]
Shin, Doosup [1 ,2 ]
Singh, Mandeep [1 ,2 ]
Malik, Sarah [1 ,2 ]
Dakroub, Ali [1 ,2 ]
Sami, Zainab [1 ,2 ]
Weber, Jonathan [1 ,2 ]
Cao, J. Jane [1 ,2 ,5 ]
Parikh, Roosha [1 ,2 ,5 ]
Chen, Lu [1 ,2 ,5 ]
Sosa, Fernando [1 ,2 ]
Cohen, David J. [1 ,2 ]
Moses, Jeffrey W. [1 ,2 ]
Shlofmitz, Richard A. [1 ,2 ]
Collet, Carlos [3 ]
Shlofmitz, Evan [1 ,2 ]
Jeremias, Allen [1 ,2 ]
Khalique, Omar K. [1 ,2 ,5 ,6 ]
Ali, Ziad A. [1 ,2 ,6 ]
机构
[1] St Francis Hosp, Dept Cardiol, Roslyn, NY USA
[2] Heart Ctr, Roslyn, NY USA
[3] OLV Clin, Cardiovasc Ctr Aalst, Aalst, Belgium
[4] Showa Univ, Sch Med, Dept Med, Div Cardiol, Tokyo, Japan
[5] St Francis Hosp, Div Cardiovasc Imaging, Roslyn, NY USA
[6] New York Inst Technol, Old Westbury, NY USA
关键词
computed tomography; coronary artery disease; coronary computed tomography angiography; diagnosis; quantitative coronary angiography; ANGIOGRAPHY; SOCIETY; CT;
D O I
10.1016/j.jacc.2024.10.069
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Photon-counting detector-computed tomography (PCD-CT) has emerged as a promising technology, offering improved spatial resolution. OBJECTIVES This study aimed to evaluate the clinical impact and diagnostic performance of PCD-CT vs conventional energy-integrating detector computed tomography (EID-CT) for obstructive coronary artery disease (CAD). METHODS From 2022 to 2023, we retrospectively identified 7,833 consecutive patients who underwent clinically indicated coronary computed tomography angiography (CCTA) at a single center, with either PCD-CT (n = 3,876; NAEOTOM Alpha [Siemens Healthineers]) or EID-CT (n = 3,957; Revolution Apex 256 [GE HealthCare] or Aquilion ONE ViSION 320 [Canon Medical Systems]) scanners. Subsequent invasive coronary angiography (ICA) and percutaneous or surgical revascularization were performed as part of routine clinical care. Among those referred for ICA after coronary CTA, the presence of obstructive CAD in each vessel was determined by coronary CTA (severe stenosis on visual assessment per the Coronary Artery Disease Reporting and Data System) and ICA (>= 50% diameter stenosis on quantitative coronary angiography) in a blinded fashion. The diagnostic performance of EID-CT and PCD-CT was compared by using quantitative coronary angiography as the reference standard. RESULTS Patients who underwent PCD-CT were less frequently referred to subsequent ICA than those undergoing EID-CT (9.9% vs 13.1%; P < 0.001). Among those who underwent ICA, revascularization was more frequently performed in the PCD-CT group than in the EID-CT group (43.4% vs 35.5%; P = 0.02). In the vessel-level analysis (n = 1,686), specificity (98.0% vs 93.0%; P < 0.001), positive predictive value (83.3% vs 63.0%; P = 0.002), and diagnostic accuracy (97.2% vs 92.8%; P < 0.001) were improved by PCD-CT. Sensitivity (90.9% vs 90.7%; P = 0.95) and negative predictive value (98.9% vs 98.7%; P = 0.83) for obstructive CAD were similar between the PCD-CT and EID-CT groups, respectively. CONCLUSIONS PCD-CT exhibited excellent diagnostic performance for detecting obstructive CAD. Compared with patients undergoing conventional EID-CT, fewer patients were referred to ICA after PCD-CT, but those referred were more likely to undergo revascularization. (JACC. 2025;85:339-348) (c) 2025 by the American College of Cardiology Foundation.
引用
收藏
页码:339 / 348
页数:10
相关论文
共 50 条
  • [31] Value of Ultrahigh-Resolution Photon-Counting Detector Computed Tomography in Cardiac Imaging
    Kravchenko, Dmitrij
    Hagar, Muhammad Taha
    Vecsey-Nagy, Milan
    Tremamunno, Giuseppe
    Szilveszter, Balint
    Vattay, Borbala
    Zsarnoczay, Emese
    Beke, Samuel
    Maurovich-Horvat, Pal
    Emrich, Tilman
    Varga-Szemes, Akos
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2025, 42 (02):
  • [32] Quantitative cartilage imaging using spectral photon-counting detector based computed tomography
    Endran, Kishore Raj
    Tao, Shengzhen
    Benike, Amy
    Leng, Shuai
    McCollough, Cynthia
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [33] Spiral breast computed tomography with a photon-counting detector (SBCT): The future of breast imaging?
    Wetzl, Matthias
    Dietzel, Matthias
    Ohlmeyer, Sabine
    Uder, Michael
    Wenkel, Evelyn
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 157
  • [34] Spectral Photon-Counting Computed Tomography for Coronary Stent Imaging Evaluation of the Potential Clinical Impact for the Delineation of In-Stent Restenosis
    Bratke, Grischa
    Hickethier, Tilman
    Bar-Ness, Daniel
    Bunck, Alexander Christian
    Maintz, David
    Pahn, Gregor
    Coulon, Philippe
    Si-Mohamed, Salim
    Douek, Philippe
    Sigovan, Monica
    INVESTIGATIVE RADIOLOGY, 2020, 55 (02) : 61 - 67
  • [35] Feasibility study of portable multi-energy computed tomography with photon-counting detector for preclinical and clinical applications
    Lee, Chang-Lae
    Hong, Key Jo
    Kim, Namwoo
    Han, Kwanhee
    Kim, Dongkyu
    Jung, Hoe-Su
    Lee, Sangmin
    Park, Junyoung
    Lee, Kyoung-Yong
    Lee, Jee Eun
    Choi, Yuna
    Cho, Minkook
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [36] Feasibility study of portable multi-energy computed tomography with photon-counting detector for preclinical and clinical applications
    Chang-Lae Lee
    Key Jo Hong
    Namwoo Kim
    Kwanhee Han
    Dongkyu Kim
    Hoe-Su Jung
    Sangmin Lee
    Junyoung Park
    Kyoung-Yong Lee
    Jee Eun Lee
    Yuna Choi
    Minkook Cho
    Scientific Reports, 11
  • [37] Imaging performance of phase-contrast breast computed tomography with synchrotron radiation and a CdTe photon-counting detector
    Sarno, A.
    Mettivier, G.
    Golosio, B.
    Oliva, P.
    Spandre, G.
    Di Lillo, F.
    Fedon, C.
    Longo, R.
    Russo, P.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (05): : 681 - 690
  • [38] Photon-Counting Computed Tomography for Coronary Stent Imaging In Vitro Evaluation of 28 Coronary Stents
    Petritsch, Bernhard
    Petri, Nils
    Weng, Andreas M.
    Petersilka, Martin
    Allmendinger, Thomas
    Bley, Thorsten A.
    Gassenmaier, Tobias
    INVESTIGATIVE RADIOLOGY, 2021, 56 (10) : 653 - 660
  • [39] Photon-Counting Computed Tomography in Atherosclerotic Plaque Characterization
    Cau, Riccardo
    Saba, Luca
    Balestrieri, Antonella
    Meloni, Antonella
    Mannelli, Lorenzo
    La Grutta, Ludovico
    Bossone, Eduardo
    Mantini, Cesare
    Politi, Carola
    Suri, Jasjit S.
    Cavaliere, Carlo
    Punzo, Bruna
    Maffei, Erica
    Cademartiri, Filippo
    DIAGNOSTICS, 2024, 14 (11)
  • [40] New contrast agents for photon-counting computed tomography
    Sawall, Stefan