Novel non-invasive and quantitative assessment of the renal function of transplanted kidneys using Doppler ultrasonography with the vascular index of superb microvascular imaging

被引:0
|
作者
Bae, Sung Hwan [1 ]
Lee, Eun Ji [1 ]
Hwang, Jiyoung [1 ]
Hong, Seong Sook [1 ]
Chang, Yun-Woo [1 ]
Nam, Boda [1 ]
机构
[1] Soonchunhyang Univ, Soonchunhyang Univ Seoul Hosp, Coll Med, Dept Radiol, 59 Daesagwan Ro, Seoul 04401, South Korea
关键词
Ultrasonography; Color Doppler ultrasonography; Kidney transplantation; Glomerular filtration rate; POWER DOPPLER; ULTRASOUND; COMPLICATIONS;
D O I
10.14366/usg.24176
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study assessed the reproducibility and clinical value of the vascular index (VI), derived from superb microvascular imaging (SMI) using Doppler ultrasonography, for evaluating renal function in transplanted kidneys. Methods: This retrospective study included 63 renal transplant patients who underwent grayscale and Doppler ultrasonography with SMI from January 2022 to February 2023. The VI of the transplanted kidneys was measured using three methods (VIbox, VIF1, VIF2). The VI was compared across chronic kidney disease (CKD) groups categorized by estimated glomerular filtration rate (eGFR) and Kidney Disease: Improving Global Outcomes (KDIGO) CKD risk groups based on eGFR and albuminuria. The correlation between VI and renal function was evaluated. Univariate and multivariate linear regression analyses were used to identify predictors of eGFR. Results: Significant differences in VI were observed among CKD groups based on eGFR (VIbox, P=0.001; VIF1, P<0.001; VIF2, P<0.001) and KDIGO CKD groups based on eGFR and albuminuria (VIbox, P=0.039; VIF1, P=0.001; VIF2, P<0.001). VIF1 and VIF2 demonstrated moderate/ high correlations with eGFR (r=0.627, P<0.001 and r=0.657, P<0.001, respectively) and serum creatinine (r=-0.626, P<0.001 and r=-0.649, P<0.001, respectively). VIbox moderately correlated with eGFR (r=0.445, P<0.001). Multivariate regression identified the urine albumincreatinine ratio (ACR) (adjusted odds ratio [aOR], 1.122; 95% confidence interval [CI],-0.007 to, 0.000; P=0.030) and VIF2 (aOR, 1.114; 95% CI, 0.466 to 1.235; P<0.001) were independently associated with eGFR. Conclusion: The VI measured by drawing a region of interest along the border of the transplanted kidney in SMI (VIF2) is highly reproducible and correlates well with eGFR. Both VIF2 and ACR independently predict eGFR.
引用
收藏
页码:160 / 169
页数:10
相关论文
共 50 条
  • [41] Non-invasive assessment of arterial distension waveforms using gradient-based Hough transform and power Doppler ultrasound imaging
    S. -M. Wu
    Y. -W. Shau
    F. -C. Chong
    F. -J. Hsieh
    Medical and Biological Engineering and Computing, 2001, 39 : 627 - 632
  • [42] Non-invasive Renal Denervation Using Externally Delivered Focused Ultrasound: Early Experience Using Doppler based Imaging Tracking and Targeting for Treatment
    Ormiston, John A.
    Anderson, Thomas
    Brinton, Todd J.
    Dawood, Omar
    Gertner, Michael
    Kay, Patrick
    Neuzil, Petr
    Starek, Zdenek
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B121 - B121
  • [43] Reactive hyperemia peripheral arterial tonometry, a novel non-invasive index of peripheral vascular function, is attenuated in patients with coronary endothelial dysfunction
    Bonetti, PO
    Pumper, GM
    Higano, ST
    Holmes, DR
    Lerman, A
    CIRCULATION, 2002, 106 (19) : 579 - 579
  • [44] Right ventricular impairment in patients with chronic respiratory failure on home oxygen therapy - Non-invasive assessment using a new Doppler index
    Yamaguchi, K
    Miyahara, Y
    Yakabe, K
    Kiya, T
    Nakatomi, M
    Shikuwa, M
    Kohno, S
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 1998, 26 (05) : 239 - 247
  • [45] ASSESSMENT OF INDIVIDUAL RENAL-FUNCTION IN CHILDREN USING TC-99M-DTPA - NON-INVASIVE METHOD
    KAINER, G
    MCLLVEEN, B
    HOSCHL, R
    ROSENBERG, AR
    AUSTRALIAN PAEDIATRIC JOURNAL, 1979, 15 (03): : 208 - 208
  • [46] NON-INVASIVE DIAGNOSIS AND ASSESSMENT OF AORTIC-VALVE DISEASE AND EVALUATION OF AORTIC PROSTHESIS FUNCTION USING ECHO PULSED DOPPLER VELOCIMETRY
    VEYRAT, C
    CHOLOT, N
    ABITBOL, G
    KALMANSON, D
    BRITISH HEART JOURNAL, 1980, 43 (04): : 393 - 413
  • [47] In vitro accuracy and non-invasive strain measurements of the antral muscle layer using a novel Doppler ultrasound strain rate imaging method
    Gilja, OH
    Matre, K
    Ahmed, AB
    Heimdal, A
    Hausken, T
    Gregersen, H
    Odegaard, S
    GASTROENTEROLOGY, 2003, 124 (04) : A673 - A673
  • [48] Extracorporeal non-invasive assessment of the hepatobiliary function using novel bile acid derivatives with near-infrared fluorescence
    Temprano, Alvaro
    Sanchez de Blas, Beatriz
    Espinosa-Escudero, Ricardo A.
    Cives, Candela
    Lozano, Elisa
    Briz, Oscar
    Perez-Melero, Concepcion
    Bermejo, Francisco
    Romero, Marta
    Marin, Jose
    JOURNAL OF HEPATOLOGY, 2021, 75 : S631 - S632
  • [49] Early impairment of left ventricular myocardial function after chronic abuse of anabolic androgenic steroids: non-invasive assessment by Doppler Myocardial and Strain Imaging
    D'andrea, A.
    Caso, P.
    Liccardo, B.
    De Corato, G.
    Salerno, G.
    Scarafile, R.
    Cuomo, S.
    Calabro, R.
    EUROPEAN HEART JOURNAL, 2006, 27 : 792 - 793
  • [50] Non-Invasive Assessment of Mechanical Property Changes with Cell Growth in a Polymer-Based Vascular Graft Using Ultrasound Elasticity Imaging
    Dutta, D.
    Lee, K. W.
    Allen, R.
    Yu, J.
    Wang, Y.
    Kim, K.