Biomechanical Effect of Ankle Ligament Injury in AO Type 44B2.1 Lateral Malleolus Fractures After Lateral Plate Fixation A Finite Element Analysis

被引:0
|
作者
Olcar, Haci Ali [1 ]
Mutu, Halil Burak [2 ]
Ozer, Alaettin [3 ]
Kuru, Tolgahan [4 ]
Aydin, Davut [1 ]
Korkmaz, Murat [1 ]
机构
[1] Yozgat Bozok Univ, Dept Orthopaed & Traumatol, Yozgat, Turkiye
[2] Tokat Gaziosmanpasa Univ, Dept Mech Engn, Tokat, Turkiye
[3] Yozgat Bozok Univ, Dept Mech Engn, Yozgat, Turkiye
[4] Canakkale Onsekiz Mart Univ, Dept Orthopaed & Traumatol, Canakkale, Turkiye
关键词
LAUGE-HANSEN CLASSIFICATION; SYNDESMOSIS; MECHANISM; ANATOMY; ADULTS;
D O I
10.7547/22-214
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distal fibula fractures at the ankle level are common and are usually accompanied by ligament injuries. This study aims to evaluate the effects of ankle ligament ruptures on ankle joints, fracture instability, and plate stress after distal fibula fracture fixed with a plate created by finite element analysis modeling and loading applied to ligament rupture models that may accompany this fracture. Methods: A finite element model consisting of three-dimensional fibula, tibia, foot bones, and ankle ligaments was designed to investigate the effects of ligament injuries accompanying plate-detected AO type 44B2.1 fractures on fracture detection, fixation material, and ankle joints. Then, the results were evaluated by modeling ligament rupture in six different ways. Results: In the modeling where the deltoid and talofibular ligaments are broken together, instability is highest in the ankle (2.31 mm) and fracture line (0.15 mm). The rupture of the anterior and posterior tibiofibular ligaments associated with syndesmosis caused less instability in the fracture and ankle than the single-ligament rupture models of both the deltoid and talofibular ligaments. Conclusions: In the finite element modeling of AO type 44B2.1 fractures detected with plate, the importance and potential effects of often-overlooked ankle ligament injuries are pointed out. Note that when treating ankle injuries, the ankle should be treated as a whole, with both bone and soft tissue. In some cases, the fracture may represent the visible tip of the iceberg. (J Am Podiatr Med Assoc 114(4), 2024; doi:10.7547/22-214)
引用
收藏
页数:8
相关论文
共 33 条
  • [21] Weightbearing after combined medial and lateral plate fixation of AO/OTA 41-C2 bicondylar tibial plateau fractures: a biomechanical study
    Thamyongkit, Sorawut
    Abbasi, Pooyan
    Parks, Brent G.
    Shafiq, Babar
    Hasenboehler, Erik A.
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [22] Computational Mechanical Analysis of AO 44A1, 44B1, and 44C1 Fractures with Finite Element Modeling: Evaluation of Screw, Plate, and Kirschner Wire Fixation
    Olcar, Haci Ali
    Ozer, Alaettin
    Mutu, Halil Burak
    Yurdakul, Goker
    Kuru, Tolgahan
    Aydin, Davut
    Korkmaz, Murat
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2024, 114 (01)
  • [23] Comments on Lee et al.: Lateral fixation of AO type-B2 ankle fractures: the Acutrak plus compression screw technique
    Ajay Pal Singh
    Divesh Gulati
    Arun Pal Singh
    Subhash Mahajan
    Vipul Garg
    International Orthopaedics, 2010, 34 : 1361 - 1362
  • [24] Comments on Lee et al.: Lateral fixation of AO type-B2 ankle fractures: the Acutrak plus compression screw technique
    Singh, Ajay Pal
    Gulati, Divesh
    Singh, Arun Pal
    Mahajan, Subhash
    Garg, Vipul
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (08) : 1361 - 1362
  • [25] Complex AO type C3 distal femur fractures: Results after fixation with a lateral locked plate using modified swashbuckler approach
    Agrawal, Anuj
    Kiyawat, Vivek
    INDIAN JOURNAL OF ORTHOPAEDICS, 2017, 51 (01) : 18 - 27
  • [26] Complex AO type C3 distal femur fractures: Results after fixation with a lateral locked plate using modified swashbuckler approach
    Anuj Agrawal
    Vivek Kiyawat
    Indian Journal of Orthopaedics, 2017, 51 : 18 - 27
  • [27] Biomechanical assessment of single LISS versus double-plate osteosynthesis in the AO type 33-C2 fractures: A finite element analysis
    Zhang, Wei
    Li, Jiantao
    Zhang, Hao
    Wang, Menglin
    Li, Lianting
    Zhou, Jianfeng
    Guo, Hui
    Li, Yang
    Tang, Peifu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (12): : 2142 - 2146
  • [28] Finite element analysis of different medial fixation strategies in double-plate osteosynthesis for AO type 33-C2 Femoral fractures *
    Li, Meng
    Jiang, Yu
    Wang, Junsong
    Xu, Gaoxiang
    Wang, Daofeng
    Li, Jiantao
    Zhang, Wei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S86 - S94
  • [29] Finite element analysis of different medial fixation strategies in double-plate osteosynthesis for AO type 33-C2 Femoral fractures
    Li, Meng
    Jiang, Yu
    Wang, Junsong
    Xu, Gaoxiang
    Wang, Daofeng
    Li, Jiantao
    Zhang, Wei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S86 - S94
  • [30] Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: a finite element analysis
    Yang, Pan
    Zhang, Ying
    Liu, Jian
    Xiao, Jin
    Ma, Li Min
    Zhu, Chang Rong
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2015, 49 (02) : 203 - 209