An assessment of the inter-rater and intra-rater reliability of the modified Gordon pin infection classification system

被引:0
|
作者
Bafor, Anirejuoritse [1 ]
Skals, Regitze Gyldenholm [2 ]
Shen, Ming [3 ]
Iobst, Christopher A. [1 ]
Rahbek, Ole [4 ]
Kold, Soren [4 ]
Fridberg, Marie [4 ]
机构
[1] Nationwide Childrens Hosp, Ctr Limb Lengthening & Reconstruct, Dept Orthopaed, Columbus, OH 43205 USA
[2] Aalborg Univ Hosp Res Data & Biostat, Aalborg, Denmark
[3] Aalborg Univ, Dept Elect Syst, Aalborg, Denmark
[4] Aalborg Univ Hosp, Dept Orthopaed, Interdisciplinary Orthopaed, Aalborg, Denmark
来源
DIGITAL HEALTH | 2024年 / 10卷
关键词
Modified Gordon score; inter-rater reliability; pin-site infection; pin-site labeling; EXTERNAL FIXATION; GRADING SYSTEM; SITE INFECTION; COMPLICATIONS;
D O I
10.1177/20552076241277672
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objectives A grading system deployed for continuous at-home monitoring of pin sites would potentially increase the chances of early detection of pin-site infections and the commencement of early treatment. The first five grades of the Modified Gordon Pin Site Classification Scheme (MGS) meet the criteria for a visual-only, digital assessment-based grading system. The aim of this study was to assess the inter- and intra-rater reliability of the first five grades of the MGS from digital images.Methods We graded 1082 pin sites from 572 digital photographs of patients who underwent external fixator treatment for various conditions using the first five grades of the MGS classification scheme. Percent agreement and kappa values were calculated to determine the inter- and intra-rater agreement. Results were also grouped into two categories: "good" consisting of MGS grades 0-2 and "bad" made up of grades 3 and 4 for sensitivity analysis. We also analyzed reliability based on color only using MGS grades 0 and 2.Results A total of 843 of the 1082 pin sites were scored by all raters. There was moderate reliability between raters with a Fleiss kappa value of 0.48 [CI 0.45, 0.51]. The reliability remained moderate based on grouping into "good' versus "bad" and based on color with Fleiss kappa values of 0.48 [CI 0.45, 0.52] and 0.45 [CI 0.42, 0.49], respectively. Intra-rater reliability demonstrated substantial agreement with kappa values of 0.63.Conclusion Scoring pin sites from digital images with the MGS demonstrated only moderate inter-rater reliability. Modifying the use of digital photos is needed for at-home monitoring of pin sites.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Sunnybrook Facial Grading System: Intra-rater and Inter-rater Variabilities
    Cabrol, Camille
    Elarouti, Lea
    Montava, Anne-Laure
    Jarze, Sylvie
    Mancini, Julien
    Lavieille, Jean-Pierre
    Barry, Pauline
    Montava, Marion
    OTOLOGY & NEUROTOLOGY, 2021, 42 (07) : 1089 - 1094
  • [22] Inter-Rater and Intra-Rater Reliability of the Kansas University Sitting Balance Scale
    Franc, Ingrid A.
    Mauldin, Samantha
    Roberts, Magdalena
    Rosa-DiStefano, Gregoria
    OCCUPATIONAL THERAPY IN HEALTH CARE, 2023, 37 (04) : 595 - 605
  • [23] Inter-rater and intra-rater reliability of the extended TUG test in elderly participants
    Bedoya-Belmonte, Juan Jose
    Rodriguez-Gonzalez, Maria del Mar
    Gonzalez-Sanchez, Manuel
    Pitarch, Jose Miguel Barreda
    Galan-Mercant, Alejandro
    Cuesta-Vargas, Antonio I.
    BMC GERIATRICS, 2020, 20 (01)
  • [24] Inter-rater and Intra-rater Reliability of the Videofluoroscopic Dysphagia Scale with the Standardized Protocol
    Ingi Min
    Hyeonseong Woo
    Jae Yoon Kim
    Tae-Lim Kim
    Yookyung Lee
    Won Kee Chang
    Se Hee Jung
    Woo Hyung Lee
    Byung-Mo Oh
    Tai Ryoon Han
    Han Gil Seo
    Dysphagia, 2024, 39 : 43 - 51
  • [25] Validation of Inter-Rater and Intra-Rater Reliability of Remote Dielectric Sensing Measurement
    Hori, Masakazu
    Imamura, Teruhiko
    Fukuo, Atsuko
    Fukui, Takuya
    Koi, Takatoshi
    Ueno, Yohei
    Onoda, Hiroshi
    Tanaka, Shuhei
    Ushijima, Ryuichi
    Sobajima, Mitsuo
    Fukuda, Nobuyuki
    Ueno, Hiroshi
    Kinugawa, Koichiro
    INTERNATIONAL HEART JOURNAL, 2022, 63 (01) : 73 - 76
  • [26] Inter-Rater and Intra-Rater Reliability of Sonographic Median Nerve and Wrist Measurements
    Gonzalez-Suarez, Consuelo B.
    Buenavente, Ma Lorraine D.
    Cua, Ronald Christopher A.
    Fidel, Maria Belinda C.
    Cabrera, Jan-Tyrone C.
    Regala, Carina Fatima G.
    JOURNAL OF MEDICAL ULTRASOUND, 2018, 26 (01) : 14 - 23
  • [27] Introducing a new definition of a near fall: Intra-rater and inter-rater reliability
    Maidan, I.
    Freedman, T.
    Tzemah, R.
    Giladi, N.
    Mirelman, A.
    Hausdorff, J. M.
    GAIT & POSTURE, 2014, 39 (01) : 645 - 647
  • [28] The Scarbase Duo®: Intra-rater and inter-rater reliability and validity of a compact dual scar assessment tool
    Fell, Matthew
    Meirte, Jill
    Anthonissen, Mieke
    Maertens, Koen
    Pleat, Jonathon
    Moortgat, Peter
    BURNS, 2016, 42 (02) : 336 - 344
  • [29] Tibial speed of sound in extremely preterm infants: inter-rater and intra-rater reliability
    Lopez, M. Romero
    Tibe, C.
    Naik, M.
    Yu-Carr, M.
    Bachim, A.
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2025, 369
  • [30] Inter-rater and intra-rater reliability of a clinical protocol for measuring turnout in collegiate dancers
    Greene, Amanda
    Lasner, Andrea
    Deu, Rajwinder
    Oliphant, Seth
    Johnson, Kenneth
    PHYSIOTHERAPY THEORY AND PRACTICE, 2019, 35 (01) : 94 - 99