An assessment of the inter-rater and intra-rater reliability of the modified Gordon pin infection classification system

被引:0
|
作者
Bafor, Anirejuoritse [1 ]
Skals, Regitze Gyldenholm [2 ]
Shen, Ming [3 ]
Iobst, Christopher A. [1 ]
Rahbek, Ole [4 ]
Kold, Soren [4 ]
Fridberg, Marie [4 ]
机构
[1] Nationwide Childrens Hosp, Ctr Limb Lengthening & Reconstruct, Dept Orthopaed, Columbus, OH 43205 USA
[2] Aalborg Univ Hosp Res Data & Biostat, Aalborg, Denmark
[3] Aalborg Univ, Dept Elect Syst, Aalborg, Denmark
[4] Aalborg Univ Hosp, Dept Orthopaed, Interdisciplinary Orthopaed, Aalborg, Denmark
来源
DIGITAL HEALTH | 2024年 / 10卷
关键词
Modified Gordon score; inter-rater reliability; pin-site infection; pin-site labeling; EXTERNAL FIXATION; GRADING SYSTEM; SITE INFECTION; COMPLICATIONS;
D O I
10.1177/20552076241277672
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objectives A grading system deployed for continuous at-home monitoring of pin sites would potentially increase the chances of early detection of pin-site infections and the commencement of early treatment. The first five grades of the Modified Gordon Pin Site Classification Scheme (MGS) meet the criteria for a visual-only, digital assessment-based grading system. The aim of this study was to assess the inter- and intra-rater reliability of the first five grades of the MGS from digital images.Methods We graded 1082 pin sites from 572 digital photographs of patients who underwent external fixator treatment for various conditions using the first five grades of the MGS classification scheme. Percent agreement and kappa values were calculated to determine the inter- and intra-rater agreement. Results were also grouped into two categories: "good" consisting of MGS grades 0-2 and "bad" made up of grades 3 and 4 for sensitivity analysis. We also analyzed reliability based on color only using MGS grades 0 and 2.Results A total of 843 of the 1082 pin sites were scored by all raters. There was moderate reliability between raters with a Fleiss kappa value of 0.48 [CI 0.45, 0.51]. The reliability remained moderate based on grouping into "good' versus "bad" and based on color with Fleiss kappa values of 0.48 [CI 0.45, 0.52] and 0.45 [CI 0.42, 0.49], respectively. Intra-rater reliability demonstrated substantial agreement with kappa values of 0.63.Conclusion Scoring pin sites from digital images with the MGS demonstrated only moderate inter-rater reliability. Modifying the use of digital photos is needed for at-home monitoring of pin sites.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Measuring Essay Assessment: Intra-rater and Inter-rater Reliability
    Kayapinar, Ulas
    EURASIAN JOURNAL OF EDUCATIONAL RESEARCH, 2014, (57): : 113 - 135
  • [2] Assessment of the Human Factors Analysis and Classification System (HFACS): Intra-rater and inter-rater reliability
    Ergai, Awatef
    Cohen, Tara
    Sharp, Julia
    Wiegmann, Doug
    Gramopadhye, Anand
    Shappell, Scott
    SAFETY SCIENCE, 2016, 82 : 393 - 398
  • [3] Intra-rater and inter-rater reliability of the Empathic Communication Coding System
    Ju, Yu-Jeng
    Lee, Meng-Lin
    Chen, Jou-Chieh
    Wang, Yi-Ching
    Chen, Chih-Ping
    Tsai, Han-En
    Wu, Tzu-Yi
    Hsieh, Ching-Lin
    BRITISH JOURNAL OF OCCUPATIONAL THERAPY, 2025,
  • [4] Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®
    Mihalinec, Katja
    Martinez-Cepa, Carmen B.
    Zuil-Escobar, Juan C.
    Kejzar, Natasa
    Vauhnik, Renata
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [5] THE INTER-RATER AND INTRA-RATER RELIABILITY ANALYSIS OF WORKPLACE ERGONOMIC RISK ASSESSMENT
    Rohani, Jafri Mohd.
    Adeyemi, Ademola James
    Abd Aziz, Roseni
    Rani, Mat Rebi Abdul
    JURNAL TEKNOLOGI, 2018, 80 (01): : 53 - 59
  • [6] Inter-rater and intra-rater reliability of the current assessment model and tools for laparoscopic suturing
    Wei, Chin-Hung
    Shen, Shih-Chiang
    Duh, Yih-Cherng
    Tsai, Kuei-Yen
    Chen, Hsin-An
    Huang, Shih-Wei
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (09): : 6586 - 6591
  • [7] Inter-rater and intra-rater reliability of the current assessment model and tools for laparoscopic suturing
    Chin-Hung Wei
    Shih-Chiang Shen
    Yih-Cherng Duh
    Kuei‐Yen Tsai
    Hsin-An Chen
    Shih-Wei Huang
    Surgical Endoscopy, 2022, 36 : 6586 - 6591
  • [8] Optoelectronic plethysmography: Intra-rater and inter-rater reliability in healthy subjects
    Vieira, Danielle S. R.
    Hoffman, Mariana
    Pereira, Danielle A. G.
    Britto, Raquel R.
    Parreira, Veronica F.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2013, 189 (03) : 473 - 476
  • [9] INTER-RATER AND INTRA-RATER RELIABILITY OF UROFLOWMETRY INTERPRETATION IN ADULT WOMEN
    Rickey, Leslie M.
    Mueller, Elizabeth R.
    Newman, Diane K.
    Markland, Alayne D.
    Falke, Chloe
    Rudser, Kyle
    Lukacz, Emily S.
    JOURNAL OF UROLOGY, 2023, 209 : E519 - E519
  • [10] Inter-rater and intra-rater reliability of the airway diameter measured by sonography
    Gómez-Tamayo J.C.
    Puerta-Guarín J.I.
    Rojas-Camejo C.M.
    Caicedo J.P.
    Calvache J.A.
    Journal of Ultrasound, 2018, 21 (1) : 35 - 40