An outcome analysis of utilizing contrast-free near-infrared autofluorescence imaging in thyroid cancer surgery: a retrospective study

被引:1
|
作者
Bakkar, Sohail [1 ]
Allan, Mohammad [2 ]
Halaseh, Basem [3 ]
Chorti, Angeliki [4 ]
Papavramidis, Theodosis [4 ]
Donatini, Gianluca [5 ]
Miccoli, Paolo [6 ]
机构
[1] Hashemite Univ, Fac Med, Dept Gen & Specialized Surg, Zarqa 13133, Jordan
[2] Jordanian Minist Hlth Hosp, Dept Gen Surg, Amman, Jordan
[3] Abdulhadi Hosp, Dept Anesthesia & Crit Care, Amman, Jordan
[4] Aristotle Univ Thessaloniki AUTH, Univ Hosp Thessaloniki AHEPA, Propaedeut Surg Dept 1, Thessaloniki 5462, Greece
[5] Univ Poitiers, CHU Poitiers, Dept Gen & Endocrine Surg, Poitiers, France
[6] Univ Pisa, Dept Surg Med Pathol & Crit Care, I-56124 Pisa, Italy
关键词
Hypoparathyroidism; Thyroid cancer surgery; Near-infrared autofluorescence imaging; Parathyroid gland detection; Inadvertent parathyroid resection; Parathyroid autotransplantation;
D O I
10.1007/s13304-025-02123-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Hypoparathyroidism is the most common complication of thyroid surgery. The best way to assume normal parathyroid gland (PTG) function is to preserve them in situ, undamaged. Near-infrared autofluorescence (NIRAF)-imaging has been introduced as a potentially useful adjunct in thyroid surgery. Objective To assess the surgical outcomes of NIRAF-imaging utility in thyroid surgery. Methods The clinical records of patients who underwent surgery for papillary thyroid carcinoma (PTC) in a 7-month period were retrospectively reviewed. The primary endpoint was to assess NIRAF's impact on postoperative hypoparathyroidism. Secondary endpoints included its impact in preventing inadvertent PTG resection, time to resolution of postoperative hypoparathyroidism, and additional benefits in therapeutic central compartment neck dissection (tCCND). Results Fifty consecutive patients underwent surgery for PTC. Total thyroidectomy was performed in 42 patients. Whereas concomitant tCCND was performed in 8 patients. PTG-detection rate was 93% for NIRAF versus 87% for the surgeon (p = 0.04). NIRAF prevented inadvertent resection of 16 PTGs (p < 0.001). In tCCND, the detection rate of NIRAF was 100% versus 81% for the surgeon (p < 0.01). The rate of transient hypoparathyroidism applying NIRAF was 12% versus 15% (historical cohort) (p = 0.6). However, a significantly prompter resolution of hypoparathyroidism was demonstrated using NIRAF (average time of 2.7 weeks vs. 12.3 weeks; p < 0.0001). Conclusion Although NIRAF did not significantly minimize the overall risk of postoperative transient hypoparathyroidism, it demonstrated a trend toward improvement. It also led to prompter resolution of hypoparathyroidism and lowered the risk for inadvertent PTG resection. Therefore, NIRAF seems to be a promising surgical adjunct.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Role of near-infrared fluorescence imaging in head and neck cancer surgery: from animal models to humans
    Atallah, Ihab
    Milet, Clement
    Coll, Jean-Luc
    Reyt, Emile
    Righini, Christian Adrien
    Hurbin, Amandine
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2015, 272 (10) : 2593 - 2600
  • [42] Indocyanine green and near-infrared fluorescence imaging in minimally invasive gastric cancer surgery: a narrative review
    Yamauchi, Suguru
    Wu, Zehui
    Orita, Hajime
    Fedor, Caroline
    Yoshimoto, Yutaro
    Kubota, Akira
    Tsuda, Kenki
    Yube, Yukinori
    Kaji, Sanae
    Xu, Aman
    Mine, Shinji
    Fukunaga, Tetsu
    MINI-INVASIVE SURGERY, 2023, 7
  • [43] Near-Infrared Cerebral Oximetry to Predict Outcome After Pediatric Cardiac Surgery: A Prospective Observational Study
    Flechet, Marine
    Guiza, Fabian
    Vlasselaers, Dirk
    Desmet, Lars
    Lamote, Stoffel
    Delrue, Heidi
    Beckers, Marc
    Casaer, Michael P.
    Wouters, Pieter
    Van den Berghe, Greet
    Meyfroidt, Geert
    PEDIATRIC CRITICAL CARE MEDICINE, 2018, 19 (05) : 433 - 441
  • [44] Blood flow evaluation of reconstructed gastric tube in esophageal surgery using near-infrared imaging and retrospective time-intensity curve analysis
    Nao Yamamoto
    Hiroyuki Kitagawa
    Kazumasa Orihashi
    Keiichiro Yokota
    Tsutomu Namikawa
    Satoru Seo
    Langenbeck's Archives of Surgery, 409
  • [45] Blood flow evaluation of reconstructed gastric tube in esophageal surgery using near-infrared imaging and retrospective time-intensity curve analysis
    Yamamoto, Nao
    Kitagawa, Hiroyuki
    Orihashi, Kazumasa
    Yokota, Keiichiro
    Namikawa, Tsutomu
    Seo, Satoru
    LANGENBECKS ARCHIVES OF SURGERY, 2024, 409 (01)
  • [46] Dual-Triggered Near-Infrared Persistent Luminescence Nanoprobe for Autofluorescence-Free Imaging-Guided Precise Therapy of Rheumatoid Arthritis
    Wang, Ruoping
    Shi, Junpeng
    Zhang, Qian
    Peng, Qiang
    Sun, Xia
    Song, Liang
    Zhang, Yun
    ADVANCED SCIENCE, 2023, 10 (04)
  • [47] Methods for analysis of near-infrared (NIR) quenched-fluorescent contrast agents in mouse models of cancer
    Widen, John C.
    Tholen, Martina
    Yim, Joshua J.
    Bogyo, Matthew
    CHEMICAL TOOLS FOR IMAGING, MANIPULATING, AND TRACKING BIOLOGICAL SYSTEMS: DIVERSE METHODS FOR OPTICAL IMAGING AND CONJUGATION, 2020, 639 : 141 - 166
  • [48] Utilizing Near-Infrared Spectroscopy (NIRS) to Identify Pediatric Trauma Patients Needing Lifesaving Interventions (LSIs): A Retrospective Study
    Ashby, David W.
    Gourlay, David M.
    Balakrishnan, Binod
    Meyer, Michael T.
    Drendel, Amy L.
    PEDIATRIC EMERGENCY CARE, 2022, 38 (01) : E193 - E199
  • [49] Multimodal laparoscopic coincidence gamma imaging system for near-infrared fluorescence guided surgery: a preclinical study
    Song, Seong Hyun
    Hong, Seong Jong
    Lee, Ho Young
    Kang, Han Gyu
    Han, Young Been
    JOURNAL OF MEDICAL IMAGING, 2023, 10 (03)
  • [50] Spectral polarization imaging of human prostate cancer tissue using a near-infrared receptor-targeted contrast agent
    Pu, Y
    Wang, WB
    Tang, GC
    Zeng, F
    Achilefu, S
    Vitenson, JH
    Sawczuk, I
    Peters, S
    Lombardo, JM
    Alfano, RR
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2005, 4 (04) : 429 - 436