Novel Spectrophotometric Method for Robust Detection of Trace Copper and Cobalt in High-Concentration Zinc Solution

被引:0
|
作者
Zhou, Fengbo [1 ]
Wu, Bo [1 ]
Zhou, Jianhua [1 ]
机构
[1] Shaoyang Univ, Sch Informat Sci & Engn, Hunan Prov Key Lab Southwest, Hunan Acad Workstat, Shaoyang 422000, Peoples R China
来源
MOLECULES | 2024年 / 29卷 / 23期
基金
中国国家自然科学基金;
关键词
zinc hydrometallurgy; continuous wavelet transform; derivative spectrophotometry; multi-objective optimization; ultraviolet-visible spectroscopy; UV-VIS SPECTROSCOPY; PLASMON-INDUCED TRANSPARENCY; THEORETICAL-ANALYSIS; WAVELET TRANSFORM; DOSAGE FORM; HYDROMETALLURGY;
D O I
10.3390/molecules29235765
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In the purification process of zinc hydrometallurgy, the spectra of copper and cobalt seriously overlap in the whole band and are interfered with by the spectra of zinc and nickel, which seriously affects the detection results of copper and cobalt in zinc solutions. Aiming to address the problems of low resolution, serious overlap, and narrow characteristic wavelengths, a novel spectrophotometric method for the robust detection of trace copper and cobalt is proposed. First, the Haar, Db4, Coif3, and Sym3 wavelets are used to carry out the second-order continuous wavelet transform on the spectral signals of copper and cobalt, which improves the resolution of copper and cobalt and eliminates the background interference caused by matrix zinc signals and reagents. Then, the information ratio and separation degree are defined as optimization indexes, a multi-objective optimization model is established with the wavelet decomposition scale as a variable, and the non-inferior solution of multi-objective optimization is solved by the state transition algorithm. Finally, the optimal second-derivative spectra combined with the fine zero-crossing technique are used to establish calibration curves at zero-crossing points for the simultaneous detection of copper and cobalt. The experimental results show that the detection performance of the proposed method is far superior to the partial least squares and Kalman filtering methods. The RMSEPs of copper and cobalt are 0.098 and 0.063, the correlation coefficients are 0.9953 and 0.9971, and the average relative errors of copper and cobalt are 3.77% and 2.85%, making this method suitable for the simultaneous detection of trace copper and cobalt in high-concentration zinc solutions.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] A novel method for simultaneous determination of zinc, nickel, cobalt and copper based on UV-vis spectrometry
    Zhou, Fengbo
    Li, Changgeng
    Zhu, Hongqiu
    Li, Yonggang
    OPTIK, 2019, 182 : 58 - 64
  • [32] Spectral Pretreatment Method for Detection of Trace Cu2+ and Co2+ in Zinc Solution
    Zhu Hongqiu
    Chen Junming
    Yang Chunhua
    Li Yonggang
    Gong Juan
    ACTA OPTICA SINICA, 2019, 39 (01)
  • [33] Corrosion protection performance of graphene-modified zinc-rich epoxy coatings under high-temperature and high-concentration NaCl solution
    Jie Zhang
    Yuying Zheng
    Journal of Materials Science, 2023, 58 : 12202 - 12220
  • [34] Novel Method for Non-stationary Signals Via High-Concentration Time–Frequency Analysis Using SSTFrFT
    Guocheng Hao
    Juan Guo
    Yuxiao Bai
    Songyuan Tan
    Min Wu
    Circuits, Systems, and Signal Processing, 2020, 39 : 5710 - 5728
  • [35] Corrosion protection performance of graphene-modified zinc-rich epoxy coatings under high-temperature and high-concentration NaCl solution
    Zhang, Jie
    Zheng, Yuying
    JOURNAL OF MATERIALS SCIENCE, 2023, 58 (30) : 12202 - 12220
  • [36] Photoacoustic trace gas detection of ethylene in high-concentration methane background based on dual light sources and fiber-optic microphone
    Chen, Ke
    Zhang, Bo
    Guo, Min
    Chen, Yewei
    Deng, Hong
    Yang, Beilei
    Liu, Shuai
    Ma, Fengxiang
    Zhu, Feng
    Gong, Zhenfeng
    Yu, Qingxu
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 310
  • [37] Determination of trace of total silicon in high-purity copper by molybdosilicate spectrophotometric method after generation as silicon fluoride
    Yamaguchi, H
    Itoh, S
    Igarashi, S
    Kobayashi, T
    BUNSEKI KAGAKU, 2002, 51 (08) : 653 - 656
  • [38] Removal of High-Concentration CI Acid Orange 7 from Aqueous Solution by Zerovalent Iron/Copper (Fe/Cu) Bimetallic Particles
    Yuan, Yue
    Li, Huiqiang
    Lai, Bo
    Yang, Ping
    Gou, Min
    Zhou, Yuexi
    Sun, Guozhen
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (07) : 2605 - 2613
  • [39] Extended Kalman Filter Optimum Method for Determination of Trace Nickel Ion in High Concentrated Zinc Solution
    Zhou Feng-Bo
    Li Yong-Gang
    Zhu Hong-Qiu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 47 (08) : 1243 - 1248
  • [40] Clinical usefulness of a high-concentration calcium chloride solution method to correct the activated partial thromboplastin time in a high hematocrit model with heparin therapy
    Kanahara, Masaaki
    Harada, Haruhito
    Niiyama, Hiroshi
    Katoh, Atsushi
    Kai, Hisashi
    Ikeda, Hisao
    THROMBOSIS RESEARCH, 2012, 129 (02) : 215 - 217