Portable multiplexed ion-selective sensor for long-term and continuous irrigation water quality monitoring

被引:0
|
作者
Abdollahzadeh, Mojtaba [1 ,2 ]
Zhu, Yujie [1 ]
Bayatsarmadi, Bita [2 ]
Vepsalainen, Mikko [3 ]
Razmjou, Amir [4 ]
Murugappan, Krishnan [2 ]
Rodopoulos, Theo [2 ]
Asadnia, Mohsen [1 ]
机构
[1] Macquarie Univ, Sch Engn, Sydney, NSW 2109, Australia
[2] CSIRO, Mineral Resources, Private Bag 10, Clayton, Vic 3169, Australia
[3] VTT Tech Res Ctr Finland, VTT, POB 1000, FI-02044 Espoo, Finland
[4] Edith Cowan Univ, Sch Engn, 270 Joondalup Dr, Perth, WA 6027, Australia
关键词
Multiplex ion sensing; Potentiometric sensors; MOF; Sensor array; Environmental chemical engineering; Water quality monitoring; SOLID-CONTACT; POTENTIOMETRIC SENSORS; CARBON-BLACK; ELECTRODES; NITRATE; SYSTEM; GROWTH; ARRAY;
D O I
10.1016/j.compag.2024.109455
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
In agricultural contexts, the demand for continuous and precise measurement of multiple ions is crucial. While arrays of solid-contact ion-selective electrodes (SCEs) have been developed previously, there has been limited emphasis on their continuous and long-term monitoring of ions. Addressing this gap, our work introduces an innovative sensor array utilizing Ni-HAB MOF as an ion-to-electron transducer, enabling real-time detection of nitrate, potassium, and pH levels. The sensors exhibit exceptional stability, eliminating the need for frequent recalibration. For instance, the K+-selective sensor displays an unprecedentedly low potential drift of 0.05 mu V/h, surpassing existing solid-contact sensors by two orders of magnitude. Similarly, the pH sensor demonstrates a drift of 0.3 mu V/h, outperforming competitors by a factor of 100. The NO3- -selective sensor shows minimal drift at 0.5 mu V/h, surpassing comparable sensors by a factor of ten. Additionally, the K+-selective sensor features a sensitivity of 57.8 mV/dec and a LOD of 1.9 mu M, while the NO3- -selective sensor offers a sensitivity of 56.8 mV/ dec and a LOD of 6.23 mu M. Integrated into a portable array with wireless data transmission, this system enables real-time water quality monitoring in remote areas. Rigorous testing of the developed sensor array in a tailored complex agricultural solution confirms its selective response to target ions even in the presence of interfering ions. Importantly, pH fluctuations do not compromise the precision of the K+ and NO3- - selective sensors, highlighting the system's robustness in real-world agricultural settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Continuous long-term monitoring of ruminal pH
    Zosel, J.
    Kaden, H.
    Peters, G.
    Hoffmann, M.
    Rudisch, P.
    Jaekel, L.
    Lauckner, G.
    Grodrian, A.
    Guth, U.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 144 (02): : 395 - 399
  • [32] Paper-based ion-selective optodes for continuous sensing: Reversible potassium ion monitoring
    Kassal, Petar
    Sigurnjak, Marija
    Steinberg, Ivana Murkovic
    TALANTA, 2019, 193 : 51 - 55
  • [33] Irrigation and soil physical quality: an investigation at a long-term irrigation site
    Srinivasan, M. S.
    McDowell, R. W.
    NEW ZEALAND JOURNAL OF AGRICULTURAL RESEARCH, 2009, 52 (02) : 113 - 121
  • [34] Continuous Fatigue Crack Monitoring of Bridges: Long-Term Electrochemical Fatigue Sensor (LTEFS)
    Moshier, Monty A.
    Nelson, Levi
    Brinkerhoff, Ryan
    Miceli, Marybeth
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS 2016, 2016, 9799
  • [35] Calculated effects of membrane transport on the long-term response behavior of polymeric membrane ion-selective electrodes
    Morf, WE
    Badertscher, M
    Zwickl, T
    Reichmuth, P
    de Rooij, NF
    Pretsch, E
    JOURNAL OF PHYSICAL CHEMISTRY B, 2000, 104 (34): : 8201 - 8209
  • [36] A portable recorder for long-term fetal heart rate monitoring
    Ahmed, F
    Ibrahimy, MI
    Ali, MAM
    Zahedi, E
    MICROPROCESSORS AND MICROSYSTEMS, 2002, 26 (07) : 325 - 330
  • [37] Utilizing ion-selective electrodes for a water quality determination laboratory.
    Carvalho, KM
    Smoak, JM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U289 - U289
  • [38] LONG-TERM EFFECTS OF IRRIGATION WITH WASTE-WATER
    REYNOLDS, JH
    BRAUN, MO
    CAMPBELL, WF
    MILLER, RW
    ANDERSON, LR
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1980, 52 (04): : 672 - 687
  • [39] LONG-TERM PROJECTION OF WATER NEEDS FOR IRRIGATION IN THE USSR
    BEREZNER, AS
    SOVIET GEOGRAPHY REVIEW AND TRANSLATION, 1983, 24 (05): : 333 - 344
  • [40] Forward-Looking Roadmaps for Long-Term Continuous Water Quality Monitoring: Bottlenecks, Innovations, and Prospects in a Critical Review
    Huang, Yuankai
    Wang, Xingyu
    Xiang, Wenjun
    Wang, Tianbao
    Otis, Clifford
    Sarge, Logan
    Lei, Yu
    Li, Baikun
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2022, 56 (09) : 5334 - 5354