Energy and exergy analysis of a two-stage cascade vapor compression refrigeration system with modified system configuration

被引:0
|
作者
Patiluna, Dave Nygeil G. [1 ,2 ]
Donasco, Edgar Alan A. [2 ]
Hernandez, Noel M. [2 ]
Mamalias, Junil Bien A. [2 ]
Vina, Rommel R. [2 ]
机构
[1] Mindanao State Univ, Dept Mech Engn, Main Campus, Marawi City, Philippines
[2] Mindanao State Univ, Iligan Inst Technol MSU IIT, Dept Mech Engn, Iligan, Philippines
关键词
Cascade refrigeration system; Internal heat exchanger; Energy and exergy analysis; Ecop; Cop; Coefficient of performance; THERMODYNAMIC PERFORMANCE;
D O I
10.1016/j.ijrefrig.2024.10.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study proposes a modification to the two-stage cascade vapor compression refrigeration system by adding internal heat exchangers that function as subcoolers and desuperheater. The influence of each internal heat exchanger proposed on the exergy destruction rate, exergy efficiency, compressor power consumption, ECOP, and COP of the system was investigated. Additionally, various refrigerant combinations were considered as working fluids to evaluate which combination is the most suitable for the proposed system. Mathematical models based on the principles of thermodynamics were established in Engineering Equation Solver (EES), a software used for energy and exergy analysis. The results reveal that the addition of specific internal heat exchangers causes either an increase or decrease in overall system performance, depending on the type of refrigerant combination used. Consequently, there exists an optimal system configuration for each refrigerant combination. Compared with the conventional two-stage cascade refrigeration system, the optimal system configurations in the present study exhibited higher overall system performance. A maximum increase in exergy efficiency, ECOP, and COP of 7.31 %, 9.8 %, and 7.3 %, respectively, can be observed with the refrigerant combination R450A/ R404A. Additionally, the results of the exergy analysis identify that the HTC compressor, condenser, LTC compressor, and cascade condenser are the primary contributors to the exergy destruction rate within the system.
引用
收藏
页码:33 / 54
页数:22
相关论文
共 50 条
  • [1] Energy and exergy analysis of a two-stage cascade refrigeration system
    Mohammadi, S. M. Hojjat
    Ameri, Mehran
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2016, 37 (04): : 395 - 412
  • [2] ENERGY, EXERGY AND SUSTAINABILITY ANALYSIS OF TWO-STAGE VAPOUR COMPRESSION REFRIGERATION SYSTEM
    Chopra, Kapil
    Sahni, V.
    Mishra, R. S.
    JOURNAL OF THERMAL ENGINEERING, 2015, 1 (04): : 440 - 445
  • [3] A Review on Energy and Exergy Analysis of Two-Stage Vapour Compression Refrigeration System
    Chowdhury, Shounak
    Roy, Ranendra
    Mandal, Bijan Kumar
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2019, 27 (02)
  • [4] Energy and exergy analyses of a two-stage vapour compression refrigeration system
    Arora, Akhilesh
    Kaushik, S. C.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2010, 34 (10) : 907 - 923
  • [5] Exergy analysis of vapor compression refrigeration cycle with two-stage and intercooler
    Kilic, Bayram
    HEAT AND MASS TRANSFER, 2012, 48 (07) : 1207 - 1217
  • [6] Exergy analysis of vapor compression refrigeration cycle with two-stage and intercooler
    Bayram Kılıç
    Heat and Mass Transfer, 2012, 48 : 1207 - 1217
  • [7] Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration
    Sun, Zhili
    Wang, Yi'An
    Case Studies in Thermal Engineering, 2022, 39
  • [8] Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration
    Sun, Zhili
    Wang, Yi 'an
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 39
  • [9] Energy and exergy analysis of vapor compression-triple effect absorption cascade refrigeration system
    Agarwal, Shyam
    Arora, Akhilesh
    Arora, B. B.
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2020, 23 (03): : 625 - 641
  • [10] Exergy Analysis of a Vapor Compression Refrigeration System
    Hou, Xiao-chen
    Zhao, Guo-chang
    Song, Li-ping
    Wang, Yong
    Mao, Xiao-dong
    Peng, Da-wei
    2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 1817 - 1820