Two-dimensional, m-mode and doppler-derived echocardiographic parameters in standing healthy dorper sheep

被引:0
|
作者
de Moura, Rauane Sousa [1 ]
Landim, Beatriz Camara [2 ]
de Freitas, Daianny Pires [2 ]
Goncalves, Jessica Rocha [2 ]
Carvalho, Rosangela de Oliveira Alves [2 ]
Franco, Leandro Guimara [2 ]
机构
[1] Pontificia Univ Catolica Goias, Escola Ciencias Med & Vida, Goiania, Go, Brazil
[2] Univ Fed Goias, Escola Vet & Zootecnia, Goiania, Go, Brazil
关键词
Transthoracic echocardiogram; Doppler; Cardiac output; Lamb; Ovine; REFERENCE VALUES; RECOMMENDATIONS; INDEXES; HEART; QUANTIFICATION; LACTATION; STANDARDS;
D O I
10.1016/j.smallrumres.2024.107391
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Sheep are widely used in cardiovascular system research with emphasis in translational research for the echocardiographic diagnosis of heart diseases. Several studies have proposed reference values for the various echocardiographic parameters in healthy sheep. It is known that breed, age, sex and the technique used can contribute to changes in echocardiographic parameters, the reason for investigations in Dorper sheep echocardiography. The aim of study was to establish reference two-dimensional, m-mode and Doppler-derived echocardiographic parameters in standing Dorper sheep and to determine whether there is an influence of sex on echocardiographic parameters. Sixty-five pure Dorper lambs with 3-5 months of age, weighing 29.47 +/- 3.1 kg were used. The Doppler echocardiographic was conducted in a standing position through right parasternal windows for the long axis of the left ventricular outflow tract, short axis at the level of the papillary muscles, mitral valve, aortic valve, and left atrium; and left parasternal for the cranial long axis of the right ventricular outflow tract. Significant differences between males and females were noted in left ventricular free wall (LVFW) measurements during diastole (P = 0.03) and systole (P = 0.04), as well as in output by pulmonary artery flow (DCPA) values (P = 0.03). This study successfully established Doppler echocardiographic reference values for cardiac dimensions, left ventricular systolic function, and pulmonary artery flow in healthy lamb Dorper in a standing position.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] PRIMARY PULMONARY-HYPERTENSION - M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC FINDINGS
    BERGER, BC
    WALINSKY, P
    CAREY, P
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1983, 9 (02): : 187 - 195
  • [22] LEFT-VENTRICULAR MYXOMA - M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC FEATURES
    MAZER, MS
    HARRIGAN, PR
    AMERICAN HEART JOURNAL, 1982, 104 (04) : 875 - 877
  • [23] TWO-DIMENSIONAL AND M-MODE ECHOCARDIOGRAPHIC FINDINGS IN HYPERTENSIVE PREGNANT-WOMEN
    SANCHEZ, RA
    GLENNY, JE
    MARCO, E
    VOTO, LS
    LAPIDUS, AM
    IGLESIAS, GH
    MOLEDO, LV
    MARGULIES, M
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1986, 154 (04) : 910 - 913
  • [24] MITRAL-VALVE ANEURYSM - M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC FEATURES
    OQUENDO, I
    NAVA, J
    HERNANDEZCASAS, G
    SULBARAN, T
    GARCIA, L
    TEXAS HEART INSTITUTE JOURNAL, 1987, 14 (03) : 312 - 314
  • [25] QUANTIFICATION OF AORTIC-STENOSIS BY DOPPLER, M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    RICHARDS, K
    CRAWFORD, M
    CANNON, S
    GREENE, D
    HOEKENGA, D
    OROURKE, R
    CIRCULATION, 1980, 62 (04) : 99 - 99
  • [26] CLINICAL CORRELATES OF M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC MITRAL-VALVE PROLAPSE
    ZUGIBE, FT
    NANDA, NC
    CLINICAL RESEARCH, 1983, 31 (02): : A228 - A228
  • [27] Measurement of M-mode echocardiographic parameters in healthy adult Van cats
    Kayar, Abdullah
    Ozkan, Cumali
    Iskefli, Onur
    Kaya, Abdullah
    Kozat, Suleyman
    Akgul, Yakup
    Gonul, Remzi
    Or, Mehmet Erman
    JAPANESE JOURNAL OF VETERINARY RESEARCH, 2014, 62 (1-2) : 5 - 15
  • [28] Normal electrocardiographic and echocardiographic (M-mode and two-dimensional) values in Polish Landrace pigs
    Paslawska, Urszula
    Noszczyk-Nowak, Agnieszka
    Paslawski, Robert
    Janiszewski, Adrian
    Kiczak, Liliana
    Zysko, Dorota
    Nicpon, Jozef
    Jankowska, Ewa A.
    Szuba, Andrzej
    Ponikowski, Piotr
    ACTA VETERINARIA SCANDINAVICA, 2014, 56
  • [29] STATISTICAL COMPARISON OF THE M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC DIAGNOSIS OF FLAIL MITRAL LEAFLETS
    MINTZ, GS
    KOTLER, MN
    PARRY, WR
    SEGAL, BL
    AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02): : 435 - 435
  • [30] FALSE TENDONS IN THE LEFT-VENTRICLE - TWO-DIMENSIONAL AND M-MODE ECHOCARDIOGRAPHIC FINDINGS
    LINDVALL, K
    OLSSON, G
    SJOGREN, A
    ACTA MEDICA SCANDINAVICA, 1982, 212 (1-2): : 93 - 95