Potential of spectral imaging generated by contrast-enhanced dual-energy CT for lung cancer histopathological classification - A preliminary study

被引:0
|
作者
Sasaki, Tomoaki [1 ]
Oda, Shioto [1 ]
Kuno, Hirofumi [1 ]
Hiyama, Takashi [1 ]
Taki, Tetsuro [2 ]
Takahashi, Shugo [3 ]
Ishii, Genichiro [2 ]
Tsuboi, Masahiro [3 ]
Kobayashi, Tatsushi [1 ]
机构
[1] Natl Canc Ctr Hosp East, Dept Diagnost Radiol, 6-5-1 Kashiwanoha, Kashiwa, Chiba 2778577, Japan
[2] Natl Canc Ctr Hosp East, Dept Pathol & Clin Labs, 6-5-1 Kashiwanoha, Kashiwa, Chiba 2778577, Japan
[3] Natl Canc Ctr Hosp East, Dept Thorac Surg, 6-5-1 Kashiwanoha, Kashiwa, Chiba 2778577, Japan
关键词
Lung neoplasms; x-ray computed tomography; electron density image; adenocarcinoma; IODINE UPTAKE; ADENOCARCINOMA; EVALUATE;
D O I
10.1016/j.ejro.2024.100628
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The potential of spectral images, particularly electron density and effective Z-images, generated by dual- energy computed tomography (DECT), for the histopathologic classification of lung cancer remains unclear. This study aimed to explore which imaging factors could better reflect the histopathological status of lung cancer. Method: The data of 31 patients who underwent rapid kV-switching DECT and subsequently underwent surgery for lung cancer were analyzed. Virtual monochromatic images (VMIs) of 35 keV and 70 keV, virtual non-contrast images (VNC), iodine content images, electron density images, and effective Z-images were reconstructed for the following analyses: 1) correlation with the ratio of the lepidic growth pattern in the whole tumor and 2) comparisons with the four histological groups: well-differentiated adenocarcinoma (WDA), moderately differentiated adenocarcinoma (MDA), and poorly differentiated adenocarcinoma (PDA) and squamous cell carcinoma (SCC). Results: There were significant correlations between the ratio of lepidic growth pattern and 70 keV, 35 keV, VNC, and electron density images (r =-0.861, P < 0.001; r =-0.791, P < 0.001; r =-0.869, P < 0.001; r =-0.871, P <0.001, respectively). There were significant differences in the 70 keV, 35 keV, VNC, and electron density images in the Kruskal-Wallis test (P = 0.001, P = 0.006, P <0.001, P <0.001, respectively). However, there were no significant differences in iodine content or effective Z-images. Conclusions: Electron density images generated by spectral imaging may be better indicators of the histopathological classification of lung cancer. Clinical relevance: Electron density images may have an added value in predicting the histopathological classification of lung cancer.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Dual-energy subtraction for contrast-enhanced digital breast tomosynthesis
    Carton, Ann-Katherine
    Lindman, Karin
    Ullberg, Christer
    Francke, Tom
    Maidment, Andrew D. A.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [32] Gadoxetate Disodium enhanced spectral dual-energy CT for evaluation of cholangiocarcinoma: Preliminary data
    Thomas, John V.
    Bolus, David N.
    Jackson, Bradford E.
    Berland, Lincoln L.
    Yester, Michael
    Morgan, Desiree E.
    ANNALS OF MEDICINE AND SURGERY, 2016, 6 : 17 - 22
  • [33] Dual-Energy (Spectral) CT: Applications in Abdominal Imaging
    Blake, Michael A.
    RADIOGRAPHICS, 2011, 31 (04) : 1047 - 1050
  • [34] Initial Experience of Using Dual-Energy CT with an Iodine Overlay Image for Hand Psoriatic Arthritis: Comparison Study with Contrast-enhanced MR Imaging
    Fukuda, Takeshi
    Umezawa, Yoshinori
    Tojo, Shinjiro
    Yonenaga, Takenori
    Asahina, Akihiko
    Nakagawa, Hidemi
    Fukuda, Kunihiko
    RADIOLOGY, 2017, 284 (01) : 134 - 142
  • [35] Diagnostic performance of contrast-enhanced dual-energy spectral mammography (CESM): a retrospective study involving 644 breast lesions
    del Mar Travieso-Aja, Maria
    Maldonado-Saluzzi, Daniel
    Naranjo-Santana, Pedro
    Fernandez-Ruiz, Claudia
    Severino-Rondon, Wilsa
    Rodriguez Rodriguez, Mario
    Vega Benitez, Victor
    Perez-Luzardo, Octavio
    RADIOLOGIA MEDICA, 2019, 124 (10): : 1006 - 1017
  • [36] Diagnostic performance of contrast-enhanced dual-energy spectral mammography (CESM): a retrospective study involving 644 breast lesions
    María del Mar Travieso-Aja
    Daniel Maldonado-Saluzzi
    Pedro Naranjo-Santana
    Claudia Fernández-Ruiz
    Wilsa Severino-Rondón
    Mario Rodríguez Rodríguez
    Víctor Vega Benítez
    Octavio Pérez-Luzardo
    La radiologia medica, 2019, 124 : 1006 - 1017
  • [37] Differentiation of Lung Cancers From Inflammatory Masses with Dual-Energy Spectral CT Imaging
    Hou, Wei Shu
    Wu, Hua Wei
    Yin, Yan
    Cheng, Jie Jun
    Zhang, Qing
    Xu, Jian Rong
    ACADEMIC RADIOLOGY, 2015, 22 (03) : 337 - 344
  • [38] Contrast-enhanced dual-energy digital subtraction mammography: Optimization of the beam energy
    Kwan, ALC
    Boone, JM
    Le-Petross, H
    Lindfors, KK
    Seibert, JA
    Lewin, JM
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 1317 - 1321
  • [39] Dual-energy Computed Tomography Iodine Map for Breast Cancer: Comparison With Dynamic Contrast-enhanced Magnetic Resonance Imaging
    Goda, Noriko
    Funakoshi, Mahito
    Ono, Chiaki
    Mukaida, Hidenori
    Kaneko, Mayumi
    ANTICANCER RESEARCH, 2023, 43 (09) : 4133 - 4142
  • [40] Dual-energy contrast-enhanced digital mammography: initial clinical results
    Dromain, Clarisse
    Thibault, Fabienne
    Muller, Serge
    Rimareix, Francoise
    Delaloge, Suzette
    Tardivon, Anne
    Balleyguier, Corinne
    EUROPEAN RADIOLOGY, 2011, 21 (03) : 565 - 574