Incidence of atrial fibrillation in patients with an insertable cardiac monitor and symptomatic heart failure

被引:1
|
作者
Khan, Muhammad Shahzeb [1 ,2 ,3 ]
Zile, Michael R. [4 ,5 ]
Kahwash, Rami [6 ]
Sarkar, Shantanu [7 ]
Van Dorn, Brian [7 ]
Koehler, Jodi [7 ]
Franco, Noreli [7 ]
Gerritse, Bart [8 ]
Butler, Javed [1 ,9 ]
机构
[1] Baylor Scott & White Res Inst, Dallas, TX USA
[2] Baylor Coll Med, Temple, TX USA
[3] Heart Hosp, Plano, TX USA
[4] Med Univ South Carolina, Charleston, SC USA
[5] Ralph H Johnson Dept Vet Affairs Hlth Care Syst, Charleston, SC USA
[6] Ohio State Univ, Columbus, OH USA
[7] Medtronic, Mounds View, MN USA
[8] Medtron Bakken Res Ctr, Maastricht, Netherlands
[9] Univ Mississippi, Med Ctr, Jackson, MS USA
来源
关键词
Atrial fibrillation; Heart failure; Preserved and reduced LVEF; HFrEF; HFpEF; Insertable cardiac monitor; CATHETER ABLATION; ASSOCIATIONS; MORTALITY;
D O I
10.1002/ehf2.15180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimsWe aim to evaluate the incidence of atrial fibrillation (AF) in a large real-world cohort of patients implanted with an insertable cardiac monitor (ICM) who had a clinical history of symptomatic heart failure (HF) with reduced or preserved left ventricular ejection fraction (LVEF).MethodsPatients with an ICM and a history of HF events were identified from the Optum (R) de-identified Electronic Health Record dataset merged with an ICM device dataset collected during 2007-2021. All ICM-detected AF episodes that were available with >= 30-s of ECG at onset were adjudicated using artificial intelligence (AI model). Episodes with AI model probability of AF >= 0.9 were analysed. The Kaplan-Meier incidence of AF as a function of episode duration, history of AF, and LVEF were assessed.ResultsA total of 1020 patients with ICM were identified of whom 911 had >= 180 days of follow-up and were included. According to the AI model, 358 patients had 8407 episodes of true AF. Incidence of AF at 42 months was 45.6% (44.1% vs. 46.8% in reduced vs. preserved LVEF). Incidence of new-onset AF was 23.2% (23.3% vs. 22.2% in reduced vs. preserved LVEF) in patients with no clinical history of AF. Patients with new-onset AF had a higher HF event rate compared with patients who had no clinical history of AF and did not develop AF during follow-up [OR = 2.73 (1.47-5.09); P = 0.002]. Patients with preserved LVEF had more longer duration paroxysmal AF compared with those with reduced LVEF (44.5% vs. 33.9%, P = 0.02).ConclusionsAF was observed in almost half of patients with ICM and symptomatic HF. One-fourth of the patients had new onset AF and a higher rate of HF events compared with patients without AF. AF incidence was similar in patients with preserved and reduced LVEF.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Subcutaneously Insertable Cardiac Monitor for Atrial Fibrillation and HF Using ECG and Phonocardiography as Biomarkers
    Bang, Jaeson
    JACC-BASIC TO TRANSLATIONAL SCIENCE, 2023, 8 (04): : 380 - 382
  • [22] Unexpectedly low incidence of atrial fibrillation in heart failure patients treated by cardiac resynchronization therapy
    Leclercq, Christophe
    Pedeletti, Luigi
    Ritter, Philippe
    Van Gelder, Isabelle
    Stellbrink, Christoph
    Paul, Vince
    Daubert, Claude
    CIRCULATION, 2006, 114 (18) : 617 - 617
  • [23] A novel adaptive insertable cardiac monitor algorithm improves the detection of atrial fibrillation and atrial tachycardia in silico
    Saha, Sunipa
    Perschbacher, David
    Jones, Paul
    Frost, Kate
    Sharma, Arjun
    Mittal, Suneet
    Richards, Mark
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (09) : 2536 - 2543
  • [24] Atrial fibrillation burden characteristics in heart failure patients with reduced versus preserved ejection fraction as detected by insertable cardiac monitors
    Zile, M. R.
    Kahwash, R.
    Sarkar, S. Shantanu
    Koehler, J.
    Butler, J.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 11 - 12
  • [25] Cost-effectiveness Of Insertable Cardiac Monitors For Detection Of Undiagnosed Atrial Fibrillation In High-risk Patients With Heart Failure
    Witte, Klaus
    Lanctin, David
    Jones, Frank W. Grimsey
    Pouliot, Erika
    Sawyer, Laura M.
    Kasner, Scott
    JOURNAL OF CARDIAC FAILURE, 2022, 28 (05) : S99 - S99
  • [26] Accuracy of atrial fibrillation detection by an insertable cardiac monitor in patients undergoing catheter ablation: Results of the BioVAD study
    Assaf, Amira
    Theuns, Dominic A. M. J.
    Sakhi, Rafi
    Bhagwandien, Rohit E.
    Szili-Torok, Tamas
    Yap, Sing-Chien
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2022, 27 (03)
  • [27] Left Atrial Volume Index and PR Interval Are Independent Predictors of Atrial Fibrillation in Embolic Stroke Patients With Insertable Cardiac Monitor
    Ching, Marilou I.
    Zhang, Charles
    Vaughn, Caila
    Lail, Navdeep
    Leahy, Thomas
    Kandel, Amit
    Deline, Christopher
    Sawyer, Robert
    Franco, Carina Alfaro
    STROKE, 2018, 49
  • [28] Predictors of paroxsymal atrial fibrillation in embolic stroke patients with insertable cardiac monitor - a comprehensive stroke center experience
    Ching, M.
    Lail, N.
    Tirunagri, D.
    Magun, R.
    Kandel, A.
    Deline, C.
    Mowla, A.
    Sawyer, R.
    Franco, C. Alfato
    CEREBROVASCULAR DISEASES, 2017, 43
  • [29] Incidence and risk factors for symptomatic heart failure after catheter ablation of atrial fibrillation and atrial flutter
    Huang, Henry D.
    Waks, Jonathan W.
    Contreras-Valdes, Fernando M.
    Haffajee, Charles
    Buxton, Alfred E.
    Josephson, Mark E.
    EUROPACE, 2016, 18 (04): : 521 - 530
  • [30] Economic Impact of Increased Longevity in Insertable Cardiac Monitor Technology in Unexplained Syncope and Suspected Atrial Fibrillation Patients
    Witte, Klaus K.
    Sawyer, Laura M.
    Bermingham, Sarah L.
    Rinciog, Claudia
    Rosemas, Sarah C.
    Tsintzos, Stelios I.
    Reynolds, Matthew R.
    CIRCULATION, 2019, 140