Selective and sensitive electroanalytical biosensor based on Poly([Cu (H2O)2P2]I2)/GCE for the determination of esomeprazole in pharmaceutical formulations and biological fluid samples

被引:1
|
作者
Metto, Melaku [1 ,2 ]
Tesfaye, Alemu [1 ]
Atlabachew, Minaleshewa [1 ,3 ]
Abebe, Atakilt [1 ]
机构
[1] Bahir Dar Univ, Coll Sci, Dept Chem, Bahir Dar, Ethiopia
[2] Injibara Univ, Coll Nat & Computat Sci, Dept Chem, Injibara, Ethiopia
[3] Debark Univ, Coll Nat & Computat Sci, Dept Chem, Debark, Ethiopia
来源
关键词
Modified electrode; Esomeprazole; Sensing; Electrochemistry; Pharmaceutical formulations; CARBON-PASTE ELECTRODE; PROTON PUMP; LIQUID-CHROMATOGRAPHY; ACID; SENSOR; THERAPY; PHASE;
D O I
10.1016/j.ijoes.2024.100837
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The need to determine esomeprazole in pharmaceutical formulations and biological fluids with high accuracy arises to ensure proper dosage and follow-up on patient response. In the present investigation, Glassy Carbon Electrode (GCE) was modified by potentiodynamic electropolymerization of Diaquabis(1,10-phenanthroline copper (II) Iodide ([Cu(H2O)2P2]I2) on its surface with a fixed number of cycles. Cyclic voltammetry (CV) was used to characterize the voltammetric redox behavior of esomeprazole (ESO) on poly([Cu(H2O)2P2]I2)/GCE and the best reversible oxidative current response has been obtained. On the proposed electrode, the electrochemical activity of the ESO was enhanced at a peak intensity that was around 2.6 times higher than the bare one. The calibration curve for ESO at poly([Cu(H2O)2P2]I2)/GCE has a linear region for a concentration range of 0.01-200 mu M with the detection limit and limit of quantifications of 28.90 and 95.53, respectively and the associated standard deviation was 0.59 %. he current sensor has also been effectively used to detect esomeprazole in clinical fluid samples and pharmaceutical samples in a sensitive and selective approach. The outstanding recovery percentage in the range of 95.97-105.26 % in the presence of 50-300 % potential interferents indicated an excellent accuracy and selectivity of the proposed sensor towards ESO in the presence of potential interferants. The proposed method is simple, quick, stable, and effective for real sensor applications for esomeprazole sensing in different samples.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Sensitive Chemiluminescence Determination of Enoxacin by Flow-Injection Analysis in Biological Fluids and Pharmaceutical Formulation Using Copper(II) in Luminol-H2O2 System
    Alam, Al-Mahmnur
    Ferdous, Taslima
    Kamruzzaman, Mohammad
    Lee, Sang Hak
    Kim, Young Ho
    Suh, Jung Kee
    Chung, Hye Young
    Suh, Yeoun Suk
    SENSOR LETTERS, 2011, 9 (02) : 518 - 525
  • [22] Site-selective As-P substitution and hydrogen bonding in the crystal structure of philipsburgite, Cu5Zn((As,P)O4)2(OH)6•H2O
    Krivovichev, Sergey V.
    Zhitova, Elena S.
    Ismagilova, Rezeda M.
    Zolotarev, Andrey A.
    PHYSICS AND CHEMISTRY OF MINERALS, 2018, 45 (10) : 917 - 923
  • [23] Highly sensitive colorimetric determination of biothiols based on I--H2O2-3,3′,5,5′-tetramethylbenzidine system
    Lin, Jing
    Ni, Pengjuan
    Sun, Yujing
    Wang, Yilin
    Wang, Li
    Li, Zhuang
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 3472 - 3478
  • [24] Development of highly selective and sensitive electrochemical sensor for trace level determination of Cu2+ ions in different biological and Persian Gulf Algae samples
    Ashenagar, Azam
    Tarighat, Maryam Abbasi
    Abdi, Gholamreza
    SENSING AND BIO-SENSING RESEARCH, 2025, 47
  • [25] Two Related Copper(I) π-Complexes Based on 2-Allyl-5-(2-pyridyl)-2H-tetrazole Ligand: Synthesis and Structure of [Cu(2-apyt)NO3] and [Cu(2-apyt)(H2O)](BF4) Compounds
    Slyvka, Yurii
    Goreshnik, Evgeny
    Pokhodylo, Nazariy
    Pavlyuk, Oleksiy
    Mys'kiv, Marian
    ACTA CHIMICA SLOVENICA, 2016, 63 (02) : 399 - 405
  • [26] Neutron and ion beams in biological researchOn the scattering length density of proteins in H2O/D2O: Determination of H-D exchange using ES+I-MS
    W. G. Bouwman
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 264 : 271 - 275
  • [27] A chemiluminescence method for the determination of verapamil hydrochloride in pharmaceutical and environmental samples based on an Fe3O4 nanoparticles enhanced NaHCO3-H2O2 system
    Iranifam, Mortaza
    Hendekhale, Nasim Rahmati
    ANALYTICAL METHODS, 2017, 9 (47) : 6705 - 6712
  • [28] DNA hybridization biosensor using chitosan-carbon nanotubes composite film as an immobilization platform and [Cu(bpy)(MBZ)2(H2O)] (bpy=2,2′-bipyridine, MBZ = p-methylbenzoate) as a novel redox indicator
    Wang, Qingxiang
    Shi, Juanlan
    Ni, Jiancong
    Gao, Fei
    Gao, Feng
    Weng, Wen
    Jiao, Kui
    ELECTROCHIMICA ACTA, 2011, 56 (11) : 3829 - 3834
  • [29] Highly selective and sensitive determination of Cu2+ in drink and water samples based on a 1,8-diaminonaphthalene derived fluorescent sensor
    Sun, Tao
    Li, Yang
    Niu, Qingfen
    Li, Tianduo
    Liu, Yan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2018, 195 : 142 - 147
  • [30] Crystal structure of bis[μ-bis(diphenylphosphino)methane]-(μ-chloro)quinolinechlorodicopper(I) quinoline water (1:2:1), [Cu2(CH2(P(C6H5)2)2)2(C9H7N)Cl2]•(C9H7N)2•H2O
    Jin, Qiong-Hua
    Chen, Li-Min
    Dong, Jia-Cui
    Gao, Hong-Wei
    Yang, Liang
    Li, Pei-Zhou
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE-NEW CRYSTAL STRUCTURES, 2008, 223 (02): : 135 - 138