Studies of a Mechanically Pumped Two-Phase Loop with a Pressure-Controlled Accumulator Under Pulsed Evaporator Heat Loads

被引:0
|
作者
Truster, Nicholas [1 ]
Ervin, Jamie S. [2 ]
Roman, Abdeel [1 ]
Monfort, Jeff [3 ]
机构
[1] Air Force Res Lab, 2450 D St Bldg 20, Wright Patterson AFB, OH 45433 USA
[2] Univ Dayton, Dept Mech & Aerosp Engn, 300 Coll Pk, Dayton, OH 45469 USA
[3] Univ Dayton, Res Inst, Dept Mech & Aerosp Engn, 300 Coll Pk, Dayton, OH 45469 USA
关键词
two-phase flow; aircraft environmental control; mechanically pumped two-phase loop; pressure-controlled accumulator; PERFORMANCE;
D O I
10.3390/en17246347
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
As avionics become more power dense, electronic device cooling has become a significant barrier to aircraft integration. A mechanically pumped two-phase loop (MPTL) is a thermal subsystem that enables near isothermal evaporator operation, which is desirable for electronics cooling. The goal of this study was to integrate an MPTL with a pressure-controlled accumulator and model a predictive control technique to demonstrate improvements for transient, isothermal evaporator operation for MPTLs under pulsed evaporator heat loads. The model predictive controller enables active control of MPTL compressible volume, which has not been demonstrated for pulsed evaporator heat loads. Experimental data were collected to validate a representative numerical model. A pressure-controlled accumulator was added to an MPTL to experimentally characterize the system thermodynamic response for three pulsed evaporator heat loads. Two statistical methods were used to assess the numerical model agreement with the experimental results. Under pulsed evaporator heat loads, the mean percent error agreed within 3.45% and the mean average percent error agreed within 0.74% for the three pulsed evaporator heat loads. Finally, a traditional proportional-integral (PI) controller and an advanced model predictive controller were developed and integrated into the validated numerical model. Both control methods were evaluated for an expanded set of evaporator heat load profiles to analyze transient behavior. For evaporator heat profiles with high heat transfer rates, the model predictive controller can maintain a target +/- 2 K refrigerant temperature at the evaporator exit throughout the evaporator heat load duration, whereas the PI-controlled MPTL cannot. Through this work, active control of a pressure-controlled accumulator within an MPTL is shown to improve refrigerant isothermal (+/- 2 K) operation when compared to a traditional control technique.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Analytic characterization and operational limits of a hybrid two-phase mechanically pumped fluid loop based on the capillary pumped loop
    Ferreira, Julio
    Furst, Benjamin
    Daimaru, Takuro
    Sunada, Eric
    Kaviany, Massoud
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 183
  • [22] Study on the flow boiling characteristics of novel pin fin heat sinks in a two-phase mechanically pumped cooling loop
    Wang, Jiale
    Qi, Shaohuan
    Xu, Zhaohao
    Xu, Yu
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 60
  • [23] Experimental study on active disturbance rejection temperature control of a mechanically pumped two-phase loop
    Zhang, Chengbin
    Li, Guanru
    Sun, Li
    Chen, Yongping
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 129 : 1 - 10
  • [24] Numerical Simulations and Analyses of Mechanically Pumped Two-Phase Loop System for Space Remote Sensor
    Yu, Feng
    Meng, Qingliang
    ENERGIES, 2022, 15 (14)
  • [25] Test study of the operating performance of a mechanically pumped two-phase loop for a space remote sensor
    Meng Q.
    Zhao Z.
    Zhang H.
    Yang T.
    Zhao Y.
    Yu F.
    Zhongguo Kexue Jishu Kexue/Scientia Sinica Technologica, 2020, 50 (11): : 1474 - 1486
  • [26] Thermal vacuum test study of mechanically pumped two-phase loop for space remote sensor
    Meng Q.
    Zhao Z.
    Chen X.
    Zhu X.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2023, 49 (03): : 559 - 568
  • [27] Heat Transfer Characteristics inside an Evaporator of a Two-Phase Closed Loop Thermosyphon with Saw Tooth Ribbed Evaporator Surface
    Mahmood, S. L.
    Bagha, N.
    Akhanda, M. A. R.
    Islam, A. K. M. S.
    ADVANCED DESIGN AND MANUFACTURE TO GAIN A COMPETITIVE EDGE: NEW MANUFACTURING TECHNIQUES AND THEIR ROLE IN IMPROVING ENTERPRISE PERFORMANCE, 2008, : 111 - 120
  • [28] Closed-type pneumatic temperature control of a pressure-controlled loop heat pipe with a mechanically driven gas pressure controller
    Park, Cheongyong
    Joung, Wukchul
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 200
  • [29] Closed-type pneumatic temperature control of a pressure-controlled loop heat pipe with a mechanically driven gas pressure controller
    Park, Cheongyong
    Joung, Wukchul
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 200
  • [30] Thermodynamic modeling and optimization of hybrid linear concentrating photovoltaic and mechanically pumped two-phase loop system
    Li, Guanru
    Hua, Qingsong
    Sun, Li
    Khosravi, Ali
    Pabon, Juan Jose Garcia
    APPLIED ENERGY, 2023, 333