Comparative dosimetric assessment of combined treatment modalities in cervical cancer radiotherapy for optimal organ protection

被引:0
|
作者
Gazsi, Iozsef [1 ,2 ]
Marcu, Loredana G. [3 ,4 ]
机构
[1] West Univ Timisoara, Fac Phys, Timisoara 300223, Romania
[2] Emergency Cty Hosp, Oradea 410167, Romania
[3] Univ South Australia, UniSA Allied Hlth & Human Performance, Adelaide, SA 5001, Australia
[4] Univ Oradea, Fac Informat & Sci, Oradea 410087, Romania
关键词
3D-conformal radiotherapy; Intensity modulated radiotherapy; Volumetric modulated arc therapy; Brachytherapy; Organs at risk; Combined radiotherapy; Dosimetry; GUIDED ADAPTIVE BRACHYTHERAPY; INTRACAVITARY BRACHYTHERAPY; CLINICAL-OUTCOMES; VOLUME; CHEMORADIATION; PARAMETERS; CARCINOMA; APPLICATORS; EVOLUTION; HEAD;
D O I
10.1007/s00411-025-01113-7
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
External radiotherapy combined with internal radiotherapy in cervical cancer can provide a boost to the target volume to increase tumour control. At the same time internal radiotherapy protects neighboring organs. The aim of the present study was to dosimetrically compare three external beam radiotherapy techniques each combined with internal radiotherapy to evaluate the combination that offers the best organ protection. Treatment plans of 20 cervical cancer patients were created for external (including three-dimensional conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT)) as well as brachytherapy. The prescribed dose was 50 Gy in 25 fractions for external and 21 Gy in three fractions for internal radiotherapy. The following organs at risk (OARs) were evaluated: bladder, rectum, sigmoid and bowel bag. The study analyzed the results of different treatment combinations in terms of dosimetric values for various parameters. The D90 for the clinical target volume was around 120 Gy, with the highest value seen in 3D-CRT + BT (brachytherapy) combination at 120.59 Gy. For the bladder, the D2cc remained below the recommended threshold of 90 Gy, with the lowest value obtained for the BT + IMRT combination at 79.2 Gy. For the rectum, both D2cc and D1cc remained below the recommended threshold of 75 Gy for both parameters. All techniques fell below the recommended dose of 75 Gy for the sigmoid. For the intestine, there were statistically significant differences between BT + IMRT and BT + 3D-CRT. The VMAT technique showed superiority over IMRT in tumour volume coverage and several organ-at-risk parameters. Generally, intensity-modulated techniques showed dosimetric advantage over the traditional 3D technique in cervical cancer. In addition to providing better compliance and homogeneity, they provided superior protection for organs at risk, especially for bowel bag. It is concluded that the BT + IMRT technique provided the best protection for organs at risk based on the lowest OAR dosimetric values, especially for the intestine.
引用
收藏
页码:291 / 302
页数:12
相关论文
共 50 条
  • [31] Dosimetric comparison of IMRT vs. 3D conformal radiotherapy in the treatment of cancer of the cervical esophagus
    Fenkell, Louis
    Kaminsky, Inna
    Breen, Stephen
    Huang, Sophie
    Van Prooijen, Monique
    Ringash, Jolie
    RADIOTHERAPY AND ONCOLOGY, 2008, 89 (03) : 287 - 291
  • [32] Dosimetric comparison of different multileaf collimator leaves in treatment planning of intensity-modulated radiotherapy for cervical cancer
    Wang, Shichao
    Ai, Ping
    Xie, Li
    Xu, Qingfeng
    Bai, Sen
    Lu, You
    Li, Ping
    Chen, Nianyong
    MEDICAL DOSIMETRY, 2013, 38 (04) : 454 - 459
  • [33] RADICAL SURGERY COMBINED WITH RADIOTHERAPY IN TREATMENT OF CERVICAL CARCINOMA
    NIEMINEN, U
    MATTSSON, T
    WIDHOLM, O
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1974, 63 (02) : 134 - 140
  • [34] ASSESSMENT OF DIFFERENT TREATMENT MODALITIES IN STAGE IB2-IIA (BULKY) CERVICAL CANCER
    Musaev, A.
    Guzel, A.
    Gulec, U. Kucukgoz
    Vardar, M.
    Altintas, A.
    Gumurdulu, D.
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2013, 23 (08)
  • [35] Dosimetric Evaluation of Adaptive Stereotactic Radiotherapy Boost for Locally Advanced Cervical Cancer
    Pasetsky, J.
    Lavrova, E.
    Wang, Y. F.
    Riegel, A. C.
    Sedor, G. J.
    Chin, C.
    Ghiassi-Nejad, Z.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E174 - E174
  • [36] Dosimetric comparison of helical tomotherapy and intensity-modulated radiotherapy in cervical cancer
    Liu, J.
    Zhu, L.
    Li, S.
    Gao, S.
    Yan, J.
    Xie, L.
    Hou, Z.
    Zhou, X.
    Liu, B.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1005 - S1006
  • [37] Dosimetric impact of imaging modality (CT versus MRI) for cervical cancer radiotherapy
    Burke, S.
    Batumalai, V.
    Lim, K.
    Roach, D.
    Dinsdale, G.
    Mahoney, L.
    Jameson, M.
    Ochoa, C.
    Veera, J.
    Holloway, L.
    Vinod, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127
  • [38] VOLUMETRIC IMAGING BY MEGAVOLTAGE COMPUTED TOMOGRAPHY FOR ASSESSMENT OF INTERNAL ORGAN MOTION DURING RADIOTHERAPY FOR CERVICAL CANCER
    Collen, Christine
    Engels, Benedikt
    Duchateau, Michael
    Tournel, Koen
    De Ridder, Mark
    Bral, Samuel
    Verellen, Dirk
    Storme, Guy
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (05): : 1590 - 1595
  • [39] Dosimetric Analysis of Combined Intracavitary and Interstitial Needles Placement for Cervical Cancer
    Shiao, J.
    Patton, T.
    Holt, D.
    Robin, T.
    Fisher, C.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S154 - S155
  • [40] Brachytherapy Versus Stereotactic Body Radiotherapy for Cervical Cancer Boost: A Dosimetric Comparison
    Dahbi, Zineb
    Fadila, Kouhen
    Vinh-Hung, Vincent
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (04)