Heart failure due to arteriovenous fistula for hemodialysis. Presentation of two clinical cases

被引:0
|
作者
Bacigalupe, Juan [1 ]
Velazco, Maria paula [2 ]
Troncoso, Jorge [3 ]
Tajer, Carlos [1 ]
Mariani, Javier [1 ]
De Abreu, Maximiliano [1 ]
机构
[1] Hosp El Cruce, Serv Cardiol, Buenos Aires, Argentina
[2] Hosp El Cruce, Serv Ecocardiog, Buenos Aires, Argentina
[3] Hosp El Cruce, Serv Cirugia Cardiovasc, Buenos Aires, Argentina
关键词
hemodialysis; arteriovenous fistula; vascular access; heart failure; CARDIAC-OUTPUT; REDUCTION; ACCESS; TREAT; FLOW;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Arteriovenous fistulas for hemodialysis create a left- to-right shunt, resulting in an average 25% increase in cardiac output and subsequent remodeling of cardiac chambers. Some of these patients may develop high- output heart failure. In this report, we present two cases of heart failure associated with an arteriovenous fistula for hemodialysis, each showing distinct clinical outcomes following either its occlusion or cerclage. Drawing from existing medical literature, we explore potential causes that might account for the divergent clinical courses observed in these cases.
引用
收藏
页码:1011 / 1015
页数:5
相关论文
共 50 条
  • [11] Congestive heart failure due to adjuvant arteriovenous fistula in a femoroperoneal bypass
    Teittinen, K
    Albäck, A
    Biancari, F
    Lehtola, A
    Tukiainen, E
    Lepäntalo, M
    JOURNAL OF CARDIOVASCULAR SURGERY, 1999, 40 (04): : 571 - 572
  • [12] Revision using distal inflow for treatment of heart failure secondary to arteriovenous fistula for hemodialysis
    Parmar, C. D.
    Chieng, G.
    Abraham, K. A.
    Kumar, S.
    Torella, F.
    JOURNAL OF VASCULAR ACCESS, 2009, 10 (01): : 62 - 63
  • [13] Hight output heart failure due to arteriovenous fistula after an orthopedic surgery
    Lucas Celia Petersen, L.
    Salame, M.
    Goldani, M. A.
    Wanderley, S. V. G.
    Reichert, T. R.
    Drebes, C. V. E.
    Crecenzio, M.
    Jardim, J. S.
    Guaragna, J. C. V. C.
    Danzmann, J. C. V. C.
    EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 137 - 137
  • [14] Right heart failure due to arteriovenous fistula after lumbar spine surgery
    Kwon, Seong Soon
    Park, Byoung-Won
    Lee, Min-Ho
    Goo, Dong Erk
    Nam, Bo Da
    KOREAN JOURNAL OF INTERNAL MEDICINE, 2020, 35 (04): : 1022 - 1023
  • [15] Gender related alterations of β-adrenoceptor mechanisms in heart failure due to arteriovenous fistula
    Dent, Melissa R.
    Tappia, Paramjit S.
    Dhalla, Naranjan S.
    JOURNAL OF CELLULAR PHYSIOLOGY, 2012, 227 (08) : 3080 - 3087
  • [16] Analysis of arteriovenous fistula failure in hemodialysis patients.
    Ding, Hong
    Gao, Di
    BIOMEDICAL RESEARCH-INDIA, 2016, 27 (02): : 396 - 400
  • [17] Infant Pneumonitis Due to a Tracheoesophageal Fistula: A Presentation of Two Autopsy Cases
    Tousia, Athina
    Platzas, Ioannis
    Goutas, Nikolaos
    Vlachodimitropoulos, Dimitrios
    Katsos, Konstantinos
    Kolentinis, Christoforos
    Piagkou, Maria
    Sakelliadis, Emmanouil I.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (12)
  • [18] Central venous catheters for hemodialysis. Cases of failure: Role of the nephrologist
    Joyeux, V
    NEPHROLOGIE, 2001, 22 (08): : 421 - 424
  • [19] A dural arteriovenous fistula with an unusual clinical presentation
    Intikhab, Osama
    Cristiano, Brian C.
    Carey, John P.
    Gailloud, Philippe H.
    INTERVENTIONAL NEURORADIOLOGY, 2023,
  • [20] ARTERIOVENOUS FISTULA FAILURE DUE TO TWO STRAIGHT SHUNTS FORMATION AT DRAINING VEIN
    Tong, YanQing
    Qi, WanLi
    Sun, Min
    AFRICAN JOURNAL OF TRADITIONAL COMPLEMENTARY AND ALTERNATIVE MEDICINES, 2013, 10 (03) : 541 - 542